Records from 2010 to 2016. Most recent: inspection, 6 April 2016.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 6
6 April 2016
In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6057987
27 October 2015
Deficiency Check · COC-MODU Annual
Physical examination · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 5753493
3 June 2014
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4879168
3 March 2014
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4810237
13 October 2010
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3869294
8 March 2010
COC-MODU Renew
Type not classified · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 3696415
Lifesaving › Launching Appliances › Winch
Issued 27 October 2015
Resolved
Lifeboat falls spool unevenly, slipping between previous turns. Before a unit leaves port and at all times during operation and transit, all lifesaving applainces should be in working order and ready for immediate use. [09 MODU Code 10.18.1]
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 4 January 2016
Resolved 14 March 2016
Resolution: deficiency resolved as all l/b winches were respooled by servicing company and letter/photos submitted by Captain of vessel
Navigation › Piloting/Steering › Maneuvering Information Fact Sheet
Issued 8 March 2010
Resolved
Provide Maneuvering Information with warning.
Action required: 15 - Rectify deficiencies by next port
Resolved 3 August 2011
Resolution: Verified during initial COC(c)-MODU
Documentation › Manuals/Policy Documentation › Steering Gear Changeover Instructions
Issued 8 March 2010
Resolved
Provide steering instructions and post at steering locations.
Action required: 15 - Rectify deficiencies by next port
Resolved 3 August 2010
Resolution: Verified during initial COC(c)-MODU
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 8 March 2010
Resolved
Disable locking capacity of the PFD storage boxes at the muster stations.
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Resolved 3 August 2010
Resolution: Verified during initial COC(c)-MODU
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 8 March 2010
Resolved
Provide Oil Transfer Procedures as required by 33CFR 155.720
Action required: 15 - Rectify deficiencies by next port
Resolved 3 August 2010
Resolution: Verified during initial COC(c)-MODU
Lifesaving › Lifeboat › Boarding Ladder
Issued 8 March 2010
Resolved
Provide adequate coverage for Jacob's ladders to board all liferafts.
Condition: Placed in Improper Service
Action required: 15 - Rectify deficiencies by next port
Resolved 3 August 2010
Resolution: Verified during initial COC(c)-MODU
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 8 March 2010
Resolved
Make OWS available for examination.
Action required: 705 - Other - as specified
Resolved 3 August 2010
Resolution: Verified during initial COC(c)-MODU
Fire Fighting › Semiportable CO2 Fire Extinguishers › Location
Issued 8 March 2010
Resolved
Provide proper storage for semi portable extinguishers on the heli-deck. Extinguishers can only be used in the upright position. Current stowage must be altered.
Condition: Placed in Improper Service
Action required: 15 - Rectify deficiencies by next port
Resolved 3 August 2010
Resolution: Verified during initial COC(c)-MODU
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 8 March 2010
Resolved
Provide COFR.
Action required: 15 - Rectify deficiencies by next port
Resolved 31 May 2011
Resolution: Vessel out of US waters
Fire Fighting › Fire Hydrants › Material
Issued 8 March 2010
Resolved
Provide evidence that the fire stations on the Upper and A decks internal to the accommodation spaces meet the intent of MODU Code 9.4.17.
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Resolved 3 August 2010
Resolution: Verified during initial COC(c)-MODU
Fire Fighting › Fixed Fire Detection System › Annual Inspection
Issued 8 March 2010
Resolved
Test fire and gas detectors as necessary to ensure the system is functioning. Vessel unable to provide testing medium during the course of this inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 3 August 2010
Resolution: Verified during initial COC(c)-MODU