VISHVAKARMAA

VISHVAKARMAA is a tank ship. The Coast Guard has recorded 4 inspections since 2019, most recently in May 2026, along with 5 deficiencies.

Records from 2019 to 2026. Most recent: inspection, 25 May 2026.

Built
Not recorded
Last inspected
25 May 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9387750
V7A5882
1056488
Flag
MARSHALL ISLANDS
Maury page id
psix-1056488

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspections, by type

Years with a record 4 calendar years (2019–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it47266 - Convention (Subpart B), Gross Ton
55800 - Dead Weight, Ton
55800 - Displacement, Ton
17539 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 4

25 May 2026 Administrative Inspection · COC-GAS Annual
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8380177
16 May 2025 COC-GAS Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8135761
7 December 2020 Ballast Water Examination · PSC B · Administrative Inspection · Deficiency Check · COC-GAS Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7106254
10 December 2019 COC-GAS Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6868831

Deficiency record · 5

07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 16 May 2025 Resolved
IN CARGO COMPRESSOR AND PUMP-ROOMS AND IN CARGO CONTROL ROOMS IF CONSIDERED GAS DANGEROUS, THE VENTILATION SHOULD BE OF THE NEGATIVE PRESSURE TYPE PSCO OBSERVED POSITIVE PRESSURE VENTILATION IN CARGO COMPRESSOR ROOM. 74 SOLAS (20) VII/13.1, 1993 IGC 12.1.5
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 May 2025
Resolved 16 May 2025
Resolution: PSCO OBSERVED SHIP'S CREW RESTORE NEGATIVE PRESSURE TO SPACE.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Resources and personnel
Issued 7 December 2020 Resolved
The Company should ensure that all personnel involved in the Company's safety management system have an adequate understanding of relevant rules, regulations, codes and guidelines. While conducting a test of the fixed gas detection system ships personnel utilized cargo as a sampling media. Procedure # DEG0014C ( monthly check of fixed gas system) states that span gas shall be used. (Def #4) Ship personnel stated that the master , C/O, 2/O, 3/O joined on the afternoon of the 27NOV2020. The off-signing members departed the morning of 29NOV2020. Company procedures for the relief of personnel outlined in TMM QA System manual 5.1.1(c) states that the crew shall be provided with proper familiarization of their duties in relation to the ISM Code. There is objective evidence discovered in an expanded ISM exam revealed the following non-conformity; the company failed to fully implement the requirements of the SMS as evident by def # 2,3,4. An internal audit is required with in 3 months. 74SOLAS(14) IX/3 ISM Code 6.4
Action required: 705 - Other - as specified
Due 7 March 2021
Resolved 1 February 2021
Resolution: Audit result: Based on the audit the ISM system was found well implemented and in the samples verified, one observation was issued, and no non-conformities were identified.
12 - Dangerous Goods › N/A - No Subsystem › Fire protection cargo deck area
Issued 7 December 2020 Resolved
The condition of the ship and its equipment should be maintained to conform with the provisions of the code to ensure that the ship will remain fir to proceed to sea without danger to the ship or persons onboard. PSCO observed 3 inch X 1/2 inch rupture in the deck water spray system. Hole was located in piping above cargo tank dome #1. PSCO observed rupture occur when deck water spray was activated during exam. 74solas(14) vii/13.1 IGC Code (1993) 1.5.3.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 1 June 2021
Resolved 27 December 2020
Resolution: The damaged pipe section was renewed. Recorded video of spray system under pressure, the photo of the replaced pipe and the master's statement dated 2020-12-27 confirmed that the ruptured pipe was replaced and tested satisfactorily.
12 - Dangerous Goods › N/A - No Subsystem › Fire protection cargo deck area
Issued 7 December 2020 Resolved
On ships carrying flammable or toxic products or both. A water spray system for cooling, fire prevention, and crew protection should be installed to cover exposed cargo tank domes, exposed on deck storage vessels for flammable or toxic products, cargo liquid and vapor discharge and loading manifolds and the area of their control valves, boundaries of cargo compressor rooms. PSCO observed inadequate coverage for tank dome 1,2,3 Port and Starboard manifold, deck tank, and above motor compressor room for deck water spray. Tanks 1 and 2 Port and Starboard manifold had 50% coverage. 74SOLAS (14) VII/13.1 IGC Code (1993) 11.3.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 7 December 2020
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 7 December 2020 Resolved
Gas detection equipment should be so designed that it may readily be tested. Testing and calibration should be carried out at regular intervals. Initial testing of the fixed gas detection system resulted in 106% LEL. Subsequent testing resulted in 56% and 60% LEL. The crew re-calibrated the system with 35% Span Gas , resulting in 33% LEL. 74SOLAS(14) VII/13.1 IGC Code 1993 13.6.6
Action required: 10 - Deficiency Rectified
Resolved 7 December 2020