MAURY USCG vessel records Sign in
← All vessels

F SPIRIT

F SPIRIT is a 1995 freight ship. The Coast Guard has recorded 14 inspections since 2000, most recently in September 2008, along with 28 deficiencies.

Records from 2000 to 2008. Most recent: inspection, 19 September 2008.

Built
1995
Last inspected
19 September 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9080170 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
MARSHALL ISLANDS
—
Maury page id
psix-10567

Inspections, by type

…with no type recorded9
Years with a record 6 calendar years (2000–2008)
The 14 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it7662 - Convention (Subpart B), Gross Ton
3570 - Convention (Subpart B), Net Ton
9457 - Dead Weight, Ton
13713 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 14

19 September 2008 Ballast Water Examination · PII Safety Exam · Deficiency Check · ISPS II Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3328356
5 July 2007 PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 2984638
21 July 2006 Deficiency Check
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 2723597
14 March 2006 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 2603355
22 June 2002 Annual Inspection · MARPOL Annex II Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1631772
24 November 2001 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 508591
11 October 2001 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 491673
8 October 2001 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 528923
24 September 2001 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 441255
31 August 2001 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 529309
9 August 2001 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 292688
21 July 2001 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 292536
11 June 2001 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 290766
26 June 2000 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 279375

Deficiency record · 28

Lifesaving › Inflatable Liferafts › Weak Link
Issued 19 September 2008 Resolved
Rig all liferafts to vessel with proper weak link connections prior to departure.
Action required: 705 - Other - as specified
Resolved 22 September 2008
Resolution: Obtained and installed weak liks to allow proper operation.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 5 July 2007 Resolved
Provide Vessel Response Plan for non tank vessel
Condition: Unknown
Due 1 August 2007
Resolved 19 September 2008
Construction/Loadline › Structures › Air Pipe
Issued 5 July 2007 Resolved
Vent pipe HFO severely wasted and broken completely from main deck. Make repairs to satisfaction of Class.
Condition: Improper/Lack of Maintenance
Due 1 August 2007
Resolved 19 September 2008
Engineering › Sea-water System (primary cooling) › Piping
Issued 5 July 2007 Resolved
Repair salt water supply line to MDE L/O heat exchanger to satisfaction of Class.
Condition: Improper/Lack of Maintenance
Due 1 August 2007
Resolved 19 September 2008
Navigation › Piloting/Steering › Coast Guard Light List
Issued 14 March 2006 Resolved
Provide Coast Guard Light List for Pacific south of Equator.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 14 May 2006
Resolved 21 July 2006
Resolution: Provided Light List for Pacific south of Equator.
Construction/Loadline
Issued 21 July 2001 Resolved
Repair or replace the packing in the stuffing box on number one ballest_x001C_ water pump. SOLAS 74/78 AMMENDED I/11
Condition: Unknown
Due 14 August 2001
Resolved 14 August 2001
Electrical
Issued 21 July 2001 Resolved
Vessels generator sets #1, #2 l/o and f/o drain lines, from the fuel injector and high PSI f/o pump were designed such to be drained to the bilge, which is a violation under 33CFR155.770. As of presentthere is a_x001C_ make shift arrangment to prevent that violation(continued in comments)
Condition: Unknown
Due 14 August 2001
Resolved 14 August 2001
Electrical
Issued 21 July 2001 Resolved
Electrical matting is not continous switchboard, and is missing matting_x001C_ behind switchboard. Matting required due to the fact that behind the_x001C_ switchboard is used as a passageway._x001C_ SOLAS 74/78 AMMENDED II-1/45/2
Condition: Unknown
Due 14 August 2001
Resolved 14 August 2001
Construction/Loadline
Issued 21 July 2001 Resolved
Number one salt water pump discharge piping at the flange weld, has a_x001C_ steady water stream leak which requires repair._x001C_ SOLAS 74/78 AMMENDED I/11
Condition: Unknown
Due 21 August 2001
Resolved 4 August 2001
Engineering
Issued 11 June 2001 Resolved
Repair cooling water leak on starboard aft section of main diesel engine tosatisfaction of Class. SOLAS 74 amended I/11.
Condition: Unknown
Due 16 August 2001
Resolved 16 August 2001
Construction/Loadline
Issued 11 June 2001 Resolved
Deck reference line needs to be contrasting color. ICLL 1966 reg 8.
Condition: Unknown
Due 4 August 2001
Resolved 4 August 2001
Fire Fighting
Issued 11 June 2001 Resolved
Make all doors in the stair tower self-closing and remove holdbacks. SOLAS 74 amended II-2/46 and 47.
Condition: Unknown
Due 4 August 2001
Resolved 4 August 2001
Lifesaving
Issued 11 June 2001 Resolved
Replace rotted line on ring buoys, 2nd deck. SOLAS 74 amended III/19.2.
Condition: Unknown
Due 4 August 2001
Resolved 4 August 2001
Lifesaving
Issued 11 June 2001 Resolved
Replace retro-reflective tape on the tops of lifeboats. SOLAS 74 amended III/30.2.7.
Condition: Unknown
Due 4 August 2001
Resolved 4 August 2001
Construction/Loadline
Issued 11 June 2001 Resolved
Replace gaskets as needed on watertight doors, first deck aft. ICLL 1966 reg 17 and 18.
Condition: Unknown
Due 4 August 2001
Resolved 4 August 2001
Engineering
Issued 11 June 2001 Resolved
Re-install #2 main diesel engine raw water cooling pump or prove class acceptance of it's abscence. SOLAS 74 amended I/11.
Condition: Unknown
Due 4 August 2001
Resolved 4 August 2001
Unknown
Issued 11 June 2001 Resolved
Clean/remove excessive oil from deck in steering gear space. 33CFR160.215.
Condition: Unknown
Due 4 August 2001
Resolved 4 August 2001
Navigation
Issued 11 June 2001 Resolved
Calibrate rudder angle indicator on bridge, four degree error to port. SOLAS 74 amended I/11.
Condition: Unknown
Due 4 August 2001
Resolved 4 August 2001
Electrical
Issued 11 June 2001 Resolved
Repair inoperative gauges on both #1 and #2 ship service generators. SOLAS74 amended I/11.
Condition: Unknown
Due 4 August 2001
Resolved 4 August 2001
Construction/Loadline
Issued 11 June 2001 Resolved
Prove proper operation of #2 ballast/bilge pump. SOLAS 74 amended II- 2/21.1.1.
Condition: Unknown
Due 4 August 2001
Resolved 4 August 2001
Documentation
Issued 11 June 2001 Resolved
Provide an oil discharge placard at the OWS and at the overboard discharge valve. 33CFR155.450.
Condition: Unknown
Due 4 August 2001
Resolved 4 August 2001
Unknown
Issued 11 June 2001 Resolved
Provide heat shielding for exposed turbo chargers of both ship's service generators. SOLAS 74 amended II-1/26.1.
Condition: Unknown
Due 4 August 2001
Resolved 4 August 2001
Fire Fighting
Issued 11 June 2001 Resolved
Provide a fire hose at station in the emergency fire pump space. SOLAS 74 amendedII-2/21.
Condition: Unknown
Due 4 August 2001
Resolved 4 August 2001
Fire Fighting
Issued 11 June 2001 Resolved
Provide vent closure for emergency generator space. ICLL 1966 I/17.
Condition: Unknown
Due 4 August 2001
Resolved 4 August 2001
Engineering
Issued 11 June 2001 Resolved
Replace flame screens on vents for the ship's service generator crank cases. 33CFR160.125.
Condition: Unknown
Due 4 August 2001
Resolved 4 August 2001
Unknown
Issued 11 June 2001 Resolved
Remove oil from tunnel in engine room. 33CFR160.215.
Condition: Unknown
Due 4 August 2001
Resolved 4 August 2001
Navigation
Issued 26 June 2000 Resolved
ECHO DEPTH SOUNDER WAS OPERABLE. HOWEVER, THE RECORDER WAS INOPERABLE IN VIOLATION OF 33CFR164.35(i).
Condition: Unknown
Due 12 June 2001
Resolved 12 June 2001
Navigation
Issued 26 June 2000 Resolved
MANEUVERING INFORMATION FACT SHEET MISSING FROM BRIDGE IN VIOLATION OF 33CFR164.35(g). DOCUMENT ON ORDER AND EN ROUTE AT TIME OF INSPECTION.
Condition: Unknown
Due 12 June 2001
Resolved 12 June 2001

Ownership record