MAURY USCG vessel records
← All vessels

VALENTINE

VALENTINE is a 2008 tank ship. The Coast Guard has recorded 6 inspections since 2016, most recently in May 2023, along with 6 deficiencies and 3 operational controls.

Records from 2016 to 2023. Most recent: operational control imposed, 12 May 2023.

Built
2008
Last inspected
12 May 2023
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 12 May 2023
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 2 calendar years (2016–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9504023
1057258
Flag
PANAMA
Maury page id
psix-1057258

Documentation record

Tonnage as PSIX records it8417 - Convention (Subpart B), Gross Ton
4735 - Convention (Subpart B), Net Ton
14214 - Dead Weight, Ton
18569 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

6 inspections, each with its date, unit and type; 6 deficiencies with the resolution recorded against each; 3 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 6

12 May 2023 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7687068
5 April 2023 PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7661107
21 February 2023 In-Service Inspection · COC-CHEM & TVE Renew · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7639288
21 February 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7639721
16 February 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7637703
15 June 2016 Ballast Water Examination · COC-CHEM & TVE Renew · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5903171

Deficiency record · 6

02 - Structural Conditions › N/A - No Subsystem › Cargo tank vent system
Issued 21 February 2023 Resolved
The venting system shall be provided with devices to prevent the passage of flam into the cargo tanks. PSCO found heavily corroded and/or damaged flame screens in venting arrangements for cargo tanks 2P, 2s, 5P, 6P, and 8S. Ops restricted, see CoC. 74SOLAS(20)II-2/4.5.3.3 IBC 8.3.6
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 March 2023
Resolved 3 March 2023
Resolution: ClassNK report received and that replacement has completed.
12 - Dangerous Goods › N/A - No Subsystem › Other (tankers)
Issued 21 February 2023 Resolved
The showers and eyewash shall be operable in all ambient conditions. The water supply for the decontamination showers and eyewash stations was isolated rendering it inoperable despite the system being built to be in constant circulation. 74SOLAS(20)VII/Part B IBC 14.3.4
Action required: 10 - Deficiency Rectified
Due 2 March 2023
Resolved 2 March 2023
Resolution: The crew turned on the water for the eyewash and shower stations to show they worked. The crew left the water supply in the on position per the construction of the equipment.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 February 2023 Resolved
The function of fixed fire detection and fire alarm systems shall be periodically tested to the satisfaction of the administration by means of equipment producing hot air at the appropriate temperature. The PSCO identified that the vessel's crew members are testing heat detectors onboard with an incorrect testing apparatus per the vessel's safety management system. 74SOLAS(20)II-2/7.3.2
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 March 2023
Resolved 3 March 2023
Resolution: ClassNK Report received: The vessel had ordered one cordless heat detector testing kit and a fiberglass extension pole.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 21 February 2023 Resolved
Vessel had cargos, listed as incompatable, in 46 CFR Parto 150, in adjacent tanks.
Action required: 10 - Deficiency Rectified
Due 1 March 2023
Resolved 24 February 2023
Resolution: Cargos were internally transfered and rearranged in a manner which was in accordance with the cargo compatablity table of 46 CFR Part 150.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Valves
Issued 15 June 2016 Resolved
0725 - FIXED FIRE EXTINGUISHING INSTL - Firefighting systems & appliances shall be kept in good working order and readily available for immediate use. PSCO observed the remote operation for the hyper-mist fixed firefighting system to be inoperative. Master provided documentation of manned engine room and notification made to company and classification society. 74SOLAS(14)III/8.4.3
Action required: 705 - Other - as specified
Due 29 June 2016
Resolved 16 June 2016
Resolution: Received, reviewed and accepted proper documentation from Technician report, satisfying the requirement. Technician changed relay and fuse inside the control panel with power supply remaining steady and not blowing the internal fuse.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 15 June 2016 Resolved
0699 - OTHER - Illustrations & instructions in appropriate languages shall be posted in passenger cabins and displayed at muster stations and other passenger spaces to inform passengers of the method of donning lifejackets. PSCO observed that there were no lifejacket donning instructions posted at the muster station. Crew posted instructions prior to the conclusion of exam. 74SOLAS(14)II-2/10.5
Action required: 705 - Other - as specified
Due 15 June 2016
Resolved 15 June 2016
Resolution: Deficiency rectified on site by CG inspector.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.