The 7 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Share this recordDownload vessel cardDownload QRMaury, US Coast Guard vessel record for SAHBA, retrieved 18 September 2026. mauryrecords.com/v/psix-1057278.html
Documentation record
Tonnage as PSIX records it160782 - Convention (Subpart B), Gross Ton 109346 - Convention (Subpart B), Net Ton 160782 - Regulatory (Subpart C or D), Gross Ton 362661 - Displacement, Metric Ton 317563 - Dead Weight, Metric Ton 109346 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 7
18 October 2018Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6558258
29 December 2017COC-TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6323054
19 October 2016Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6016640
27 May 2014COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4866356
9 July 2012Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4356459
12 November 2010Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3889468
24 March 2010COC-TVE Renew
Administrative · Activities Europe · Activity 3701958
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 3 April 2010Resolved
various sections enclosed by A class divisions on the 'sunken deck' aft (emergency generator, paint locker, engin casing, etc) are not clearly indicated on the fire control plans.
Action required: 15 - Rectify deficiencies by next port
Due 3 April 2011
Resolved 12 November 2010
Resolution: MSU Morgan City PSCOs verified that the fire control plan is corrected and correctly marks all A class divisions.
Pollution Prevention/Response › Prevention Equipment › Standard Discharge Connection
Issued 3 April 2010Resolved
vessel's MARPOL standard discharge connection not readily available on board.
Action required: 15 - Rectify deficiencies by next port
Due 3 April 2011
Resolved 12 November 2010
Resolution: MSU Morgan City PSCOs verified that the standard discharge connection is now on board.
EEBDs, at least two as required by SOLAS, not found to be readily available within the accommodation spaces. Eight EEBDs were found in the foam contro room/fire lokcer, as indicated on the fire control plan.
Action required: 15 - Rectify deficiencies by next port
Due 3 April 2011
Resolved 12 November 2010
Resolution: MSU Morgan City PSCOs verified that two EEBDs in the fire locker, which is adjacent to accomodation spaces, meet the intent of the regulation.
The capacity for the tank for m ixing oil residues with fuel oil has been altered on the Supplement B on the IOPP Certificate, section 3.2.4. An original copy of the certificat with this alteration was no readily available on board.
Action required: 15 - Rectify deficiencies by next port
Due 3 April 2011
Resolved 12 November 2010
Resolution: MSU Morgan City PSCOs verified that the original IOPP and its supplement were available and corrected.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.