Records from 2019 to 2022. Most recent: inspection, 18 June 2022.
Inspection history · 5
18 June 2022
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7481588
13 June 2022
COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7476696
23 November 2019
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6865817
21 November 2019
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6859721
18 November 2019
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6857883
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 21 November 2019
Resolved
11124 - The steps of the embarkation ladder shall be made of hardwood free from knots or other irregularities. PSCO's observed atleast ten cracked rungs on the port side liferaft embarkation ladder. 74SOLAS(14)III/11.7; LSA Code 6.1.6.2.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 November 2019
Resolution: RECIEVED CLASS REPORT CLEARING DEFICIENCY
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 21 November 2019
Resolved
11119 - An immersion suit designed to be worn without a lifejacket shall be fitted with a light. PSCO observed ships immersion suits designed to be worn without a lifejacket were not fitted with lights. 74SOLAS(14)III/7.3; LSA 2.3.1.4
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 November 2019
Resolution: RECIEVED CLASS REPORT CLEARING DEFICIENCY
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 November 2019
Resolved
02108 - Electrical installations shall be such that electrical services essential for safety will be ensured under various emergency conditions. Electrical conduit near cargo hold no. 3 port side and motor controller for starboard side lifeboat davit both were observed to have exposed wiring due to corrosion. 74SOLAS(14)II-1/40.1.2
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 November 2019
Resolution: Temporarary repaired electrical conduit on main deck outvoard of no. 3 cargo hold.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 21 November 2019
Resolved
02105 - The equipment of the ship and it's equipment shall be maintained to conform with the provisions of the present regulations. PSCO observed hydraulic oil pooled in multiple locations around the steering gear. 74SOLAS(14)I/1.11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 November 2019
Resolution: Glands of steering gear tightened; Steering gear was functionally tested with satisfactory results.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 21 November 2019
Resolved
Stairways which penetrate more than a single deck shall be surrounded by at least "A-0" Class divisions and be protected by self-closing doors. PSCO observed upper deck stairway door does not secure when closed. 74SOLAS (04)II-2/9.2.3.4.1
Action required: 10 - Deficiency Rectified
Resolved 21 November 2019
Resolution: Self closing mecanism was changed and doodr handle was renewed. Door tested with satisfactory results.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 November 2019
Resolved
99101 - Cylinders must always be secured and when not in use they must be stowed in a rack in an upright position. Oxygen and acetylene bottles are being stored outside of their racks in their stowage locations and on the aft deck. 46CFR147.60(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 November 2019
Resolution: Crew returned oxygen and acetylene bottles to the proper stowage.