Inspection history · 15
20 January 2026
Deficiency Check · COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8291751
11 February 2025
Annual Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8078977
6 November 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8032150
5 February 2024
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7860526
26 January 2023
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7629295
13 December 2022
Drydock Exam · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7607932
28 February 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7403729
7 December 2020
Internal Structural Exam · DAPI Audit · Drydock Exam · COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7120820
7 May 2020
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6950321
26 February 2020
Internal Structural Exam · Administrative Inspection · Drydock Extension
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6916688
29 April 2019
Administrative Inspection · Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6690817
21 March 2018
DAPI Audit · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6376874
22 February 2018
Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6360222
16 August 2017
Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6241593
18 March 2016
DAPI Audit · COI Inspection · Hull Examination · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5837306
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 20 January 2026
Resolved
The design, materials, and construction of masts, posts, yards, on a sailing vessel must be suitable for the intended service;
Vessels faux hollow mast of slat construction has a slat on starboard side with a two foot section of rot from the bottom up with adjacent slat showing rot at base.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 February 2026
Resolution: Owner provided photo of repairs completed to base of mast. Cut and covered in fiberglass and epoxy.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 January 2026
Resolved
Flexible hose must be fabricated with an inner tube and a cover of synthetic rubber or other suitable material reinforced with wire braid;
Flexible hose through out fuel system had break down of synthetic rubber cover exposing inner material.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 February 2026
Resolved 20 February 2026
Resolution: Owner provided photos of new fuel lines installed on outboards.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 11 February 2025
Resolved
A vessel must comply with the applicable requirements for any radio installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80.
Radio is inoperable and needs to be replaced. Vessel restricted to operating within one thousand (1000) feet from shore until fixed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 February 2025
Resolved 18 February 2025
Resolution: Radio was replaced and reprogramed with MMSI
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 February 2025
Resolved
A vessel of more than 26 feet in length, but not more than 65 feet, must carry a minimum of one life buoy of not less than 24 inches in diameter.
Ring life buoy on board is worn and inoperable.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 February 2025
Resolved 18 February 2025
Resolution: Ring Bouy was replaced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 November 2024
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection. Conduct third party survey to evaluate condition of the rigging, rot in the wooden mast, and gaff boom. 46 CFR 177.100
Action required: 705 - Other - as specified
Resolved 5 December 2024
Resolution: Third party surveyor made all requisite repairs, see "Completed repairs 12.4.24"
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 February 2022
Resolved
A vessel not required to have a power driven fire pump must have at least three 2.5 gallon buckets with attached lanyard. One of the required fire buckets is missing. 46 CFR 181.610
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2022
Resolved 23 March 2022
Resolution: A third fire bucket was placed in service.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 February 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Cover missing for bow thruster wiring. 46 CFR 183.200(c)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 March 2022
Resolved 23 March 2022
Resolution: The cover was placed in service to cover the exposed wires.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 February 2022
Resolved
At least one life ring buoy must be fitted with a lifeline. Lifeline for life ring buoy is missing. 46 CFR 180.70(c)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2022
Resolved 23 March 2022
Resolution: A new lifeline was placed in service.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 February 2022
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 1 inch high indicating purpose of the valve and direction of operation. Fuel shut off valve is not labeled. 46 CFR 185.608
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 March 2022
Resolved 23 March 2022
Resolution: The fuel shutoff valves were labled for direction of flow.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 7 May 2020
Resolved
Show proper operation of high water alarm.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 May 2020
Resolution: High water alarm tested sat.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 7 May 2020
Resolved
Place in service a new marine grade bracket for 80: B/C portable fire extinguisher.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 May 2020
Resolution: A marine grade bracket was placed in service.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 May 2020
Resolved
Place in service 45 USCG approved Type I PFDs.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 May 2020
Resolution: New Type I PFDs were placed in service to meet requirement.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 7 May 2020
Resolved
Show proper operation of DSC capability on new VHF radio installation.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 May 2020
Resolution: DSC tested by FCC Tech, sat.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 7 May 2020
Resolved
Place in service one flashlight to meet emergency lighting requirement.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 May 2020
Resolution: Two flashlights were placed in service.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 May 2020
Resolved
Replace flexible hose for outboard engine and place in service emergency fuel shutoff valve and associated piping.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 May 2020
Resolution: Fuel lines were replaced to new and connected to fuel shutoff valves.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 April 2019
Resolved
Missing required 2a extinguisher.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2019
Resolved 17 May 2019
Resolution: Purchased new 2a extinguisher
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 April 2019
Resolved
Center bilge pump only works om manual.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2019
Resolved 17 May 2019
Resolution: Replaced float switch and conducted operational test.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 April 2019
Resolved
Lifefloat has improper batteries and submerged when tested
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2019
Resolved 17 May 2019
Resolution: Replaced batteris with batteries recomended by manufacturer
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 April 2019
Resolved
Port engine fuel line is missing the required hose clamps
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2019
Resolved 17 May 2019
Resolution: installed hose clamps on the fuel line.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 April 2019
Resolved
Missing 5 adult life jackets passenger cound reduced to 42
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 May 2019
Resolution: Replaced the missing life jackets
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 29 April 2019
Resolved
DSC radio not configure for operation. Required to be operation by next drydock.
Action required: 705 - Other - as specified
Resolved 19 May 2020
Communications › Alarms/Indicators › Bilge Alarm
Issued 16 August 2017
Resolved
Show proper operation of forward high water alarm.
Due 30 August 2017
Resolved 28 August 2017
Navigation › Piloting/Steering › Marine Charts
Issued 16 August 2017
Resolved
Update charts, light list & coast pilot.
Due 30 August 2017
Resolved 28 August 2017
Lifesaving › Lifebuoys › Serviceable
Issued 16 August 2017
Resolved
Renew grab lines on life ring.
Due 30 August 2017
Resolved 28 August 2017