MAURY USCG vessel records Sign in
← All vessels

ARIEL

ARIEL is a 2010 passenger vessel (inspected). The Coast Guard has recorded 13 inspections since 2010, most recently in June 2014, along with 15 deficiencies and 2 casualty investigations between 2011 and 2012.

Records from 2010 to 2014. Most recent: inspection, 10 June 2014.

Built
2010
Last inspected
10 June 2014
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

1057726
Flag
UNITED STATES
367457090, 367562550, 367652360 (licence lapsed)
Maury page id
psix-1057726

Inspections, by type

…with no type recorded7
Years with a record 4 calendar years (2010–2014)
The 13 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)34.0 ft × 10.3 ft × 5.2 ft
Registered tonnagegross 12 / net 9
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderFINELINE INDUSTRIES INC · MERCED, CA, UNITED STATES · built 2010
Hull materialFRP (Fiberglass)
PropulsionDiesel
Hull shapeShip
Hull configurationMonohull
Hailing portST PETE BEACH, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 9 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it9 - Simplified, Net Ton
12 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDH7862MMSI 367652360 · expired · compulsorily equipped · granted 7 January 2015, cancelled 15 March 2025
WDG6970MMSI 367562550 · expired · compulsorily equipped · granted 14 February 2013, cancelled 22 April 2023
WDF4904MMSI 367457090 · expired · compulsorily equipped · granted 12 June 2010, cancelled 15 August 2020 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 13

10 June 2014 Administrative Inspection · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4885290
27 July 2012 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4393143
25 July 2012 Type not recorded
No type recorded · Station (Small) Great Egg · USCG East District (CGD-E) · Activity 4391848
12 July 2012 Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4377298
29 June 2012 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4380632
28 May 2012 Type not recorded
No type recorded · Station (Small) Great Egg · USCG East District (CGD-E) · Activity 4324572
2 May 2012 Annual Inspection · DAPI Audit · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4298583
27 September 2011 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4155692
23 August 2011 DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4120723
20 August 2011 Damage Survey · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4121883
20 August 2011 Type not recorded
No type recorded · Station (Small) Great Egg · USCG East District (CGD-E) · Activity 4122468
20 August 2011 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4133088
8 March 2010 Initial Construction-Excluding Oversight
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4481717

Deficiency record · 15

Engineering › Diesel Engine (propulsion-direct drive) › Cylinder
Issued 12 July 2012 Resolved
High Pressure Pump seals found to be damaged causing fuel to enter oil system.
Action required: 705 - Other - as specified
Due 26 July 2012
Resolved 20 July 2012
Resolution: High pressure pump seals replaced and vessel was operationally tested in presence of Marine Inspectors all found to be satisfactory.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 23 August 2011 Resolved
No current COD was on hand for vessel, owner said he never got a renewal notice. 835 not to operate issued till valid COD onboard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 August 2011
Resolution: RCV copy of valid COD for vessel, cleared 835.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 23 August 2011 Resolved
No current fire safety equipment inspection completed on engine room fire extinguishing system, 835 not to carry passengers issued till fire safety cert completed. * (FE-241 system not CO2)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 August 2011
Resolution: system inspected, cleared 835.
Communications › Alarms/Indicators › High Water Alarm
Issued 23 August 2011 Resolved
FWD and AFT high water alarms not working or not installed 835 not to carry passengers issued till installed and operating.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 August 2011
Resolution: installed and tested both FWD and engine room high water alarms, SAT, cleared 835 item.
Operations/Management › Drills/Instruction › Not Conducted
Issued 23 August 2011 Resolved
Training logs not maintained 835 to complete in 7 days issued.
Action required: 705 - Other - as specified
Due 30 August 2011
Resolved 24 August 2011
Resolution: Trainiing logs being maintained, cleared 835
Engineering › Bilge Water Management System › Piping
Issued 23 August 2011 Resolved
Plastic elbows and plastic connections installed in bilge pump system, 835 to have all connections and elbows made metallic in bilge piping system in 7 days.
Action required: 705 - Other - as specified
Due 30 August 2011
Resolved 15 October 2012
Resolution: Bilge system in question was an extra installed on vessel. System has been removed completely from vessel as it is not required and the removal was more cost effective than replacing plastic hardware with metal.
Engineering › Bilge Water Management System › Piping
Issued 23 August 2011 Resolved
Install valve on bilge piping overboard in engine room, 835 to install in 7 days issued.
Action required: 705 - Other - as specified
Due 30 August 2011
Resolved 24 August 2011
Resolution: installed, SAT, cleared 835 item.
Engineering › Bilge Water Management System › Pump
Issued 23 August 2011 Resolved
New bilge pumps were installed this year, new pumps were not UL listed, 835 to prove or install proper UL listed bilge pumps in 7 days issued.
Action required: 705 - Other - as specified
Due 30 August 2011
Resolved 24 August 2011
Resolution: bilge pumps UL listed, cleared 835 item.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 23 August 2011 Resolved
Provide proof of pre-employment testing for all mariners in safety sensitive positions. Mariner's without such documenation may not be used in safety sensitive positions until proof of testing is produced.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 September 2011
Resolved 24 August 2011
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 23 August 2011 Resolved
Provide proof that all mariners in safety sensitive positions are enrolled in a random drug testing program. Mariner's without such documenation may not be used in safety sensitive positions until proof of enrollment is produced.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 September 2011
Resolved 24 August 2011
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 23 August 2011 Resolved
Provide proof a Management Information System Report was submitted to the Coast Guard by March 15, 2011 for the preceding year.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 September 2011
Resolved 29 September 2011
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 23 August 2011 Resolved
Provide proof that all covered employees and supervisors have received Employee Assistance Program training.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 September 2011
Resolved 29 September 2011
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 23 August 2011 Resolved
Post a valid company drug and alcohol policy statement
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 September 2011
Resolved 29 September 2011
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 23 August 2011 Resolved
Post Employee Assistance Program information including informational materials and community service hotline telephone numbers.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 September 2011
Resolved 29 September 2011
Personnel › Training › Personal Safety/Social Responsibilities
Issued 20 August 2011 Resolved
Conduct drill and annual inspection with master and crew prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 August 2011
Resolution: drills conducted SAT

Casualty record · 2

20 August 2011Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4133088
29 June 2012Routine · role: Involved in a Marine Casualty · activity 4380632
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.