← All vessels
NAVIGATOR VESTA
NAVIGATOR VESTA is a 2009 tank ship. The Coast Guard has recorded 13 inspections since 2020, most recently in April 2026, along with 3 deficiencies and 1 operational control.
Records from 2020 to 2026. Most recent: inspection, 27 April 2026.
- Built
- 2009
- Last inspected
- 27 April 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 3 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9402574 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
D5CI5
1057826
Flag
LIBERIA
—
Maury page id
psix-1057826
Inspections, by type
…with no type recorded3
Years with a record
7 calendar years (2020–2026)
The 13 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it13879 - Convention (Subpart B), Gross Ton
4399 - Convention (Subpart B), Net Ton
26376 - Displacement, Ton
18919 - Dead Weight, Ton
4399 - Convention (Subpart B), Net Ton
26376 - Displacement, Ton
18919 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 13
27 April 2026
Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8356798
30 March 2026
Administrative Inspection · COC-GAS Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8329606
22 May 2025
COC-GAS Annual
Type not classified · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8139811
20 March 2024
COC-GAS Renew · Deficiency Check · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7882068
10 March 2023
PSC B · COC-GAS Annual
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7648770
15 March 2022
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7412158
13 March 2022
PSC B · Ballast Water Examination · COC-GAS Renew · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7410939
9 June 2021
COC-GAS Annual · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7218560
27 May 2020
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6961662
27 May 2020
COE-Offshore
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7014242
1 March 2020
COC-GAS Renew · PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6915813
1 March 2020
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6918308
21 February 2020
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6912931
Deficiency record · 3
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 30 March 2026
Resolved
74 SOLAS(20)11-145.11
In tankers, electrical equipment, cables and wiring shall not be installed in hazardous locations unless it conforms with standards not inferior to those acceptable to the organization. PSCO observed 2 cracked lights in the compressor room.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 20 March 2024
Resolved
On ships carrying flammable or toxic products or both, a water spray system for cooling, fire prevention, and crew protection should be installed to cover:
Cargo liquid and vapour discharge and loading manifolds and the are of their control valves.
The system should be capable of covering all areas mentioned with a uniformly distributed water spray of at least 10 l/m2 for horizontal projected surfaces and 4 l/m2 per minute for vertical surfaces.
Deck water spray on port & starboard manifolds and forecastle is not providing adequate coverage.
74SOLAS (20) VII/13.1
IGC (93) 11.3.1 & .2
17AC
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 20 March 2024
Resolved
Oil fuel pipes, which, if damaged, would allow oil to escape from a storage, settling, or daily service tank having a capacity of 500L and above...shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside the space concerned in the event of a fire.
PSCO observed quick closing valve for the emergency diesel generator inoperable.
74SOLAS (2004) II-2/4.2.2.3.4
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.