Documentation record
Registered dimensions (L × B × D)40.0 ft × 12.0 ft × 3.5 ft
Registered tonnagegross 5 / net 5
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSIGHTSEER MARINE LLC · HUDSON, FL, UNITED STATES · built 2010
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTwin Hull
Hailing portSWANSBORO, NC
Endorsements, as the file codes themcw_un
DocumentationValid · issued 19 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it5 - Simplified, Gross Ton
5 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 18
6 May 2026
Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8368693
5 February 2026
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8306785
24 February 2025
COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8083788
12 February 2024
Drydock Exam · Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7864141
12 June 2023
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7712756
1 February 2023
Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7637578
1 December 2022
In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7602667
1 June 2022
Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7465160
18 March 2022
Hull Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7412385
7 June 2021
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7218810
28 April 2020
COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6942351
24 March 2020
Hull Examination · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6931330
10 July 2019
Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6745106
17 July 2018
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6467134
8 March 2018
Drydock Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6363502
30 October 2017
Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6297337
5 June 2017
Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6162275
22 March 2016
Drydock Exam · Hull Examination · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5837967
05 - Radio Communications › N/A - No Subsystem › Performance standards for radio equipment
Issued 4 March 2025
Resolved
DSC acknowledgment of DSC distress and safety calls must be made by designated coast stations and such acknowledgment must be in accordance with procedures contained in ITU-R M.541-9 (incorporated by reference, see § 80.7).
VHF radio installed on vessel was not properly acknowledging DSC test call. Make repairs and show proof of proper operation to attending MI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2025
Resolved 20 March 2025
Resolution: Owner replaced antenna. DSC tested, all SAT.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 June 2023
Resolved
At each subsequent inspection for certification, the owner or managing operator must be have the vessel ready for inspection of its fire protection equipment, including the following: (1) Inspection of each portable fire extinguisher to check for excessive corrosion and general condition. 02 Portable fire extinguishers were condemned due to excessive corrosion. Renew in kind.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2023
Resolution: 02 Portable fire extinguishers renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 12 June 2023
Resolved
A vessel on a lakes, bays, and sounds must carry: (1) Three hand red flare distress and three hand orange smoke distress signals. Vessel missing three hand held smoke distress signals.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2023
Resolution: Three day/night flares installed on the vessel.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 12 June 2023
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Port running light is inoperable. Prove proper operation to the attending Marine Inspector.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2023
Resolution: Port running light is now operational.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 12 June 2023
Resolved
A vessel must carry either a first-aid kit that meets
the requirements in 46 CFR 199.175(b)(10) or a kit
with equivalent contents and instructions. Aspirin is
expired. Renew in kind.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2023
Resolved 12 June 2023
Resolution: Aspirin was renewed and added to the first aid kit.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 December 2022
Resolved
Except as provided in paragraph (b) of this section, each vessel must have a stability letter issued by the Coast Guard before the vessel is placed into service. this letter sets forth conditions of operation. Vessel owner installed two new outboard engines resulting in a weight change. Submit aggregate weight change to the Marine Safety Center for lightship change determination.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 December 2022
Resolved 27 December 2022
Resolution: Owner submitted outboard engine weight information to the Marine Safety Center. MSC determination uploaded in MISLE.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 June 2021
Resolved
02 Child life jackets found un-servicable. Renew and properly mark.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2021
Resolved 21 June 2021
Resolution: 02 Child life jackets provided and properly marked.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 7 June 2021
Resolved
Crew training shall be logged or otherwise documented for the review by the Coast Guard.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 7 June 2021
Resolved 7 June 2021
Resolution: Conducted man overboard drill and fire drill during the annual inspection. Drills were properly logged.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 June 2021
Resolved
Renew waterlight battery for life ring buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2021
Resolved 21 June 2021
Resolution: water light battery renewed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 June 2021
Resolved
Re-attach bonding wires for fuel tanks.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 7 June 2021
Resolved 7 June 2021
Resolution: Bonding wire is now attached on fuel tanks.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 7 June 2021
Resolved
First aid kit expired aspirin
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2021
Resolved 21 June 2021
Resolution: Provided aspirin to the first aid kit
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 7 June 2021
Resolved
Provide portable watertight container for distress and clearly mark (0.5 inches high "DISTRESS SIGNALS"
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2021
Resolved 21 June 2021
Resolution: Watertight container is now onboard the vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 7 June 2021
Resolved
Provide proper label for port side fuel cut-out valve.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2021
Resolved 21 June 2021
Resolution: Valve was properly labeled.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 17 July 2018
Resolved
No proof of drug enrollment and drug testing enrollment of consortium.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 August 2018
Resolved 17 July 2018
Resolution: Received, reviewed, and accepted documentation for enrollment.
02 - Structural Conditions › N/A - No Subsystem › Cargo tank vent system
Issued 17 July 2018
Resolved
MSD vent screen replace is damaged.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 16 August 2018
Resolved 18 October 2018
Resolution: New vent installed, all SAT.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 17 July 2018
Resolved
Did not conduct MOB due to weather. Conduct man overboard drills and underway sea trials.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 July 2018
Resolved 18 October 2018
Resolution: All Sat. Discussed procedures for drills due to weather.
Construction/Loadline › Hull › Bottom Plating
Issued 8 March 2018
Resolved
Plywood to frame bolts loose.
Action required: 705 - Other - as specified
Due 8 March 2018
Resolved 20 March 2018
Resolution: Checked fasteners in question for tightness SAT.
Construction/Loadline › Structures › Superstructure
Issued 8 March 2018
Resolved
Canopy rail cracked over operators station.
Action required: 705 - Other - as specified
Due 8 March 2018
Resolved 8 April 2018
Resolution: Welded canopy cracks
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 22 March 2016
Resolved
Update navigation publications for area of operation (Tide/Currents, Light List, Coast Pilots)
Due 22 April 2016
Resolved 9 May 2016
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 March 2016
Resolved
Replace expired meds in First Aid kit
Due 22 April 2016
Resolved 9 May 2016
Engineering › Gasoline Engine (propulsion) › Ignition Wire (4 cycle)
Issued 22 March 2016
Resolved
Repair port outboard engine relay
Due 22 April 2016
Resolved 9 May 2016
Operations/Management › Drills/Instruction › Not Conducted
Issued 22 March 2016
Resolved
Conduct drills and operational test of propulsion and steering
Due 22 April 2016
Resolved 9 May 2016