MAURY USCG vessel records
← All vessels

VANTAGE REEF

VANTAGE REEF is a 2010 freight ship. The Coast Guard has recorded 3 inspections since 2016, most recently in August 2022, along with 7 deficiencies.

Records from 2016 to 2022. Most recent: inspection, 30 August 2022.

Built
2010
Last inspected
30 August 2022
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9422495
1058111
Flag
LIBERIA
Maury page id
psix-1058111

Inspections, by type

Years with a record 2 calendar years (2016–2022)
The 3 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it18493 - Convention (Subpart B), Gross Ton
10335 - Convention (Subpart B), Net Ton
29262 - Dead Weight, Metric Ton
36868 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 3

30 August 2022 PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7537400
31 October 2016 Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6032340
26 September 2016 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6002443

Deficiency record · 7

Engineering › Fuel Oil Storage/Transfer System › Pump
Issued 26 September 2016 Resolved
MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. PSCO OBSERVED APPROXIMATELY 2 INCHES OF FUEL OIL IN BILGE UNDER PURIFIER. SOLAS 74(09 CONS) CHII-2 REG 4.1.1.
Due 26 September 2016
Resolved 26 September 2016
Resolution: CLEARED ON THE SPOT.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 26 September 2016 Resolved
THE ARRANGEMENT FOR THE STORAGE OF FUEL OIL SHALL BE TO ENSURE THE SAFETY OF SHIP AND CREW. PSCO OBSERVED FUEL OIL BEING STORED AROUND MACHINERY IN THE ENGINE ROOM. SOLAS 74 (09 CONS) CH II-2 REG 4.2.2
Due 26 September 2016
Resolved 26 September 2016
Resolution: CLEARED ON THE SPOT.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 26 September 2016 Resolved
DOORS FITTED IN BOUNDARY BULKHEADS OF MACHINERY SPACES OF CATEGORY A SHALL BE REASONABLY GASTIGHT AND SELF-CLOSING. PSCO DISCOVERED 07 SELF- CLOSING DOORS UNABLE TO CLOSE. SOLAS 74 (09 CONS) CH. II-2 REG 9.4.2.8
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 31 October 2016
Resolved 31 October 2016
Resolution: SEC HOU-GAL PSC received a requisition report from master satisfying the requirement. PSCO boarded and ensured fire doors all operate according to SOLAS 74 (09 CONS) CH.II-2 REG 9.4.2.8.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Valves
Issued 26 September 2016 Resolved
FIRE-EXTINGUISHING APPLIANCES SHALL BE READILY AVAILABLE. PSCO OBSERVED THE ISOLATION VALVE FROM THE TANK TO THE WATER MIST WAS MANUALLY SECURED. SOLAS 74 (09CONS) CH. II-2 REG 10.1.2
Due 26 September 2016
Resolved 26 September 2016
Resolution: CORRECTED ON THE SPOT.
Lifesaving › Rescue Boat Equipment › Electric Torch
Issued 26 September 2016 Resolved
ALL LIFE-SAVING APPLIANCES SHALL BE IN WORKING ORDER AND READY FOR IMMEDIATE USE. [name withheld] MISSING SEARCH LIGHT. SOLAS 74 (09CONS) CH. III REG 20.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 31 October 2016
Resolved 31 October 2016
Resolution: SEC HOU-GAL PSC received a requisition report from vsl master satisfying the requirement. PSCO boarded vsl and verified acquisition of new Halogen spotlight.
Lifesaving › Inflatable Liferafts › Approval
Issued 26 September 2016 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 26 September 2016
Resolved 26 September 2016
Resolution: CLEARED ON THE SPOT.
Operations/Management › Vessel Safety Management › External Certification/Verification/Control
Issued 26 September 2016 Resolved
THE COMPANY AND THE SHIP SHALL COMPLY WITH THE REQUIREMENTS OF THE ISM CODE. RECOMMEND ISM SAFETY AUDIT BE CONDUCTED TO DETERMINE IF REQUIRED FIRE-FIGHTING AND LIFE-SAVING IS BEING CONDUCTED IN ACCORDANCE WITH SMS. SOLAS 74 (09CONS) CH. IX REG 3.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 September 2016
Resolved 26 September 2016

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.