MAURY USCG vessel records
← All vessels

DONG-A METIS

DONG-A METIS is a 2010 freight ship. The Coast Guard has recorded 17 inspections since 2017, most recently in May 2026, along with 11 deficiencies.

Records from 2017 to 2026. Most recent: inspection, 15 May 2026.

Built
2010
Last inspected
15 May 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 15 May 2026
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2017–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9419747
1058225
Flag
PANAMA
Maury page id
psix-1058225

Documentation record

Tonnage as PSIX records it60396 - Convention (Subpart B), Gross Ton
27647 - Convention (Subpart B), Net Ton
22582 - Dead Weight, Metric Ton
42759 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 17

15 May 2026 PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8373661
5 August 2024 PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7971200
16 February 2023 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7638001
4 January 2023 PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7614896
26 December 2022 Administrative Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7613112
11 November 2022 Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7593022
11 November 2022 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7593085
10 November 2022 PSC B · Ballast Water Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7589139
7 April 2022 PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7418981
19 January 2021 Administrative Inspection · PSC B
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7121975
16 December 2020 In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7113004
16 December 2020 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7140067
29 July 2020 Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7021252
10 June 2019 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6700759
13 December 2018 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6597328
9 January 2018 Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6334750
17 November 2017 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6305796

Deficiency record · 11

11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 4 January 2023 Resolved
11135 - MAINTENANCE OF LIFESAVING APPLIANCES - MAINTENANCE, TESTING AND INSPECTIONS OF LIFE-SAVING APPLICANCES SHALL BE CARRIED OUT BASED ON THE GUIDELINES DEVELOPED BY THE ORGANIZATION AND IN A MANNER HAVING DUE REGARD TO ENSURING RELIABILITY OF SUCH APPLICANCES. PSCO OBSERVED THE BRACKET FOR THE PORT FREE FALL LIFEBUOY TO BE HEAVILY CORRODED WHERE PIN PASSES THROUGH - 74 SOLAS (20) III / 20.3.1 - 16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 January 2023
Resolved 8 February 2023
Resolution: RECEIVED CLASS REPORT ATTESTING TO REPAIRS
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 4 January 2023 Resolved
15106 - SHIPBOARD OPERATIONS - THE COMPANY AND THE SHIP SHALL COMPLY WITH THE REQUIREMENTS OF THE INTERNATIONAL SAFETY MANAGEMENT CODE. THE COMPANY SHOULD ESTABLISH PROCEDURES, PLANS AND INSTRUCTIONS, INCLUDING CHECKLISTS AS APPROPRIATE, FOR KEY SHIPBOARD OPERATIONS CONCERNING THE SAFETY OF PERSONNEL, SHIP AND PROTECTION OF THE ENVIRONMENT.PSCO OBSERVED INSUFFICIENT GMDSS PROCEDURE WHEN IN PORT RESULTING IN A LACK OF LOG BOOK ENTRIES. - 74 SOLAS (20) IX/3.1, ISM CODE PART A/7 - 50ac
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 February 2023
Resolved 8 February 2023
Resolution: RECEIVED CLASS REPORT ATTESTING TO REPAIRS
05 - Radio Communications › N/A - No Subsystem › Radio log (diary)
Issued 4 January 2023 Resolved
05115 - RADIO LOG - ALL SHIPS ENGAGED ON INTERNATIONAL VOYAGES SHALL KEEP ON BOARD A RECORD OF NAVIGATIONAL ACTIVITIES AND INCIDENTS WHICH ARE OF IMPORTANCE TO SAFETY OF NAVIGATION AND WHICH MUST CONTAIN SUFFICIENT DETAIL TO RESTORE A COMPLETE RECORD OF THE VOYAGE. PSCO OBSERVED MULTIPLE MISSING ENTRIES IN THE RADIO LOG BOOK FOR DATES WHEN THE VESSEL WAS IN PORT - 74 SOLAS (20) V/28.1 - 50ac
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 February 2023
Resolved 8 February 2023
Resolution: RECEIVED CLASS REPORT ATTESTING TO REPAIRS
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 November 2022 Resolved
A main source of electrical power of sufficient capacity to supply all those services mentioned in regulation 40.1.1 shall be provided. This main source of electrical power shall consist of at least two generating sets. Vessel experienced two blackouts caused by generator over speeds while utilizing bow thruster. - SOLAS (cons) II-1/41.1.1
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 November 2022
Resolution: Vessel submitted class report and electrical technician report showing resolution of issues, including repair of malfunctioning main breaker and adjustment of generator governors.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 10 November 2022 Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. The ignitability of combustible materials shall be restricted... found 03 lube oil soaked rags under the steering gear. 74SOLAS(14) II-2/4.1.3.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 November 2022
Resolved 10 November 2022
Resolution: Corrected on the spot
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 10 November 2022 Resolved
The company should establish procedures to ensure the ship is maintained in conformity with the provisions of the relevant rules. Ship found with 08 fire extinguishers overdue for service. SMS does not address deck arrangement that temporarily blocks access for service and the service of those extinguishers when the deck arrangement is unblocked. 74SOLAS(14) IX/3.2 ISM clause 10.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 December 2022
Resolved 26 December 2022
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 7 April 2022 Resolved
07126 - Oil accumulation in engine room - Means shall be provided to control leaks of flammable liquids. PSCO found several areas where the accumulation of oil and leaks were present, including: #2 and #6 FO Pump on Main Engine, #5 and #6 Main Engine Drain Lines, HFO Transfer Pump and Piping , #2 GE Lube Oil Cooler, #1, #2 and #3 GE catch drain, and sludge pump transfer piping. SOLAS 74 (09) II-2, 4.1.1 – 17ac
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 April 2022
Resolution: Received, reviewed and accepted class report from [name withheld] stating the deficiency was rectified. See class report.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 7 April 2022 Resolved
04103 -Emergency, lighting, batteries and switches - Muster and embarkation stations shall be adequately illuminated by lighting supplied from the emergency source of electrical power…alleyways, stairways and exits giving access to the muster and embarkation stations shall be lighted. PSCO observed approximately 17 emergency light bulbs not illuminated. SOLAS 74 (20) III/11.4 & 11.5 – 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 7 April 2022
Resolution: Deficiency Corrected on the Spot
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 April 2022 Resolved
09209 - Electrical - Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards will be ensured. PSCO observed 02 electrical panels open inside the engine control room on the backside. SOLAS 74 (09) II-1/40.1.3 – 10c
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 7 April 2022
Resolution: Deficiency corrected on the spot
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 December 2020 Resolved
Sufficient power for going astern shall be provided to secure proper control of the ship in all normal circumstances. PSCO was notified that starting air for vessel was empty due to set telegraph handle between stop and dead slow being in wrong astern position, resulting in a loss of propulsion while entering COTP Zone. Vessel also experienced an electrical failure to the bow thruster while mooring in Benicia, Ca. 74SOLAS(04)II-I/28.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 December 2020
Resolution: Korean Register attended vessel. Found improper positioning of Control Air Valve handle. Verified propulsion and required crew conduct training
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 17 November 2017 Resolved
The fixed fire detection system shall initiate audible and visual alarms. Indicator panel on port side next to generator No.1 found inoperable.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 January 2018
Resolution: MSU Savannah recieved documentation from vessel provideing evidence the necessary reaparis have been conducted.

Ownership record