DESERT RHAPSODY
DESERT RHAPSODY is a 2007 freight ship. The Coast Guard has recorded 15 inspections since 2011, most recently in February 2023, along with 9 deficiencies and 2 operational controls.
Records from 2011 to 2023. Most recent: inspection, 10 February 2023.
- Built
- 2007
- Last inspected
- 10 February 2023
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 9 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9321005 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7II2
1058244
Flag
MARSHALL ISLANDS
—
Maury page id
psix-1058244
Inspections, by type
…with no type recorded4
Years with a record
7 calendar years (2011–2023)
The 15 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it31091 - Convention (Subpart B), Gross Ton
17993 - Convention (Subpart B), Net Ton
54070 - Dead Weight, Metric Ton
64320 - Displacement, Metric Ton
17993 - Convention (Subpart B), Net Ton
54070 - Dead Weight, Metric Ton
64320 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 15
10 February 2023
PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7631049
8 February 2023
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7634208
1 February 2023
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7630484
31 July 2021
Deficiency Check · Administrative Inspection · PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7273265
27 July 2021
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7269839
27 July 2021
COE-Offshore
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7269846
16 April 2019
COE-Administrative · Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6659077
7 September 2018
COE-Dockside
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6528907
19 November 2017
ISPS II Exam · COE-Offshore · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6307196
18 February 2017
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6090788
17 February 2017
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6090102
20 January 2017
COE-Dockside · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6070568
31 July 2016
PII Safety Exam · COE-Offshore · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5950962
23 December 2011
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4209929
17 December 2011
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4209951
Deficiency record · 9
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boat inventory
Issued 10 February 2023
Resolved
A food ration as described in paragraph 4.1.5.1.18 totalling not less than 10,000 kW for each person the lifeboat is permitted to accomodate; these rations shall be kept in airtight packaging and be stowed in a watertight container.
Port side lifeboat had 01 rations not in airtight packaging.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 31 July 2021
Resolved
13101 - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. PSCO observed cooling water leaking from the No.4 cylinder on the main engine.
74SOLAS(20)I/II(a)
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 31 July 2021
Resolved
07126- Means shall be provided to control leaks of flammable liquids. PSCO observed fuel oil leaking from the main engine fuel oil drain line with oil soaked lagging around the pipeline. Additionally, the PSCO observed fuel oil leaking from valve connections to the HFO service tank. In the purifier room the PSCO observed a sink filled with oil.
74SOLAS(20)II-2/4.1.1
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 31 July 2021
Resolved
09209- Cables and wiring shall be installed and supported to avoid chafing and other damage. PSCO observed deterioration on numerous electrical enclosures on deck preventing them from closing. Additionally, portions of the enclosures were missing. The vessel's crew covered all enclosures with tarps to prevent water ingress.
74SOLAS(04)II-1/45.5.5
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil/water interface detector
Issued 31 July 2021
Resolved
14109- For test specifications related to 15 PPM bilge separators tests should be performed using three grades of fluids. PSCO observed the engineers testing oil content meter with coffee which is not an approved fluid.
MARPOL I/14.7
MEPC.107(49)1.2.4
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 31 July 2016
Resolved
0715-Detection-A fixed fire detection and fire alarm system shall be installed in periodically unattended machinery spaces and shall initiate audible and visual alarms in sufficient places to ensure the alarms are heard and observed. The installed fire detection and alarm system for the engine room is not functioning due to an electrical problem identified within the PCB. 17ac
Lifesaving › Lifeboat Equipment › Food Ration
Issued 17 December 2011
Resolved
LSA 4.4.8.12 Food rations shall be kept in airtight packaging and be stowed in a watertight container. 6 food rations onboard the lifeboat are no longer airtight.
Communications › Radio Communications › VHF Radiotelephone
Issued 17 December 2011
Resolved
Solas (cons 2009) CH III Reg 6.2.1.1. Equipment for which the source of energy is intended to be user-replaceable should be provided with a dedicated primary battery for use in the event of a distress situation. The vessel is missing one dedicated two-way portable life-saving radio with seal to indicate it has not been used.
Navigation › Piloting/Steering › Maneuvering Information Fact Sheet
Issued 17 December 2011
Resolved
Each vessel must have maneuvering information displayed on a fact sheet in the wheelhouse. The vessel does not have one.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.