BLUE PRINCE is a 2009 tank ship. The Coast Guard has recorded 13 inspections since 2016, most recently in February 2026, along with 7 deficiencies and 3 operational controls.
Records from 2016 to 2026. Most recent: operational control imposed, 12 February 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it60237 - Convention (Subpart B), Gross Ton 33762 - Convention (Subpart B), Net Ton 127354 - Displacement, Ton 109010 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 13
12 February 2026COC-TVE Renew · Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8306002
18 February 2025Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8080956
5 January 2025PSC B · Administrative Inspection · COC-TVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8057281
5 July 2024Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7950837
2 November 2023COC-TVE Renew · PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7815693
20 August 2021COC-TVE Renew · PSC B
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7288523
18 August 2021COE-Administrative
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7290049
12 November 2018ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6574003
5 November 2018Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6574513
23 January 2018ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6335802
21 August 2016Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5978469
19 August 2016Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5977339
29 March 2016COC-TVE Annual · Ballast Water Examination · ISPS II Exam
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 February 2026Resolved
PSCO observed approximately 10 light fixtures in the cargo pump room with a variety of issues including comprimized glands, improper repair of glands, missing grounding wires, and exposed wiring. In addition, a telephone electrical housing was missing 02 screws; comprimising casing.
Condition: Improper/Lack of Maintenance
Action required: 25 - Ship denied entry
Resolved 14 February 2026
Resolution: Fixed lights and phone box
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 February 2026Resolved
Vessel could not produce foam analysis report for loe-expansion foam.
Condition: Placed in Improper Service
Action required: 25 - Ship denied entry
Resolved 14 February 2026
Resolution: Ships crew found the foam analysis report
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 February 2026Resolved
PSCO observed that the Clean in Place (CIP) system has been modified to use flexible hoses in lieu of original hard pipes to operate.
Action required: 25 - Ship denied entry
Resolved 14 February 2026
Resolution: Flexible hoses were removed
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 November 2023Resolved
IN TNAKERS, ELECTRICAL EQUIPMENT, CABLES AND WIRING SHALL NOT BE INSTALLED IN HAZARDOUS LOCATIONS UNLESS IT CONFORMS WITH STANDARDS NOT INFERIOR TO THOSE ACCEPTABLE TO THE ORGANIZATION. PSCO OBSERVED A TOTAL OF 04 LIGHT FIXTURES IN PUMP ROOM THAT DID NOT CONFORM WITH STANDARDS. 03 LIGHTS WERE MISSING GROUNDING WIRES. 01 LIGHT WAS NOT PROPERLY SEALED. CREW CORRECTED ON SPOT.
74 SOLAS (20) II-1/45.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 November 2023
Resolved 2 November 2023
Resolution: CREW ADDED GROUNDING WIRES TO THE CORRECT POSITIONS AND PROPERLY SEALED A LIGHT.
02 - Structural Conditions › N/A - No Subsystem › Safe access to tanker bows
Issued 2 November 2023Resolved
EVERY TANKER SHALL BE PROVIDED WITH THE MEANS TO ENABLE THE CREW TO GAIN SAFE ACCESS TO THE BOW, EVEN IN SEVERE WEATHER CONDITIONS. PSCO OBSERVED MULTIPLE STORM SHELTERS ON DECK WERE FILLED WITH DECK EQUIPMENT. CREW CORRECTED ON SPOT.
74 SOLAS (20) II-1/3-3.2
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 2 November 2023
Resolved 2 November 2023
Resolution: CREW REMOVED EQUIPMENT AND PROPERLY STOWED.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 August 2021Resolved
In tankers, electrical equipment and wiring shall not be installed in hazardous locations unless it conforms with standards acceptable to the organization. Cover on overhead intrinsically safe light not sealed properly. Light not operating in accordance with manufacturers specification.
Action required: 10 - Deficiency Rectified
Resolved 20 August 2021
Resolution: Vessel replaced light with ships spares. Repair witnessed by attending Flag rep.
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 23 January 2018Resolved
0599-Other(working spaces) - Suitable portable or fixed gas sampling lines shall be provided in double hull and double bottom spaces to measure oxygen and flammable vapour concentrations. When testing for flow fault on sampling point 04, fixed sampling unit showed a flow fault alarm on sampling point 12 indicating sampling lines were not routed properly. 74 SOLAS(14 Cons.) II-2/5.7.2
Action required: 705 - Other - as specified
Due 23 January 2018
Resolved 23 January 2018
Resolution: Vessel crew was able to properly aline sample lines and produce a proper test for fault alarms.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.