Records from 2016 to 2026. Most recent: inspection, 4 March 2026.
Inspection history · 6
4 March 2026
Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8320063
15 November 2025
PSC B
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8262780
1 February 2024
PSC B · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7835852
15 August 2021
PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7269540
22 March 2018
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6372082
28 January 2016
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5802106
02 - Structural Conditions › N/A - No Subsystem › Enhanced survey programme (ESP)
Issued 15 November 2025
Resolved
02119 - THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. PSCO OBSERVED WATER LEAKING IN A SUBSTANTIAL AMOUNT FROM THE #1 BALLAST PUMP. SOLAS 74(20) I/11(a)-15ac
Action required: 15 - Rectify deficiencies by next port
Resolved 4 March 2026
Resolution: DOCUMENTATION PROVIDED ATTESTING TO RECTIFICATION OF DEFICIENCY
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 August 2021
Resolved
THE MACHINERY, BOILERS AND OTHER PRESSURE VESSELS, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED. PSCO OBSERVED STEERING GEAR DRIFT OF APPROXIMATELY 1 DEGREE EVERY 25 SECONDS ON BOTH STEERING PUMPS IN REMOTE AND LOCAL CONTROL. 74 SOLAS (14) II-1/26.1-17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 August 2021
Resolved 16 August 2021
Resolution: Received report attesting to proper operation of vessel's steering gear system.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 15 August 2021
Resolved
THE RING AND LETTERS SHALL BE PAINTED IN WHITE OR YELLOW ON A DARK BACKGROUND OR IN BLACK ON A LIGHT BACKGROUND. PSCO OBSERVED THE BOTTOM HALF OF THE RING OF THE LOADLINE MARK AND THE WINTER LOAD LINE NOT PAINTED IN CONTRASTING COLOR ON BOTH SIDES OF THE VESSEL. ICLL 88 Reg 8
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 September 2021
Resolved 5 February 2024
Resolution: PSCO observed a proper loadline IAW certificate.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 22 March 2018
Resolved
9900-Other (not clearly hazardous)-Doors required to be self-closing shall not be fitted with hold-back devices. PSCO observed hold backs on both class-A self-closing doors in the galley. SOLAS 74 (a) 2009 Cons. II-2/9.4.2.2 16a
Action required: 705 - Other - as specified
Due 5 April 2018
Resolved 28 March 2018
Resolution: PSC received class report from RINA satisfying the requirements.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 22 March 2018
Resolved
2420-change over procedures-Ships shall carry a written procedure showing how the fuel oil changeover is to be done allowing sufficient time for the feul oil service system to be fully flushed. PSCO observed no HFO/MGO transfer procedures. MARPOL Annex VI/14.6 c
Action required: 705 - Other - as specified
Due 22 March 2018
Resolved 28 March 2018
Resolution: PSC received approved HSFO/MGO changeover procedures.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 28 January 2016
Resolved
0611-The lifeboats shall be provided a food ration of not less than 10,000 kJ for each person. PSCO observed that the packaging for 9 of the 25 food provisions were not airtight. Lifeboat is 25person Max. 74SOLASam III/34 LSA Code 4.4.8.12
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 January 2016
Resolved 2 February 2016