← All vessels
GRAND VEGA
GRAND VEGA is a 2009 freight ship. The Coast Guard has recorded 14 inspections since 2011, most recently in February 2026, along with 9 deficiencies and 2 operational controls, 2 with no removal date recorded.
Records from 2011 to 2026. Most recent: inspection, 14 February 2026.
- Built
- 2009
- Last inspected
- 14 February 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 9 recorded · 0 without a recorded resolution
- Controls
- 2 with no removal date recorded
Identity
9355252 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3FWB5
1060307
Flag
PANAMA
—
Maury page id
psix-1060307
Inspections, by type
…with no type recorded1
Years with a record
12 calendar years (2011–2026)
The 14 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it59217 - Convention (Subpart B), Gross Ton
17766 - Convention (Subpart B), Net Ton
18049 - Dead Weight, Ton
34670 - Displacement, Ton
17766 - Convention (Subpart B), Net Ton
18049 - Dead Weight, Ton
34670 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 14
14 February 2026
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8310612
2 April 2025
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8103730
3 October 2022
Ballast Water Examination · PSC B
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7570867
30 March 2022
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7421638
29 January 2021
PSC A
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7128113
7 October 2020
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7073139
30 September 2020
PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7066797
6 February 2019
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6616355
22 January 2018
PII Safety Exam · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6341245
19 August 2016
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5973487
20 August 2015
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5222005
10 March 2014
PII Safety Exam · ISPS II Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4813000
17 February 2012
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4246606
25 July 2011
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4093415
Deficiency record · 9
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 2 April 2025
Resolved
Fire fighting systems and appliances shall be kept in good working order and readily available for immediate use. Vessel reported emergency fire pump is inoperable.
74 SOLAS (20 Cons) II-2/14.2.1.2
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 30 March 2022
Resolved
All ships of 3,000 gross tonnage and upwards shall have a 3 GHz radar or, where considered appropriate by the Administration, a second 9 GHz radar, or other means, to determine and display the range and bearing of other surface craft, obstructions, buoys, shorelines and navigational marks to assist in navigation and in collision avoidance, which are functionally independent.
Vessel does not have a functional 3 GHz radar.
74 SOLAS 2020 con. V/19.2.7.1
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 October 2020
Resolved
Participating ships must make report to the U.S. Coast Guard upon entering the area covered by a reporting system. The vessel failed to report when it had entered WHALESNORTH as defined in 33CFR169.105.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 6 February 2019
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Ships port side lifeboat failed to start.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 19 August 2016
Resolved
1730- Oily Water Seperator -The condition of the ship and its equipment shall be maintained to conform with the provisions of the present convention to ensure that the ship in all respects will remain fit to proceed to sea without presenting an unreasonable threat of harm to the marine environment. OWS failed to operate during Coast Guard exam. MARPOL 1/6.4.1
Engineering › Steam System (main) › Piping
Issued 19 August 2016
Resolved
0999- Steam system -Every steam pipe and every fitting connected thereto which steam may pass shall be so designed, constructed and installed as to withstand the maximum working stresses to which it may be subjected. Steam leak found in engine room forward lower level. SOLAS(04)II-1/33.1
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 20 August 2015
Resolved
0950-Elec Equip in General-Electrical installations shall be such that the safety of the passengers, crew and ship from electrical hazards will be ensured. Vessel has an exposed community distribution board panel in the engine room. 74 SOLAS (14 Cons.) II-1/40.1.3
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 20 August 2015
Resolved
1730-Oily Water Separating Equip-Oil filtering equipment shall be provided and considering the design of such equipment and approvals, the Administration shall have regard to the specification recommended by the Organization. Oil content monitor displays incorrect dates and times. MARPOL 76/78 (2011 Cons.) Annex I/Reg 14.7
Construction/Loadline › Hull › Transverse Frame
Issued 25 July 2011
Resolved
0981- After any survey of the ship, no change shall be made in the structural arrangements. There is a hull dent (5cm deep x 60cm wide x 80cm long), in deck 3, hold 2, starboard side, at frames 146-147. The crew has cut a section of the movable deck to clear the bent frame. 74SOLAS(09 cons)Ch. I/Reg. II (b)
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.