ST. PETER

ST. PETER is a freight ship. The Coast Guard has recorded 8 inspections since 2010, most recently in December 2020, along with 3 deficiencies and 2 operational controls.

Records from 2010 to 2020. Most recent: inspection, 26 December 2020.

Built
Not recorded
Last inspected
26 December 2020
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9437529 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1060624
Flag
BAHAMAS, THE
—
Maury page id
psix-1060624

Inspections, by type

…with no type recorded3
Years with a record 4 calendar years (2010–2020)
The 8 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it20748 - Convention (Subpart B), Gross Ton
32688 - Dead Weight, Ton
43770 - Displacement, Ton
11689 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 8

26 December 2020 PSC B · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7113365
18 December 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7113622
2 April 2018 Ballast Water Examination · ISPS II Exam · Deficiency Check · PII Safety Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6376514
29 July 2016 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5949620
26 July 2016 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5953349
12 October 2010 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3870027
9 October 2010 ISPS I Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3866784
9 October 2010 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3866840

Deficiency record · 3

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 26 December 2020 Resolved
FIRE PROTECTION SYSTEMS AND FIRE FIGHTING SYSTEMS AND APPLIANCES SHALL BE MAINTAINED READY FOR USE. PSCO OBSERVED WATER MIST SYSTEM DISCHARGE VALVE IN CLOSED POSITION. VALVE WAS OPENED AND SYSTEM TESTED WITH SLOW DRIP OBSERVED FROM VALVE THAT WAS INITIALLY CLOSED.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 27 December 2020
Resolved 28 December 2020
Resolution: Crew overhauled valve. BV attended vessel and conducted satisfactory test of entire system with no discrepancies identified.
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 2 April 2018 Resolved
01 0715 - The company should establish procedures, plans and instructions, including checklist as appropriate for key shipboard operations concerning the safety of the personnel, ship and protection of the environment. Company SMS states vessel fire detection system shall be tested with a device as per FSS. FSS chapter 9.2.3.1.3 states heat detectors shall be certified to operate before temperature exceeds 78 degrees Celsius but not until temperature has exceeded 54 deg C, vessel has no device on board capable of accurately testing to these standards. - ISM(a) 7, 17ac
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 April 2018
Resolution: Vsl aquired heat detecting device and USCG witnessed proper testing.
Fire Fighting › Automatic Sprinkler System › Testing Switches (Alarm/Sprinklers)
Issued 2 April 2018 Resolved
0715 - The function of fixed fire detection and fire alarm systems shall be periodically tested by means of equipment producing hot air at the appropriate temperature. PSCO observed no approved testing devices were on board, crew tested with lighter. - 74 SOLAS(04) 2-II/7.3.2, 17ac
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 April 2018
Resolution: Vessel purchased fire testing equipment.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.