← All vessels
NAVIGATOR PHOENIX
NAVIGATOR PHOENIX is a 2009 tank ship. The Coast Guard has recorded 26 inspections since 2011, most recently in April 2026, along with 9 deficiencies and 8 operational controls.
Records from 2011 to 2026. Most recent: inspection, 2 April 2026.
- Built
- 2009
- Last inspected
- 2 April 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 9 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9407330 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
D5BS9
1060857
Flag
LIBERIA
—
Maury page id
psix-1060857
Inspections, by type
…with no type recorded9
Years with a record
11 calendar years (2011–2026)
The 26 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it5343 - Convention (Subpart B), Net Ton
17807 - Convention (Subpart B), Gross Ton
23618 - Dead Weight, Metric Ton
33004 - Displacement, Metric Ton
17807 - Convention (Subpart B), Gross Ton
23618 - Dead Weight, Metric Ton
33004 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 26
2 April 2026
PSC B · COC-GAS Annual
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8334208
22 April 2025
Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8117171
22 March 2025
COC-GAS Renew · PSC B · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8094746
17 March 2023
COC-GAS Renew · ISM Exam · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7645603
26 May 2020
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6961846
26 May 2020
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6963433
22 May 2020
COC-GAS Renew · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6955125
17 August 2018
Administrative Inspection · Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6514799
23 July 2018
ISPS II Exam · COC-GAS Renew · Ballast Water Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6488380
1 September 2017
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6257125
9 December 2016
NPV Safety Exam
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6055235
29 November 2016
COC-GAS Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6045450
6 January 2016
ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5790013
6 January 2016
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5792249
17 October 2015
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5744861
27 August 2015
Type not recorded
No type recorded · Station Port Aransas · USCG Heartland District (CGD-H) · Activity 5227861
21 August 2015
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5222474
12 June 2014
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4886726
14 May 2014
COE-Offshore · ISPS II Exam · COC-GAS Renew · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4853388
2 May 2012
ISPS II Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4301930
2 December 2011
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4200700
2 December 2011
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4202511
2 December 2011
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4258722
22 August 2011
Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4123720
25 July 2011
COE-Offshore · ISPS II Exam · COC-GAS Renew
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4094011
22 July 2011
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4090942
Deficiency record · 9
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 30 March 2025
Resolved
Electrical instllations should be such as to minimize the risk of fire and explosion from flammable products. Permanent repairs as per ABS class report shall be conducted.
74SOLAS(20)VII/13.1
IGC Code 10.1.2
40ac
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 17 March 2023
Resolved
Gas detection equipment acceptable to the administration and suitable for the gases to be carried should be provided in accordance with column F in the Table of Chapter 19.
When PSCOs attempted to observe testing of the installed ammonia NH3 sensor it was discovered there was no test gas available on board.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 17 March 2023
Resolved
The Safety Management System should include procedures ensuring that non-conformities and hazardous situations are reported to the company and investigated and analyzed to improve safety and pollution prevention.
On 28 OCT22 Autronica Fire & Security AS installed a new NH3 sensor. The invoice states that at completion of the install there was no test gas for NH3 on board and that initial sensor calibration must be performed when test gas is on board.
A requisition was created and test gas was expected to be received 08NOV2022. The test gas was not received and a non-conformity was raised by the crew 30 days later on 08DEC2022 using SMS Form ID#08-12-2022/Other/SMT documenting the non-conformity.
On 11FEB2023 the crew performed SMS quarterly maintenance procedure WOU.NPH.2022.004798 and documented in the findings that the NH3 sensor testing could not be performed due to no test gas on board. On 17MAR2023 PSCOs found that test gas was not on board while witnessing gas detection system testing.
Vessel has been operating from 28OCT2022-17MAR2023 without having acquired test gas to properly calibrate NH3 sensor. Vessel has conducted numerous NH3 cargo operations during this time period. An expanded ISM Exam was conducted. Deficiencies 1 and 2 provide objective evidence that revealed a possible major non-conformity of ISM Code 9.1. An external audit is required focusing on ISM Code 9.
CITE: ISM Code 9.1
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 July 2018
Resolved
Cables and wiring shall be supported in such a manner as to avoid chafing and other damage. PSCO found the electrical cable support in way of the aft area of the cross over area for the light fixture were wasted away.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 July 2018
Resolved
where cables are installed in hazardous areas introduce the risk of fire or explosion in the event of an electrical fault special precautions against such risks shall be taken. PSCO found the electrical cable for the 98% Hi level alarm (port dock tank) was separated from the electrical box connector and the electrical covering was damaged at att loop.
Engineering › Diesel Engine (propulsion-electric) › Block
Issued 9 December 2016
Resolved
Vessel reported that when it starts the engine from stop to dead slow ahead, the remote operations from the navigation bridge are not working properly and has to be controlled from the engine room.
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 14 May 2014
Resolved
Pressure relief valves should be tested to ensure that the valves have the capacity required. Vessel's relief valves have passed there calibration period and need to be retested at the vessel's drydock.
Operations/Management › Ballast Water Managment › Mandatory Practices
Issued 14 May 2014
Resolved
Remove fouling organisms from vessel's hull. Vessel's hull had substantial organism growth as witnessed by U.S. Coast Guard Dive team and PSC.
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 22 July 2011
Resolved
Suitable equipment and span gas shall be carried on board for calibration and testing of gas detection system. Span gas found to be expired. SOLAS 2009 (Consiladated) VII/13.1 IGC Code 13.6.6.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.