MAURY USCG vessel records Sign in
← All vessels

NAVIGATOR PHOENIX

NAVIGATOR PHOENIX is a 2009 tank ship. The Coast Guard has recorded 26 inspections since 2011, most recently in April 2026, along with 9 deficiencies and 8 operational controls.

Records from 2011 to 2026. Most recent: inspection, 2 April 2026.

Built
2009
Last inspected
2 April 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9407330 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1060857
Flag
LIBERIA
—
Maury page id
psix-1060857

Inspections, by type

…with no type recorded9
Years with a record 11 calendar years (2011–2026)
The 26 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it5343 - Convention (Subpart B), Net Ton
17807 - Convention (Subpart B), Gross Ton
23618 - Dead Weight, Metric Ton
33004 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 26

2 April 2026 PSC B · COC-GAS Annual
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8334208
22 April 2025 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8117171
22 March 2025 COC-GAS Renew · PSC B · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8094746
17 March 2023 COC-GAS Renew · ISM Exam · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7645603
26 May 2020 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6961846
26 May 2020 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6963433
22 May 2020 COC-GAS Renew · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6955125
17 August 2018 Administrative Inspection · Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6514799
23 July 2018 ISPS II Exam · COC-GAS Renew · Ballast Water Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6488380
1 September 2017 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6257125
9 December 2016 NPV Safety Exam
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6055235
29 November 2016 COC-GAS Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6045450
6 January 2016 ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5790013
6 January 2016 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5792249
17 October 2015 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5744861
27 August 2015 Type not recorded
No type recorded · Station Port Aransas · USCG Heartland District (CGD-H) · Activity 5227861
21 August 2015 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5222474
12 June 2014 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4886726
14 May 2014 COE-Offshore · ISPS II Exam · COC-GAS Renew · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4853388
2 May 2012 ISPS II Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4301930
2 December 2011 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4200700
2 December 2011 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4202511
2 December 2011 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4258722
22 August 2011 Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4123720
25 July 2011 COE-Offshore · ISPS II Exam · COC-GAS Renew
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4094011
22 July 2011 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4090942

Deficiency record · 9

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 30 March 2025 Resolved
Electrical instllations should be such as to minimize the risk of fire and explosion from flammable products. Permanent repairs as per ABS class report shall be conducted. 74SOLAS(20)VII/13.1 IGC Code 10.1.2 40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 April 2025
Resolution: Received class report attesting to satisfactory permanent repair.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 17 March 2023 Resolved
Gas detection equipment acceptable to the administration and suitable for the gases to be carried should be provided in accordance with column F in the Table of Chapter 19. When PSCOs attempted to observe testing of the installed ammonia NH3 sensor it was discovered there was no test gas available on board.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 24 March 2023
Resolution: Vessel submitted flag state dispensation for gas detection system, along with risk assessment, and adequate testing procedures with portable meters.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 17 March 2023 Resolved
The Safety Management System should include procedures ensuring that non-conformities and hazardous situations are reported to the company and investigated and analyzed to improve safety and pollution prevention. On 28 OCT22 Autronica Fire & Security AS installed a new NH3 sensor. The invoice states that at completion of the install there was no test gas for NH3 on board and that initial sensor calibration must be performed when test gas is on board. A requisition was created and test gas was expected to be received 08NOV2022. The test gas was not received and a non-conformity was raised by the crew 30 days later on 08DEC2022 using SMS Form ID#08-12-2022/Other/SMT documenting the non-conformity. On 11FEB2023 the crew performed SMS quarterly maintenance procedure WOU.NPH.2022.004798 and documented in the findings that the NH3 sensor testing could not be performed due to no test gas on board. On 17MAR2023 PSCOs found that test gas was not on board while witnessing gas detection system testing. Vessel has been operating from 28OCT2022-17MAR2023 without having acquired test gas to properly calibrate NH3 sensor. Vessel has conducted numerous NH3 cargo operations during this time period. An expanded ISM Exam was conducted. Deficiencies 1 and 2 provide objective evidence that revealed a possible major non-conformity of ISM Code 9.1. An external audit is required focusing on ISM Code 9. CITE: ISM Code 9.1
Action required: 30 - Ship detained
Resolved 24 March 2023
Resolution: Vessel submitted an SMS Audit report from flag state.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 July 2018 Resolved
Cables and wiring shall be supported in such a manner as to avoid chafing and other damage. PSCO found the electrical cable support in way of the aft area of the cross over area for the light fixture were wasted away.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2018
Resolved 17 August 2018
Resolution: Repaired / Rectified: Cable supports were bolted to the pipe support structures. The cables were fixed to these new supports.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 July 2018 Resolved
where cables are installed in hazardous areas introduce the risk of fire or explosion in the event of an electrical fault special precautions against such risks shall be taken. PSCO found the electrical cable for the 98% Hi level alarm (port dock tank) was separated from the electrical box connector and the electrical covering was damaged at att loop.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2018
Resolved 17 August 2018
Resolution: Repaired / Rectified: The cable was reinstalled in the EEx proof cable gland as required. The outer detoriated insulation was repaired.
Engineering › Diesel Engine (propulsion-electric) › Block
Issued 9 December 2016 Resolved
Vessel reported that when it starts the engine from stop to dead slow ahead, the remote operations from the navigation bridge are not working properly and has to be controlled from the engine room.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 December 2016
Resolved 10 December 2016
Resolution: The complete processing unit for the engine has been replaced with a new unit supplied by the OEM. The new unit has been suitably re-programmed as per manufacturer specifications and tested according to manufacturer protocols.
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 14 May 2014 Resolved
Pressure relief valves should be tested to ensure that the valves have the capacity required. Vessel's relief valves have passed there calibration period and need to be retested at the vessel's drydock.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 August 2014
Resolution: Received class report and photos of corrective actions takin while in dry dock.
Operations/Management › Ballast Water Managment › Mandatory Practices
Issued 14 May 2014 Resolved
Remove fouling organisms from vessel's hull. Vessel's hull had substantial organism growth as witnessed by U.S. Coast Guard Dive team and PSC.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 August 2014
Resolution: Received Cass report and photos of corrective actions takin while in dry dock
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 22 July 2011 Resolved
Suitable equipment and span gas shall be carried on board for calibration and testing of gas detection system. Span gas found to be expired. SOLAS 2009 (Consiladated) VII/13.1 IGC Code 13.6.6.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2011
Resolved 22 August 2011
Resolution: Sector Delaware Bay received delivery receipt confirming delivery of required span gas.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.