NAVIGATOR PHOENIX is a 2009 tank ship. The Coast Guard has recorded 14 inspections since 2016, most recently in April 2026, along with 6 deficiencies and 2 operational controls.
Records from 2016 to 2026. Most recent: inspection, 2 April 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it5343 - Convention (Subpart B), Net Ton 17807 - Convention (Subpart B), Gross Ton 23618 - Dead Weight, Metric Ton 33004 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 14
2 April 2026PSC B · COC-GAS Annual
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8334208
22 April 2025Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8117171
22 March 2025COC-GAS Renew · PSC B · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8094746
17 March 2023COC-GAS Renew · ISM Exam · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7645603
26 May 2020Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6961846
26 May 2020Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6963433
22 May 2020COC-GAS Renew · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6955125
17 August 2018Administrative Inspection · Deficiency Check
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 30 March 2025Resolved
Electrical instllations should be such as to minimize the risk of fire and explosion from flammable products. Permanent repairs as per ABS class report shall be conducted.
74SOLAS(20)VII/13.1
IGC Code 10.1.2
40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 April 2025
Resolution: Received class report attesting to satisfactory permanent repair.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 17 March 2023Resolved
Gas detection equipment acceptable to the administration and suitable for the gases to be carried should be provided in accordance with column F in the Table of Chapter 19.
When PSCOs attempted to observe testing of the installed ammonia NH3 sensor it was discovered there was no test gas available on board.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 24 March 2023
Resolution: Vessel submitted flag state dispensation for gas detection system, along with risk assessment, and adequate testing procedures with portable meters.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 17 March 2023Resolved
The Safety Management System should include procedures ensuring that non-conformities and hazardous situations are reported to the company and investigated and analyzed to improve safety and pollution prevention.
On 28 OCT22 Autronica Fire & Security AS installed a new NH3 sensor. The invoice states that at completion of the install there was no test gas for NH3 on board and that initial sensor calibration must be performed when test gas is on board.
A requisition was created and test gas was expected to be received 08NOV2022. The test gas was not received and a non-conformity was raised by the crew 30 days later on 08DEC2022 using SMS Form ID#08-12-2022/Other/SMT documenting the non-conformity.
On 11FEB2023 the crew performed SMS quarterly maintenance procedure WOU.NPH.2022.004798 and documented in the findings that the NH3 sensor testing could not be performed due to no test gas on board. On 17MAR2023 PSCOs found that test gas was not on board while witnessing gas detection system testing.
Vessel has been operating from 28OCT2022-17MAR2023 without having acquired test gas to properly calibrate NH3 sensor. Vessel has conducted numerous NH3 cargo operations during this time period. An expanded ISM Exam was conducted. Deficiencies 1 and 2 provide objective evidence that revealed a possible major non-conformity of ISM Code 9.1. An external audit is required focusing on ISM Code 9.
CITE: ISM Code 9.1
Action required: 30 - Ship detained
Resolved 24 March 2023
Resolution: Vessel submitted an SMS Audit report from flag state.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 July 2018Resolved
Cables and wiring shall be supported in such a manner as to avoid chafing and other damage. PSCO found the electrical cable support in way of the aft area of the cross over area for the light fixture were wasted away.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2018
Resolved 17 August 2018
Resolution: Repaired / Rectified: Cable supports were bolted to the pipe support structures.
The cables were fixed to these new supports.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 July 2018Resolved
where cables are installed in hazardous areas introduce the risk of fire or explosion in the event of an electrical fault special precautions against such risks shall be taken. PSCO found the electrical cable for the 98% Hi level alarm (port dock tank) was separated from the electrical box connector and the electrical covering was damaged at att loop.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2018
Resolved 17 August 2018
Resolution: Repaired / Rectified: The cable was reinstalled in the EEx proof cable gland as required.
The outer detoriated insulation was repaired.
Vessel reported that when it starts the engine from stop to dead slow ahead, the remote operations from the navigation bridge are not working properly and has to be controlled from the engine room.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 December 2016
Resolved 10 December 2016
Resolution: The complete processing unit for the engine has been replaced with a new unit supplied by the
OEM. The new unit has been suitably re-programmed as per manufacturer specifications and tested according to manufacturer protocols.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.