← All vessels
DAS
DAS is a 2009 tank ship. The Coast Guard has recorded 18 inspections since 2010, most recently in January 2026, along with 8 deficiencies and 3 operational controls.
Records from 2010 to 2026. Most recent: inspection, 4 January 2026.
- Built
- 2009
- Last inspected
- 4 January 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 8 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9439802 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7CT4
1060951
Flag
MARSHALL ISLANDS
—
Maury page id
psix-1060951
Inspections, by type
…with no type recorded2
Years with a record
14 calendar years (2010–2026)
The 18 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it29905 - Convention (Subpart B), Gross Ton
49999 - Dead Weight, Metric Ton
60715 - Displacement, Metric Ton
13429 - Convention (Subpart B), Net Ton
49999 - Dead Weight, Metric Ton
60715 - Displacement, Metric Ton
13429 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 18
4 January 2026
Administrative Inspection · COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8289823
28 November 2025
ISPS Exam
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8274824
27 November 2024
PSC B · COC-CHEM & TVE Annual
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8037902
1 December 2023
PSC B · COC-TVE Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7830728
14 February 2022
Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7396061
27 January 2022
PSC B · COC-CHEM & TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7385894
6 January 2021
PSC B · COC-CHEM & TVE Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7118945
12 November 2020
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7094347
20 April 2020
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6941333
26 February 2020
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6915942
6 December 2019
PII Safety Exam · COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6868729
30 July 2018
ISPS II Exam · COC-CHEM & TVE Annual · Ballast Water Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6491109
10 May 2018
ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6410875
9 July 2017
ISPS II Exam · Ballast Water Examination · COC-CHEM Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6202576
26 August 2015
COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5226657
14 May 2014
Ballast Water Examination · COC-CHEM & TVE Renew · ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4856341
19 May 2012
COC-CHEM Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4315389
2 October 2010
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3857123
Deficiency record · 8
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 27 January 2022
Resolved
SUCH SPACES SHALL BE FITTED WITH PERMANENT GAS SAMPLING, PSCO IDENTIFIED THAT THE FIXED GAS SAMPLING TO VOID SPACE #34 IS BLOCKED. THROWING A FAULT CODE TO GAS DETECTIN PANEL. (SOLAS (AM) II-2/4.5.7.2.2) (40ac)
02 - Structural Conditions › N/A - No Subsystem › Cargo tank vent system
Issued 27 January 2022
Resolved
FOR TANKERS 20,000 TONNES DEAD-WEIGHT SHALL BE IAW FSS CODE. PSCO IDENTIFIED THAT SITE GLASS ON PV BREAKER HAS BEEN REPLACED WITH ACROLIC HOSE REQUEST CLARIFICATION FROM CERTIFICATE ISSUING AUTHROITY TO THE CONTINUING ACCEPTANCE. (SOLAS (AM) II-2/5.5) (40ac)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 January 2021
Resolved
Where the specific cargo is liable to damage the materials normally used in electrical apparatus, due consideration shall be given to the particular characteristics of the materials chosen for conductors, installation, metal parts, etc. As far as necessary, these components shall be protected to prevent contact with gases or vapors liable to be encountered.
Four explosion proof lights were found on the cargo deck with loose wiring. Three of the lights had loose packing glands on the light fixtures. One light had a packing gland that was disconnected. Instead, the light and cabling was held together by blue electrical tape. Lights and cabling were not installed properly therefore potentially allowing for contact with gases or vapors.
74 SOLAS (14) VII/10.1
IBC Code 10.1.2.2
Ref IEC 60092-502: 1999
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 6 January 2021
Resolved
The company and the ship shall comply with the requirement of the international safety management code. And meeting the requirement, the company should ensure that any non-conformity is reported, with its possible cause, if known (10.2.2) and appropriate corrective action is taken (10.2.3)
In accordance with the vessel safety management system QHSE 4.2.1 plan maintenance system, the primary objective of the PMS is to improve effectiveness of maintenance. In accordance with PMS job check explosion proof lighting equipment for component 850.95.08 (Explosion proof light), Check for proper sealing of cable glands.
As delineated in deficiency one, objective evidence attest to the vessel’s crew failing to properly conduct maintenance and inspections of electrical equipment.
An internal safety audit and corrective action within three months is reccommended.
74 SOLAS (14) IX/3.1
ISM Code 10.2
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 7 December 2019
Resolved
06199 - Each vessel vapor connection flange face must have a permeant stud projecting outward 1" long. It must be located at the top of the flange face, midway between bolt holes, and in line with the bolt hole pattern. Stud was not permanently affixed and was not located at the top of the flange face. 46 CFR 39.2001 (j).
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other cargo/timber/deck/construction
Issued 30 July 2018
Resolved
Cargo was identified in the #6 port ballast tank originating from #6 port cargo tank. Ballast tank was entered by ship's crew where 8-10 liters of cargo (gasoline) was found eminating from a possible crack on longitudinal bulkhead of #6 port cargo tank 4M forward of slop tank.
Documentation › Markings/Placards › Warning Signs
Issued 9 July 2017
Resolved
Both the High-Level and Overfill level alarm signage was not readable due to the background not being white.
Deck/Cargo › Inert Gas System › IGS Scrubber
Issued 14 May 2014
Resolved
01-1835-The cooling water arrangements shall be such that an adequate supply of water will always be available without interfering with any essential services on the ship. PSC Officer noted 02 temp. repairs on the cooling side of the Inert Gas Scrubber. - 74SOLAS (04 CONS) II-2/4.5.5.1.2 FSS Code 15/2.2.2.1 - 16b
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.