MAURY USCG vessel records Sign in
← All vessels

SEAWAYS OAK

SEAWAYS OAK is a 2009 tank ship. The Coast Guard has recorded 14 inspections since 2011, most recently in November 2025, along with 6 deficiencies and 3 operational controls.

Records from 2011 to 2025. Most recent: inspection, 26 November 2025.

Built
2009
Last inspected
26 November 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9410014 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1061631
Flag
LIBERIA
—
Maury page id
psix-1061631

Inspections, by type

…with no type recorded2
Years with a record 9 calendar years (2011–2025)
The 14 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it51260 - Dead Weight, Metric Ton
30010 - Convention (Subpart B), Gross Ton
13579 - Convention (Subpart B), Net Ton
61315 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 14

26 November 2025 COC-CHEM & TVE Annual · PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8273475
17 October 2024 PSC B · COC-CHEM & TVE Renew
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8020239
22 November 2023 PSC B · COC-CHEM & TVE Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7826697
18 September 2022 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7558207
17 February 2022 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7398215
15 February 2022 Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7396321
23 December 2021 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7371915
23 September 2021 Ballast Water Examination · PSC B · COC-CHEM & TVE Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7316398
14 July 2020 COC-TVE Renew · MARPOL Annex VI Survey · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7005923
12 July 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7003894
4 March 2018 ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6359797
27 February 2012 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4251580
24 February 2012 Ballast Water Examination · ISPS II Exam · COC-CHEM Renew
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4248252
1 February 2011 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3937262

Deficiency record · 6

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 November 2023 Resolved
Electrical installations shall be such that; all electrical auxiliary services necessary for maintaining the ship in normal operational and habitable conditions will be ensured without recourse to the emergency source of electrical power. PSCO observed wire run through the back of the emergency generator 440V switchboard providing power to high pressure hydroblaster resulting in an unauthorized connection. 74 SOLAS (74), II-1/40.1.1, Deficiency Rectified, Code 10c.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 22 November 2023
Resolved 22 November 2023
Resolution: Ship's crew removed wire and returned system to normal.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 November 2023 Resolved
Main and emergency switchboards shall be so arranged as to give easy access as may be needed to apparatus and equipment, without danger to personnel. The sides and the rear and, where necessary, the front of switchboards shall be suitably guarded. PSCO observed rear panel doors open on 440V emergency generator switchboard. 74 SOLAS (04), II-1/45.2, Deficiency Rectified, Code 10c.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 22 November 2023
Resolved 22 November 2023
Resolution: Ship's crew secured rear panel doors on 440V emergency generator switchboard.
Lifesaving › Lifeboat › Self-contained Air Support System
Issued 4 March 2018 Resolved
0610-Lifeboats-The system shall have visual indicators to indicate the pressure of the air supply at all times. PSCO observed air leaking from O2 supply lines on both lifeboats. 74 SOLAS(14) III/31.1.6/LSA CODE 4.8 (17a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 March 2018
Resolution: 5 MAR 18: Received class report from LR satisfying the requirements of the deficiency issued on 5 MAR 18.
Documentation › Manuals/Policy Documentation › Cargo/Ballast System Instruction Manual
Issued 4 March 2018 Resolved
1840-Instrumentaion-Detailed instruction manuals shall be provided on board, covering the operations, safety and maintenance requirements and occupational health hazards relevant to the inert gas system. PSCO observed that the vessel does not have the correct manuals to calibrate IGS oxygen meter. 74 SOLAS(14) II-2/4.5.5.1.2/FSS CODE 15.2.4.4 (
Action required: 705 - Other - as specified
Due 18 March 2018
Resolved 5 March 2018
Resolution: 5 MAR 18: Received class report from LR satisfying the requirements of the deficiency issued on 5 MAR 18.
Construction/Loadline › Markings › Load Line Mark
Issued 4 March 2018 Resolved
1220-Freeboard Marks-The ring, lines and letters shall be painted in white or yellow on a dark ground or in black on a light ground. PSCO observed load line markings on both sides of the ship have all of the paint rubbed off and barely visible. LOAD LINES Reg. 8 (16a)
Action required: 705 - Other - as specified
Due 18 March 2018
Resolved 5 March 2018
Resolution: 5 MAR 18: Received class report from LR satisfying the requirements of the deficiency issued on 5 MAR 18.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 24 February 2012 Resolved
Any ship of 10000 gross tons and above shall be fitted with an oily water seperator complying with paragraph 7 of this regulation. Oily water seperator sensor desiccator was faulty and required replacement. Provide class report once unit is operational. MARPOL Annex I Regulation 14
Action required: 705 - Other - as specified
Resolved 25 February 2012
Resolution: Vessel provided a class report for the renewed OWS oil content meter faulty sensor. Statement indicates that the OWS equipment is in good working condition.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.