Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it17972 - Displacement, Metric Ton 12709 - Dead Weight, Metric Ton 9627 - Convention (Subpart B), Gross Ton 4261 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 20 October 2025Resolved
FLAME DETECTORS SHALL BE TESTED ACCORDING TO STANDARDS EN 54-10:2001. PSCE OBSERVED ELEC. USING OPEN FLAME TO TEST FLAME DETECTORS. CREW HAS REQUESTED TO RECEIVE PROPER TESTING EQUIPMENT FROM COMANY IN 2024. CREW HAS ISSUED ANOTHER PROCUREMENT FOR REQUEST OF TESTING EQUIPMENT. 74 SOLAS(09) II-2/ 7.2.3 AND FSS 9.2.3.1.5
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2025
Resolved 10 November 2025
Resolution: Extended for Class attendance on November 7th at Freeport, TX.The vessel is equipped with a certified UV Flame Detector Test Kit, proper testing procedures in accordance with EN 54-10 and FSS Code have been reinstated.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 20 October 2025Resolved
THE COMPANY IS RESPONSIBLE FOR ENSURING THAT ADEQUATE RESOURCES ARE PROVIDED.COMPANY HAS NOT ISSUED PROPER FLAME DETECTOR TESTING EQUIPMENT AFTER VESSEL REQUESTED. 74 SOLAS (20) IX/3.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2025
Resolved 10 November 2025
Resolution: Extended for Class attendance on November 7th at Freeport, TX. The vessel is equipped with a certified UV Flame Detector Test Kit, proper testing procedures in accordance with EN 54-10 and FSS Code have been reinstated.