PALERMO is a tank ship. The Coast Guard has recorded 13 inspections since 2016, most recently in May 2022, along with 3 deficiencies and 3 operational controls.
Records from 2016 to 2022. Most recent: inspection, 24 May 2022.
This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it53540 - Dead Weight, Metric Ton 60213 - Displacement, Metric Ton 31510 - Convention (Subpart B), Gross Ton 14001 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 13
24 May 2022PSC B · COC-TVE Annual
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7455185
20 February 2022Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7399142
16 February 2022Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7397152
9 April 2021PSC B · COC-TVE Renew · Ballast Water Examination
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 May 2022Resolved
No electrical equipment shall be installed in any space where flammable mixtures are liable to collect including those on board tankers, unless the administration is satisfied that such equipment is appropriately certified for safe usage in the dusts, vapours or gases likely to be encountered. PSCO observed 01 light fixture caseing on second deck in cargo pump room with a crack fully through its lense.
74 SOLAS (2020)II-1/45.10.4, 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 24 May 2022
Resolved 24 May 2022
Resolution: Crew replaced cracked lens with a new one, prior to PSCO departing vessel.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 24 May 2022Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO observed #6 foam monitor valve not operational. Crew was able to fix prior to PSCO departure.
74 SOLAS(2020)II-2/14.2.1.2, 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 24 May 2022
Resolved 24 May 2022
Resolution: Crew was able to fix the opening valve prior to PSCO departure.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 2 December 2018Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present convention to ensure that the ship...remain fit to proceed to sea without presenting an unreasonable threat of harm to the marine environment. PSCO and Marine Chemist observed strong smell of gasoline in vicinity of AUS Tanks and vacuum pumps. Marine Chemist detected 1.6 PPM in vicinity of #3 AUS Tank.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 December 2018
Resolution: Received class report identifying repair of leaking valve.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National