MAURY USCG vessel records Sign in
← All vessels

FT GAINES

FT GAINES is a 1970 passenger vessel (inspected). The Coast Guard has recorded 62 inspections since 1985, most recently in March 2026, along with 44 deficiencies.

Records from 1985 to 2026. Most recent: inspection, 4 March 2026.

Built
1970
Last inspected
4 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDB8419
106258
Flag
UNITED STATES
367740360
Maury page id
psix-106258

Inspections, by type

…with no type recorded3
Years with a record 30 calendar years (1985–2026)
The 62 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)113.5 ft × 34.0 ft × 8.0 ft
Registered tonnagegross 88 / net 60
ITC dimensions (L × B × D)113.5 ft × 34.0 ft × 8.0 ft
ITC tonnagegross 172 / net 61
BuilderNEW BERN SHIPYARD INC · NEW BERN, NC, UNITED STATES · built 1970
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPEAKS ISLAND, ME
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 22 November 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it88 - Regulatory (Subpart C or D), Gross Ton
172 - Convention (Subpart B), Gross Ton
60 - Regulatory (Subpart C or D), Net Ton
61 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDI8614MMSI 367740360 · active · compulsorily equipped · granted 13 June 2026, expires 14 June 2036
WUR9819MMSI 366977060 · cancelled · compulsorily equipped · granted 10 September 2004, cancelled 22 March 2006 · licensed under a name not among this hull’s recorded names (not shown)
WDB8419MMSI 366958370 · expired · compulsorily equipped · granted 22 June 2004, cancelled 23 August 2014
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 62

4 March 2026 Drydock Exam · Internal Structural Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8338730
23 December 2025 Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8283670
18 December 2024 Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8049604
28 February 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7873534
20 December 2023 Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7841089
17 October 2023 Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7809866
4 October 2023 Internal Structural Exam · Administrative Inspection · In-Service Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7803969
2 December 2022 Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7604149
10 January 2022 COI Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7377959
27 July 2021 Drydock Exam · Internal Structural Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7269763
14 January 2021 Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7124561
13 November 2020 In-Service Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7094650
26 August 2020 Drydock Extension
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7058299
14 January 2020 Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6887121
27 March 2019 Administrative Inspection · Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6651266
11 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6538078
21 August 2018 Administrative Inspection · Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6519397
25 January 2018 Administrative Inspection · Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6344032
2 November 2016 COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6056941
27 July 2016 Drydock Exam · Administrative Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6057884
4 November 2015 Administrative Inspection · COI Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5782685
22 October 2014 Administrative Inspection · Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5014876
8 December 2010 Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3906965
1 November 2010 Hull Examination
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3882352
7 January 2010 Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3656752
22 January 2009 Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3392781
27 October 2008 Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3340816
23 October 2007 In-Service Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3084729
25 July 2007 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3006760
2 July 2007 Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2980964
16 April 2007 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2908780
16 December 2003 Deadweight Survey · Internal Structural Exam · Examination of Repairs · COI Inspection · Hull Examination · Plan Review "T" Boat
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1965245
12 August 2003 Administrative Inspection
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1874375
12 November 1997 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 788082
25 August 1997 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 785561
12 May 1997 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1434558
24 February 1997 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1400498
24 July 1996 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1374686
21 May 1996 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1360512
26 February 1996 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1385647
28 August 1995 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1185706
6 June 1995 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1186101
28 February 1995 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1392173
10 November 1994 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 863053
28 September 1994 Hull Examination · Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1382833
10 March 1994 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1359743
22 June 1993 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 847090
26 March 1993 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1153491
24 February 1993 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1147586
20 May 1992 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 952588
6 April 1992 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1261446
21 October 1991 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 939969
2 April 1991 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1224474
29 March 1991 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1224634
22 March 1991 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1224635
4 October 1990 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 923381
14 March 1989 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1031941
20 October 1988 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1199373
16 March 1987 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1324543
24 February 1987 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1011585
18 March 1986 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 998146
12 March 1985 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 980481

Deficiency record · 44

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 December 2025 Resolved
Segregate and label life jackets. Child lifejackets should be clearly separated from adult lifejackets.
Due 6 January 2026
Resolved 21 January 2026
Resolution: Lifejackets segregated.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 December 2025 Resolved
Remove/ box off dead end wires on bridge.
Due 6 January 2026
Resolved 21 January 2026
Resolution: Dead end wires placed in junx box.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 December 2025 Resolved
Captain could not provide portable lighting. Provide portable lighting for bridge and engine room. (flashlights)
Due 6 January 2026
Resolved 21 January 2026
Resolution: Portable flashlights provided.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 23 December 2025 Resolved
Provide training on use of electronic bell or provide mechanical bell.
Due 6 January 2026
Resolved 21 January 2026
Resolution: Traditional Mechanical bell installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 17 October 2023 Resolved
Missed DDX drop-dead date: 46 CFR 176.600 (C)(1) A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 April 2024
Resolved 26 April 2024
Resolution: Credit DD completed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 14 January 2021 Resolved
A hatch cover must have: securing devices; and Be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent loss. -Current condition does not meet the reg.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2021
Resolved 26 February 2021
Resolution: Lanyards installed
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 January 2021 Resolved
The master shall have appropriate “NO SMOKING” signs posted and shall take all necessary precautions to prevent smoking or carrying of lighted or smoldering pipes, cigars, cigarettes, or similar items in the deck area assigned to automobiles or other vehicles. -Current condition does not meet the reg.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2021
Resolved 26 February 2021
Resolution: Signs posted
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 January 2021 Resolved
Each distribution line valve of a fixed gas fire extinguishing system and the fire main, must be plainly, conspicuously, and permanently marked indicating the space served. -Current condition does not meet the reg.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2021
Resolved 26 February 2021
Resolution: Line marked
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 14 January 2021 Resolved
The Bridge-to-Bridge Act and the regulations of this part applies to every power-driven vessel of 20 meters or over in length while navigating. Each vessel must carry a certificate with a valid endorsement while subject to the Bridge-to-Bridge Act. -Unable to provide Bridge-to-Bridge Certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2021
Resolved 6 April 2021
Resolution: B to B cert rcvd
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 November 2020 Resolved
CO2 bottle under required weight.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 14 January 2021
Resolved 14 January 2021
Resolution: CO2 Bottle was replaced by Interstate Fire Systems.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 11 September 2018 Resolved
The vessel is currently broadcasting (1) Zero Length and Beam, (2) Zero Draft, (3) Improper Ship Type, The Ship Type should be 60 per the official encoding guide, vice just the 6 that they are currently using.
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 October 2018
Resolved 1 August 2020
Resolution: Inputs corrected.
Electrical › Electric Supply System (service) › Cable
Issued 8 December 2010 Resolved
Secure bundled electrical cables in engine compartment with metallic supports.
Condition: Improper/Lack of Maintenance
Due 8 January 2011
Resolved 7 January 2011
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 8 December 2010 Resolved
Insufficient adult life preservers for # passengers vessel certificated to carry. 835 written to restrict vessel to carrying only 116 adult passengers and 16 child until sufficient life preservers provided or COI amended. (Vessel O/O intends to amend COI to reduce passenger count.)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 January 2011
Resolved 21 January 2011
Resolution: Passenger count reduced to 100 on COI.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 22 January 2009 Resolved
Provide corrosion resistant clips for all ring life buoys.
Action required: 705 - Other - as specified
Due 22 February 2009
Resolved 4 February 2009
Documentation › Certificates/Documents › FCC SSL
Issued 22 January 2009 Resolved
Provide FCC Radio Safety Certificate.
Action required: 705 - Other - as specified
Due 22 February 2009
Resolved 9 February 2009
Engineering › Shafting/Propeller Arrangements › Strut Bearing
Issued 27 October 2008 Resolved
Replace all three shaft strut bearings and assess the condition of all three stern tube bearings.
Action required: 705 - Other - as specified
Due 30 April 2010
Resolved 12 April 2010
Resolution: Per O/O request, restored hull exam due date to 31OCT10, from 30APR10 as vessel has not been used significantly during the past 18 months, minimizing wear on the center shaft cutlass bearing.
Construction/Loadline › Structures › Door
Issued 30 October 2007 Resolved
Prove proper operation of the E/R WTD.
Action required: 705 - Other - as specified
Due 20 November 2008
Resolved 30 October 2008
Resolution: Performed satisfactory chalk test during dry dock exam Oct 2008.
Construction/Loadline › Structures › Deck Plating
Issued 26 October 2006 Resolved
Provide to the [name withheld] a copy of the Deck Arrangement Main Deck and Above drawing (DWG CE-2017-7, Rev C; dated 10/20/69)
Action required: 705 - Other - as specified
Due 25 November 2006
Resolved 3 November 2006
Resolution: Provided to the [name withheld] a copy of the Deck Arrangement Main Deck and Above drawing (DWG CE-2017-7, Rev C; dated 10/20/69)
Construction/Loadline › Structures › Deck Plating
Issued 26 October 2006 Resolved
Provide to the [name withheld] a copy of the Typical Sections drawing (DWG CE-2017-9, Rev C; dated 10/20/69)
Action required: 705 - Other - as specified
Due 25 November 2006
Resolved 3 November 2006
Resolution: Provided to the [name withheld] a copy of the Typical Sections drawing (DWG CE-2017-9, Rev C; dated 10/20/69)
Construction/Loadline › Structures › Deck Plating
Issued 26 October 2006 Resolved
Provide to the [name withheld] a copy of the Hull Structure drawing (DWG CE-2017-11, Rev D; dated 10/20/69)
Action required: 705 - Other - as specified
Due 25 November 2006
Resolved 3 November 2006
Resolution: Provided to the [name withheld] a copy of the Hull Structure drawing (DWG CE-2017-11, Rev D; dated 10/20/69)
Construction/Loadline › Structures › Deck Plating
Issued 26 October 2006 Resolved
Provide to the [name withheld] a copy of the Bulkheads Below Main Deck drawing (DWG CE-2017-12, Rev D; dated 10/20/69)
Action required: 705 - Other - as specified
Due 25 November 2006
Resolved 3 November 2006
Resolution: Provided to the [name withheld] a copy of the Bulkheads Below Main Deck drawing (DWG CE-2017-12, Rev D; dated 10/20/69)
Construction/Loadline › Structures › Deck Plating
Issued 26 October 2006 Resolved
Provide to the [name withheld] a copy of the Deckhouse Structure and Bulwarks drawing (DWG CE-2017-13, Rev E; dated 10/20/69)
Action required: 705 - Other - as specified
Due 25 November 2006
Resolved 3 November 2006
Resolution: Provided to the [name withheld] a copy of the Deckhouse Structure and Bulwarks drawing (DWG CE-2017-13, Rev E; dated 10/20/69)
Electrical › Electric Generation Source (service) › Power Requirement
Issued 26 October 2006 Resolved
Submit to the USCG Marine Safety Center for review and approval a electrical plant load analysis including connected loads and computed operating loads for each condition of operation as required by 46 CFR 177.202(b)(4) and resolve all outstanding plan review comments to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Due 25 June 2007
Resolved 2 July 2007
Resolution: MSC letter dated 6JUN07 approved AC load analysis
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 26 October 2006 Resolved
Submit to the USCG Marine Safety Center for review and approval all machinery installations to include but not limited to: propulsion and propulsion control, including shaft details; steering and steering control, including rudder details; ventilation diagrams; and engine exhaust diagram as required by 46 CFR 177.202(b)(3) and resolve all outstanding plan review comments
Action required: 705 - Other - as specified
Due 25 March 2007
Resolved 23 February 2007
Resolution: Plans were approved for propulsion and propulsion control, including shaft details; steering and steering control, including rudder details; ventilation diagrams; and engine exhaust diagram
Electrical › Lighting (emergency) › Lighting Branch Circuit
Issued 26 October 2006 Resolved
Submit to the USCG Marine Safety Center for review and approval the DC electrical installation including but not limited to type of capacity of storage batteries; rating of circuit breakers and switches, interrupting capacity of circuit breakers, and rating and setting of overcurrent devices as required by 46 CFR 177.202(b)(4) and resolve all outstanding plan review comments
Action required: 705 - Other - as specified
Due 25 September 2007
Resolved 19 July 2007
Resolution: Received approval letter from MSC dated 5JUL07.
Fire Fighting › Fire Main › Condition
Issued 26 October 2006 Resolved
Submit to the USCG Marine Safety Center for review and approval the fire main system plans and calculations as required by 46 CFR 177.202(b)(6) and resolve all outstanding plan review comments to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Due 25 March 2007
Resolved 23 February 2007
Resolution: Plans were approved addressing the fire main system plans and calculations.
Engineering › Fuel Oil Service System › Piping
Issued 26 October 2006 Resolved
Submit to the USCG Marine Safety Center for review and approval piping systems for hydraulic (ramp only); sanitary; compressed air; combustible and flammable liquids (lube oil & fuel oil); vents; sounds; and overflows as required by 46 CFR 177.202(b)(8) and resolve all outstanding plan review comments to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Due 25 March 2007
Resolved 23 February 2007
Resolution: Plans were approved addressing hydraulic (ramp only); sanitary; compressed air; combustible and flammable liquids (lube oil & fuel oil); vents; sounds; and overflows.
Construction/Loadline › Hull › Bottom Plating
Issued 26 October 2006 Resolved
Submit to the USCG Marine Safety Center for review and approval hull penetrations and shell connections as required by 46 CFR 177.202(b)(9) and resolve all outstanding plan review comments to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Due 25 March 2007
Resolved 23 February 2007
Resolution: Plans were approved addressing hull penetrations and shell connections
Construction/Loadline › Structures › Deck Plating
Issued 26 October 2006 Resolved
Submit to the USCG Marine Safety Center for review and approval the car ramp system structural & mechanical details and calculations as required by 46 CFR 177.202 and resolve all outstanding plan review comments to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Due 25 June 2007
Resolved 2 July 2007
Resolution: MSC letter dated 15JUN07 approved vessel''s ramps.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type 1
Issued 26 October 2006 Resolved
Submit to the USCG Marine Safety Center for review and approval the Marine Sanitation device model number, approval number, connecting wiring, and piping as required by 46 CFR 177.202(b)(10) and resolve all outstanding plan review comments to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Due 25 December 2006
Resolved 13 December 2006
Resolution: Removed requirement, because the MSD was removed from the vessel. The vessel only has a holding tank.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 5 September 2006 Resolved
Clean, Inspect, and return to lifejacket lockers, all life jackets that are stored in the battery storage room for the transit to the Virgin Islands.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 September 2006
Resolved 13 October 2006
Resolution: Cleaned, inspected and properly restowed all lifejackets that were stowed in the battery storage room.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 5 September 2006 Resolved
Remove all items stored in the lifejacket storage lockers located in the passenger lounge. Remove the refrigerator and microwave from the passenger and lifejacket stowage room.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 September 2006
Resolved 13 October 2006
Resolution: Removed the refrigerator and microwave from the passenger lounge. Changed the passenger lounge to a lifejacket storage room and properly labeled.
Documentation
Issued 28 August 1995 Resolved
POST CERTIFICATE OF INSPECTION UNDER GLASS IN A CONSPICUOUS PLACE.
Condition: Unknown
Due 21 September 1995
Resolved 21 September 1995
Lifesaving
Issued 28 August 1995 Resolved
PROVIDE (5) CHILDRENS AND (3) ADULT TYPE I PFD'S AS REQUIRED BY VESSEL'S CERTIFICATE OF INSPECTION.
Condition: Unknown
Due 21 September 1995
Resolved 21 September 1995
Lifesaving
Issued 28 August 1995 Resolved
REPLACE INOPERABLE WATERLIGHT ON MAIN DECK.
Condition: Unknown
Due 21 September 1995
Resolved 21 September 1995
Navigation
Issued 6 June 1995 Resolved
PROVIDE PROCEDURES FOR THE EMERGENCY STEERING CROSSOVER IN THE_x001C_ WHEELHOUSE PRIOR TO THE VESSELS OPERATION.
Condition: Unknown
Due 6 June 1995
Resolved 6 June 1995
Engineering
Issued 6 June 1995 Resolved
REPLACE ALL MDE's REDUCTION GEAR LUBE OIL HOSES THAT ARE WORN THROUGH THE FIRST JACKET PRIOR TO 20JUN95.
Condition: Unknown
Due 6 June 1995
Resolved 6 June 1995
Fire Fighting
Issued 6 June 1995 Resolved
PROVIDE DOCUMENTATION FOR MONTHLY MAINTANANCE OF THE PORTABLE FIRE EXTINGUISHERS PRIOR TO THE VESSELS OPERATION.
Condition: Unknown
Due 6 June 1995
Resolved 6 June 1995
Electrical
Issued 6 June 1995 Resolved
MAKE OPERABLE BOTH MSD MOTOR CONTROLLER DOOR INTERLOCKS PRIOR TO 20JUN95.
Condition: Unknown
Due 6 June 1995
Resolved 6 June 1995
Engineering
Issued 6 June 1995 Resolved
PROVIDE ENGINE ORDER TELEGRAPH PLACARD AT THE ENGINE ROOM CONTROL PRIOR TO THE VESSELS OPERATION.
Condition: Unknown
Due 6 June 1995
Resolved 6 June 1995
Fire Fighting
Issued 22 March 1991 Resolved
PROVIDE SERVICING REPORT FOR PORTABLE AND FIXED FIREFIGHTING SYSTEMS TO [name withheld].
Condition: Unknown
Due 22 March 1991
Resolved 22 March 1991
Documentation
Issued 22 March 1991 Resolved
PROVIDE CURRENT FCC SAFETY RADIOTELEPHONIC CERTIFICATE.
Condition: Unknown
Due 22 March 1991
Resolved 22 March 1991
Documentation
Issued 22 March 1991 Resolved
PROVIDE OIL POLLUTION PLACED IN ENGINEROOM.
Condition: Unknown
Due 22 March 1991
Resolved 22 March 1991
Documentation
Issued 22 March 1991 Resolved
STENCIL EMERGENCY HATCH FOR ENGINEROOM WITH "EMERGENCY ESCAPE KEEP OFF".
Condition: Unknown
Due 22 March 1991
Resolved 22 March 1991

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.