Records from 2016 to 2026. Most recent: inspection, 4 March 2026.
Documentation record
Registered dimensions (L × B × D)113.5 ft × 34.0 ft × 8.0 ft
Registered tonnagegross 88 / net 60
ITC dimensions (L × B × D)113.5 ft × 34.0 ft × 8.0 ft
ITC tonnagegross 172 / net 61
BuilderNEW BERN SHIPYARD INC · NEW BERN, NC, UNITED STATES · built 1970
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPEAKS ISLAND, ME
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 22 November 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it88 - Regulatory (Subpart C or D), Gross Ton
172 - Convention (Subpart B), Gross Ton
60 - Regulatory (Subpart C or D), Net Ton
61 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 20
4 March 2026
Drydock Exam · Internal Structural Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8338730
23 December 2025
Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8283670
18 December 2024
Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8049604
28 February 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7873534
20 December 2023
Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7841089
17 October 2023
Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7809866
4 October 2023
Internal Structural Exam · Administrative Inspection · In-Service Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7803969
2 December 2022
Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7604149
10 January 2022
COI Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7377959
27 July 2021
Drydock Exam · Internal Structural Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7269763
14 January 2021
Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7124561
13 November 2020
In-Service Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7094650
26 August 2020
Drydock Extension
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7058299
14 January 2020
Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6887121
27 March 2019
Administrative Inspection · Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6651266
11 September 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6538078
21 August 2018
Administrative Inspection · Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6519397
25 January 2018
Administrative Inspection · Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6344032
2 November 2016
COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6056941
27 July 2016
Drydock Exam · Administrative Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6057884
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 December 2025
Resolved
Segregate and label life jackets. Child lifejackets should be clearly separated from adult lifejackets.
Due 6 January 2026
Resolved 21 January 2026
Resolution: Lifejackets segregated.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 December 2025
Resolved
Remove/ box off dead end wires on bridge.
Due 6 January 2026
Resolved 21 January 2026
Resolution: Dead end wires placed in junx box.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 December 2025
Resolved
Captain could not provide portable lighting. Provide portable lighting for bridge and engine room. (flashlights)
Due 6 January 2026
Resolved 21 January 2026
Resolution: Portable flashlights provided.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 23 December 2025
Resolved
Provide training on use of electronic bell or provide mechanical bell.
Due 6 January 2026
Resolved 21 January 2026
Resolution: Traditional Mechanical bell installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 17 October 2023
Resolved
Missed DDX drop-dead date: 46 CFR 176.600 (C)(1)
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 April 2024
Resolved 26 April 2024
Resolution: Credit DD completed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 14 January 2021
Resolved
A hatch cover must have: securing devices; and Be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent loss. -Current condition does not meet the reg.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2021
Resolved 26 February 2021
Resolution: Lanyards installed
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 January 2021
Resolved
The master shall have appropriate “NO SMOKING” signs posted and shall take all necessary precautions to prevent smoking or carrying of lighted or smoldering pipes, cigars, cigarettes, or similar items in the deck area assigned to automobiles or other vehicles. -Current condition does not meet the reg.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2021
Resolved 26 February 2021
Resolution: Signs posted
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 January 2021
Resolved
Each distribution line valve of a fixed gas fire extinguishing system and the fire main, must be plainly, conspicuously, and permanently marked indicating the space served. -Current condition does not meet the reg.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2021
Resolved 26 February 2021
Resolution: Line marked
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 14 January 2021
Resolved
The Bridge-to-Bridge Act and the regulations of this part applies to every power-driven vessel of 20 meters or over in length while navigating. Each vessel must carry a certificate with a valid endorsement while subject to the Bridge-to-Bridge Act. -Unable to provide Bridge-to-Bridge Certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2021
Resolved 6 April 2021
Resolution: B to B cert rcvd
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 November 2020
Resolved
CO2 bottle under required weight.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 14 January 2021
Resolved 14 January 2021
Resolution: CO2 Bottle was replaced by Interstate Fire Systems.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 11 September 2018
Resolved
The vessel is currently broadcasting (1) Zero Length and Beam, (2) Zero Draft, (3) Improper Ship Type, The Ship Type should be 60 per the official encoding guide, vice just the 6 that they are currently using.
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 October 2018
Resolved 1 August 2020
Resolution: Inputs corrected.