VISBY is a 2010 freight ship. The Coast Guard has recorded 13 inspections since 2017, most recently in November 2025, along with 12 deficiencies and 3 operational controls.
Records from 2017 to 2025. Most recent: inspection, 21 November 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it22409 - Regulatory (Subpart C or D), Gross Ton 12013 - Regulatory (Subpart C or D), Net Ton 22409 - Convention (Subpart B), Gross Ton 12013 - Convention (Subpart B), Net Ton 44764 - Displacement, Ton 35052 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 13
21 November 2025PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8268521
12 May 2025PSC A
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8129091
9 May 2025Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8131541
9 May 2025Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8131611
10 May 2023Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7685591
10 May 2023Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7710636
6 May 2023Appeal · Administrative Inspection · PSC B
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7682312
25 July 2022Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7515984
25 July 2022Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7518127
21 July 2022PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7512633
10 June 2018ISPS II Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6432263
6 June 2018Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6435760
19 July 2017Ballast Water Examination · NPV Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6205440
11 - Life Saving Appliances › N/A - No Subsystem › Evaluation, testing and approval
Issued 12 May 2025Resolved
Maintenance, testing, and inspection of life-saving appliances shall be carried out. Liferafts with service intervals have exceeded 12 month testing requirement.
74 SOLAS (am) III/20.3.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 May 2025
Resolved 13 May 2025
Resolution: PSC NOLA received a class report from ABS satisfying the requirement.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 12 May 2025Resolved
The following fire protection system shall be kept in good order so as to ensure their required performance if a fire occurs: structural fire protection including fire-resistance divisions and protection of openings and penetrations in these divisions. PSCO observed a gap in the bulkhead of an A-Class boundary as reflected in the fire control plan.
74 SOLAS (am) II-2/14.2.1.1.1
Action required: 17 - Rectify deficiencies prior to departure
Due 12 May 2025
Resolved 13 May 2025
Resolution: PSC NOLA received a class report from ABS satisfying the requirement.
07 - Fire Safety › N/A - No Subsystem › Main Vertical zone
Issued 12 May 2025Resolved
In the case of periodically unattended machinery spaces, the fire-extinguishing system shall have both automatic and manual release capabilities. Fixed local application fire-extinguishing system is unable to be started automatically. Chief Engineer stated the system can only be manually released.
74 SOLAS (am) II-2/10.5.6.2
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Due 12 May 2025
Resolved 14 May 2025
Resolution: Received class report, updated class certificate, and updated safe manning certificate to satisfaction
The transfer procedures required by 155.720 must be avalible for inspection by the COTP or OCMI. Vessel was unable to produce the required Oil Transfer Procedure.
33 CFR 155.740(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2025
Resolved 14 May 2025
Resolution: Received class report attesting to transfer procedures are now available for inspection.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 12 May 2025Resolved
Muster and embarkation stations shall be adequately illuminated by lighting supplied from the emergency source of electrical power. PSCO observed multiple embarkation station emergency lights not in operation.
74 SOLAS (am) III/11.4
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 12 May 2025
Resolved 12 May 2025
Resolution: Bulbs replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 12 May 2025Resolved
Before the ship leaves port and at all times, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed the life boat unable to start.
74 SOLAS (am) III/20.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 12 May 2025
Resolved 12 May 2025
Resolution: Replaced the battery.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 12 May 2025Resolved
A main eletrica lighting system which shall provide illumination throughout those parts of the ship normally accessible to and used by passengers or crew shall be supplied from the main source of eletrical power. PSCO observed numerous inoperable deck lights.
74 SOLAS (am) II-1/41.2.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 12 May 2025
Resolved 12 May 2025
Resolution: Bulbs were replaced.
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WIL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. PSCO OBSERVED A LEAK OF WATER FROM THE STEERING GEAR RUDDER POST AT APPROXIMATELY 1 DRIP PER SECOND. VESSEL PROVIDED DOCUMENTATION ATTESTING TO ISSUE IN NOVEMBER 2022, CORRECTED AT DRYDOCK IN DECEMBER. THE LEAK WAS THEN NOTED BY THE CREW AND REPORTED TO COMPANY IN MARCH 2023. CREW TIGHTENED THE BOLTS AT CONNECTION OF RUDDER STOCK, DRIPPING NO LONGER OBSERVED. 74SOLAS(20) I/11
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 May 2023
Resolution: DEFICIENCY CLEARED AFTER RECEIVING CLASS REPORT AND PSC TEAM CONDUCTING INSPECTION ON REPAIRS.
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. PSCO OBSERVED 11 BALLAST SOUNDING TUBES EXHIBITING SIGNIFICANT CORROSION RENDERING THE SOUNDING TUBE CAPS INOPERABLE. PSCO OBSERVED MULTIPLE GASKETS TO BALLAST TANK COVERS AS BEING SEVERELY DETERIORATED. 74SOLAS(20) I/11
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 May 2023
Resolution: CLASS AND PSC TEAM CONDUCTED INSPECTION ON TEMPORARY REPAIRS ALLOWING VESSEL TIME TO COMPLETE PERMANENT REPAIRS.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 17 May 2023Resolved
THE FIRE RESISTANCE OF DOORS SHALL BE EQUIVALENT TO THAT OF THE DIVISION IN WHICH THEY ARE FITTED, THIS BEING DETERMINED IN ACCORDANCE WITH THE FIRE TEST PROCEDURES CODE...DOORS FITTED IN BOUNDARY BULKHEADS OF MACHINERY SPACES OF CATEGORY A SHALL BE REASONABLY GASTIGHT AND SELF CLOSING. PSCO OBSERVED HOLES THROUGH A60 BOUNDARY FIRE DOOR IN MAIN ENTRANCE TO ENGINE ROOM. 74SOLAS(09)II-2/9.4.2.1
Action required: 30 - Ship detained
Resolved 20 May 2023
Resolution: CLASS AND PSC TEAM CONDUCTED INSPECTION ON TEMPORARY REPAIRS ALLOWING VESSEL TIME TO COMPLETE PERMANENT REPAIRS.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 May 2023Resolved
ALL ELECTRICAL APPARATUS SHALL BE SO CONSTRUCTED AND SO INSTALLED AS NOT TO CAUSE INJURY WHEN HANDLED OR TOUCHED IN THE NORMAL MANNER. PSCO OBSERVED DURING DECK WALK THAT MULTIPLE WIRES FOR CARGO VENTILATION HOLDS ARE DISCONNECTED AND HANGING LOOSELY WITH NO LOCK OUT TAG OUT PROCEDURE VISIBLY BEING FOLLOWED. 74SOLAS(04)II-1/45.1.3
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 May 2023
Resolution: CODE 17 DOWNGRADED TO CODE 50 AFTER CLASS AND PSC TEAM CONDUCTED INSPECTION ON TEMPORARY REPAIRS ALLOWING VESSEL TIME TO COMPLETE PERMANENT REPAIRS.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 17 May 2023Resolved
THE MACHINERY BOILERS AND OTHER PRESSURE VESSELS, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED AND SHALL BE SO INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ON BOARD, DUE REGARD BEING PAID TO MOVING PARTS, HOT SURFACES AND OTHER HAZARDS. PSCO OBSERVED MISSING LAGGING ON PIPING SYSTEMS IN MACHINERY SPACE AND BROKEN GUARDS ON ROTATING MACHINERY IN ENGINE ROOM AND DAVIT SYSTEM ON PORT SIDE MAIN DECK. SOLAS74(04)II-1/26.1
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 May 2023
Resolution: DEFICIENCY CLEARED AFTER RECEIVING CLASS REPORT ATTESTING TO REPAIRS AND PSC TEAM CONDCTING INSPECTION OD REPAIRS.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.