ADVANTAGE SPICE is a tank ship. The Coast Guard has recorded 9 inspections since 2016, most recently in June 2025, along with 3 deficiencies and 1 operational control.

Records from 2016 to 2025. Most recent: inspection, 10 June 2025.

Built
Not recorded
Last inspected
10 June 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 10 June 2025
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9419888
1062677
Flag
MARSHALL ISLANDS
Maury page id
psix-1062677

Documentation record

Tonnage as PSIX records it156643 - Dead Weight, Metric Ton
182538 - Displacement, Metric Ton
83827 - Convention (Subpart B), Gross Ton
49031 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 9

10 June 2025 PSC B · COC-TVE Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8149666
1 August 2022 Deficiency Check · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7522357
25 July 2022 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7515973
22 July 2022 MARPOL Annex VI Survey · PSC B · Ballast Water Examination · COC-TVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7513411
18 May 2022 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7537313
14 June 2021 COC-TVE Renew · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7224958
5 May 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5869338
5 May 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5869698
24 April 2016 ISPS II Exam · COC-TVE Renew · COE-Offshore · Ballast Water Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5857378

Deficiency record · 3

10 - Safety of Navigation › N/A - No Subsystem › Pilot ladders and hoist/pilot transfer arrangements
Issued 25 July 2022 Resolved
Pilots provided a report indicating the pilots ladder was improperly rigged. The ladder was rigged to the winch drum brake but not a secure point on deck.
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Due 26 August 2022
Resolved 1 August 2022
Resolution: Documentation of training provided by company
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 June 2021 Resolved
SOLAS (14) II-2/10.4.1.1.1 FSS 2.1.3.1 The audible alarms shall be located so as to be audible throughout the protected space with all machinery operating, and the alarms should be distinguished from other audible alarms by adjustment of sound pressure or sound patterns. USCG inspector observed missing horn alarms from the fixed CO2 system in the cargo pump room.
Action required: 10 - Deficiency Rectified
Resolved 14 June 2021
Resolution: Witness satisfactory repair while on board
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 14 June 2021 Resolved
SOLAS(14)II-2/2.4.2.1 In lieu of paragraph 2.3 and in addition to complying with the specific provisins for integrity of bulkheads and decks of tankers, the minimum fire integrity of bulkheads and decks shall be as prescribed in tables 9.7 and 9.8. USCG inspector observed 08mm penetration through cargo pump room and engine room class A boundary - Evident by light from engine room.
Action required: 10 - Deficiency Rectified
Resolved 14 June 2021
Resolution: Observed sufficient repair of issue during exam.

Ownership record