← All vessels
GLOBAL PORTLAND
Tank Barge · Barge class · Built 2010s · USCG Southwest District (CGD-SW) · Other hulls named GLOBAL PORTLAND
GLOBAL PORTLAND is a 2011 tank barge. The Coast Guard has recorded 24 inspections since 2010, most recently in May 2026, along with 18 deficiencies.
Records from 2010 to 2026. Most recent: inspection, 5 May 2026.
- Built
- 2011
- Last inspected
- 5 May 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 18 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
1226765
1062700
Flag
UNITED STATES
—
Maury page id
psix-1062700
Inspections, by type
The 24 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Documentation record
Registered dimensions (L × B × D)182.4 ft × 46.0 ft × 15.0 ft
Registered tonnagegross 1,004 / net 306
ITC dimensions (L × B × D)182.4 ft × 46.0 ft × 15.0 ft
ITC tonnagegross 1,004 / net 306
BuilderTRINITY MARINE PRODUCTS INC PLANT 38 · MADISONVILLE, LA, UNITED STATES · built 2011
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portLOS ANGELES, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 18 December 2025 · expires 31 January 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1004 - Convention (Subpart B), Gross Ton
306 - Convention (Subpart B), Net Ton
306 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 24
5 May 2026
Bulk Liquid Transfer Monitor
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8367215
9 April 2025
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8071843
4 June 2024
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7900934
25 March 2024
Drydock Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7882308
27 February 2024
Internal Structural Exam · Drydock Extension
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7864421
21 March 2023
Internal Structural Exam · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7620301
20 January 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7624685
23 May 2022
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7457668
2 March 2021
Internal Structural Exam · Cargo Tank Internal · Administrative Inspection · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7148784
9 June 2020
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6923280
14 June 2019
Periodic Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6711145
14 February 2019
Drydock Exam · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6622763
8 May 2018
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6384422
25 April 2017
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6121383
15 March 2016
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5831688
23 February 2016
Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5816766
4 May 2015
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5117179
1 April 2015
Annual Inspection · DAPI Audit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5077763
26 March 2014
Hull Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4824443
14 March 2014
Internal Structural Exam · Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4815360
14 June 2012
Deficiency Check · In-Service Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4343933
14 May 2012
Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4311143
18 April 2012
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4256790
23 November 2010
MTSA Verification · Cargo Tank Internal · Construction Oversight · Drydock Exam · Internal Structural Exam · Initial Certification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3932453
Deficiency record · 18
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 9 April 2025
Resolved
PIPING SYSTEMS USED WHERE THE FLUID TEMPERATURE EXCEEDS 150 °F MUST BE SUITABLY INSULATED AS NECESSARY TO PRECLUDE INJURY TO PERSONNEL. MI DISCOVERED EXHAUST PIPE ON GENERATOR TO BE EXPOSED AND NOT PROTECTED.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 9 April 2025
Resolved
IN THE INSPECTION OF ELECTRIC EQUIPMENT AND INSTALLATIONS, THE RULES OF ABS FOR MATERIALS AND CONSTRUCTION ARE ACCEPTED AS STANDARD. MI DISCOVERED A JACKET WATER LEAK FROM A BAD GASKET IN THE PRIME MOVER OF THE BARGE'S GENERATOR.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 4 June 2024
Resolved
The tank overfill alarm required by paragraph (a) of this section must be identified with the legend “TANK OVERFILL ALARM” in black letters at least 50.8 millimeters (2 inches) high on a white background; Current markings are worn and unreadable. 46CFR39.2007(d)(2)
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 27 February 2024
Resolved
Tripped bracket and hull bottom longitudinal in port side #4 void. Make repairs during next drydock.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 21 March 2023
Resolved
Employers must ensure that they and their crewmembers
meet the requirements of this part (46 CFR 16). While
conducting a DAPI spot check, the most recent MIS report
could not be provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 June 2022
Resolved
Unmanned barge sidelight screens - proper color and shape. The sidelights of vessels shall be fitted with matt black inboard screens. Inspector found the sidelight screen paint of all four screens to be faded (i.e. no longer matt black).
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 June 2022
Resolved
A vessel towed alongside shall exhibit a sternlight. Inspector found the stern light to be inoperable.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 June 2022
Resolved
A vessel being pushed ahead shall exhibit at the forward end sidelights. Inspector found the starboard navigation light fixture in vicinity of the vessels office/galley space to be broken/fractured.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 June 2022
Resolved
A vessel being pushed ahead shall exhibit at the forward end sidelights. Inspector found the port navigation light fixture in vicinity of the vessels office/galley space to be improperly installed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 June 2022
Resolved
A vessel being pushed ahead shall exhibit at the forward end sidelights. Inspector found the port navigation light fixture in vicinity of the vessels machinery space to be broken/fractured.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 23 May 2022
Resolved
The total available supply of carbon dioxide shall be sufficient for the space rquiring the greatest amount (machinery space). Inspector found that the CO2 piping/wiring penetrating the bulkhead into the machinery space creates an opening that would allow CO2 to escape to atmosphere (i.e. not fill the space) when released.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 June 2020
Resolved
Each fixture , globe or lens must have a high strenght guard. Guard was broken.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 9 June 2020
Resolved
Maintenance of services neccessary for safety under normal and emergency conditions. Generator had a oil leak.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 25 April 2017
Resolved
Repaint red stripe on all vapor control lines.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 1 April 2015
Resolved
Provide service report for fixed CO2 fire fighting system prior to next cargo operations following next discharge.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 1 April 2015
Resolved
Provide visible overfill alarm that can be seen where cargo transfer is controlled & on deck area prior to next cargo load.
Deck/Cargo › Vapor Control Systems › Liquid Overfill Protection
Issued 14 May 2012
Resolved
Have external Alarm lights for Bergan Guard Level High level and Overfill Alarm System as presently wired to control panel examined by manufacturer rep. and found acceptable to the manufacturer. Condition found: Alarm lights were relocated to the top of the tankerman's shack, but electrical mods are not gas tight or secure. Vessel is limited to Grade D and lower cargoes until corrected.
Deck/Cargo › Vapor Control Systems › Liquid Overfill Protection
Issued 18 April 2012
Resolved
Provide audible and visual indicator for the overfill and high level alarm that can be seen and heard where cargo is controlled and on cargo deck area. 46 CFR 39-20-9(a)
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National