MAURY USCG vessel records
← All vessels

HELENA KOSAN

HELENA KOSAN is a 2007 tank ship. The Coast Guard has recorded 5 inspections since 2017, most recently in November 2021, along with 4 deficiencies — 1 with no resolution recorded —.

Records from 2017 to 2021. Most recent: inspection, 9 November 2021.

Built
2007
Last inspected
9 November 2021
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 9 November 2021
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 2 calendar years (2017–2021)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9342396
1063126
Flag
ISLE OF MAN
Maury page id
psix-1063126

Documentation record

Tonnage as PSIX records it13113 - Displacement, Metric Ton
8555 - Dead Weight, Metric Ton
7465 - Convention (Subpart B), Gross Ton
2239 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 5

9 November 2021 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7394345
5 November 2021 PSC B · Administrative Inspection · COC-GAS Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7341308
28 October 2021 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7341349
9 October 2017 ISPS II Exam · COC-GAS Renew · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6282689
8 October 2017 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6283662

Deficiency record · 4

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 November 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Unauthorized Type C deck tank was found on deck. 74 SOLAS (20) I/11
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 November 2021
Resolution: Received documentation from vessel and head of gas engineering division explaining the readings on the measurement panel. Master [name withheld] and Inspected tank showing that there was no product or residue inside the tank.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 5 November 2021 No resolution recorded
Hazardous ship stores - Cylinders must always be secured and when not in use, they must be stowed in a rack in an upright position. Multiple compressed gas cylinders were found around the deck not properly secured. 46 CFR 147.60(b)(1)
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 5 November 2021 Resolved
The company should establish procedures, plans, and instructions including checklists as appropriate for key shipboard operations. Plans and procedures need to be put in place regarding the unauthorized type C deck tank. 74 SOLAS (20) IX/3.1- ISM Code 7
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2021
Resolved 9 November 2021
Resolution: Company has procedures and manuals in place, and is releasing them to the vessel. Tank has been fully disconnected and requires no further testing or maintenance until brought into proper service.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 5 November 2021 Resolved
Emergency shutdown valves in liquid piping should fully close under all service conditions within 30 seconds of activation. The first test of the Port manifold liquid line closure ESD took 60 seconds to close. After adjusting the settings the ESD was brought into compliance. 74 SOLAS (20) IX/3.1 - IGC (93) 5.6.4
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 November 2021
Resolution: Vessel crew was able to adjust closing time before inspection team departed.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.