AAL GIBRALTAR
AAL GIBRALTAR is a 2010 public freight. The Coast Guard has recorded 19 inspections since 2010, most recently in April 2025, along with 15 deficiencies and 3 operational controls.
Records from 2010 to 2025. Most recent: inspection, 2 April 2025.
- Built
- 2010
- Last inspected
- 2 April 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 15 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9393565 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
5BXJ2
1064752
Flag
CYPRUS
—
Maury page id
psix-1064752
Inspections, by type
…with no type recorded2
Years with a record
11 calendar years (2010–2025)
The 19 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it35111 - Displacement, Metric Ton
25732 - Dead Weight, Metric Ton
19128 - Convention (Subpart B), Gross Ton
9736 - Convention (Subpart B), Net Ton
25732 - Dead Weight, Metric Ton
19128 - Convention (Subpart B), Gross Ton
9736 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 19
2 April 2025
Deficiency Check · PSC B
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8099215
10 June 2024
PSC B
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7928891
24 April 2024
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7900599
9 June 2023
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7702998
30 May 2023
PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7696230
24 May 2023
Explosive Handling Operation-Commercial
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7697073
1 July 2022
PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7490574
13 June 2022
Deficiency Check · PSC A
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7476104
16 July 2019
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6749132
13 July 2018
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6457084
28 October 2016
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6027795
2 September 2016
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5990458
29 April 2016
Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 5865596
28 April 2016
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 5864540
6 October 2015
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5733248
5 February 2012
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4238738
6 July 2011
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4071771
16 January 2011
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3927673
15 November 2010
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3891794
Deficiency record · 15
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 June 2024
Resolved
Means shall be provided to control leaks of flammable liquids. #1 cylinder fuel return line on main diesel engine leaking.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 June 2024
Resolved
Means shall be provided to control leak of flammable liquids. Steering gear is leaking hydraulic fluid.
14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management System (BMWS)
Issued 10 June 2024
Resolved
Each ballast water management system manufactured under Coast Guard approval must have a nameplate which is securely fastened to the BWMS and plainly marked by the manufacturer with required information. BWMS missing required placard.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 13 June 2022
Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additionally requirements which may be established by the company. In meeting these requirements the company should ensure that: inspections are held at appropriate intervals; any non-conformity is reported with its possible cause, if known; records of these activities are maintained.
As noted in deficiencies 02-08, there is objective evidence that the ship is not being maintained or operated as required in relation to fire-fighting and maintenance.
An external ISM audit is required with a focus on fire-fighting, maintenance in engine room, and control of flammable liquids.
74 SOLAS 14 IX/ 3.1
ISM Code 10.2.1
ISM Code 10.2.2
ISM Code 10.2.4
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 13 June 2022
Resolved
Means shall be provided to control leaks of flammable liquids.
Numerous oil leaks were discovered in the engine room with rags and plastic containers used as temporary collections. L/O leak for cooler for MDE w/ two collection pans totaling aprox 1 gal of L/O. #2 GEN had plastic pan and rags collecting leaking oil. Aprox 1/2 gal of oil collected. Two F/O supply pumps found leaking w/ steady flow rate being collected in temporary pans. Two replacement pumps received at last at last port and are currently being replaced. F/O pump in purifier room had steady leak being collected in plastic bottle.
74 SOLAS 14 II-2/ 4.1.1
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 13 June 2022
Resolved
he maintenance plan shall include at least the following fire protection systems and fire-fighting systems and appliances, where installed: automatic sprinker, fire detection and fire alarm systems.
Port State Control Officer requested to review maintenance and log book records for water mist system. Crew could not produce requested records. Water mist system procedures are not included in the maintenance plan, thus no guidance currently exists on board
74 SOLAS 14 II-2/14.2.2.3.4
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 13 June 2022
Resolved
Oil fuel pipes, which, if damaged, would allow oil to escape from a storage, settling or daily service tank having a capacity of 500l and above situated above the double bottom, shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside the space concerned in the event of a fire occurring in the space in which such tanks are situated.
Air receiver for engine room quick closing valves had an uncontrolled leak and was unable to maintain pressure. Crew changed gasket at source of leak, and condition persisted.
74 SOLAS 14 II-2/4.2.2.3.4
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 13 June 2022
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use.
Water mist control panel break was found off w/ no power supplied to the unit. Crew turned it on.
74 SOLAS 14 II-2/14.2.1.2
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 June 2022
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship or persons on board.
Constant leak of S/W from #1 cylinder on MDE. The uncontrolled leak (comparable to garden hose pressure) was spraying down MDE, contacting numerous electrical panels
74 SOLAS 14 I/ 11(a)
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 13 June 2022
Resolved
Except as specified in paragraph 3 of this regulation, any ship of 10,000 gross tonnage and above shall be fitted with oil filtering equipment complying with paragraph 7 of this regulation.
When crew was conducting in port operational testing of OWS, water began leaking from OWS connection points throught
MARPOL CONS. ED 2017 I/ 14.2
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 June 2022
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board
Valve for ballast water stripping pump was leaking at the stem at a steady rate and was being redirected to the bilge by gasket material
74 SOLAS 14 1/ 11(a)
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 16 July 2019
Resolved
To assist in casualty investigations, ships shall be fitted with a voyage data recorder. PSCO observed a microphone error on the VDR display.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 13 July 2018
Resolved
2 Heat detectors one above the #1 Generator and one in the Purifier Room were found to be inoperable.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 13 July 2018
Resolved
Found one smoke detector inoperable.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 13 July 2018
Resolved
Valve for Water Mist System was found in a closed position.