NEUTRON SOUND is a 2007 tank ship. The Coast Guard has recorded 11 inspections since 2019, most recently in April 2024, along with 1 deficiency and 2 operational controls.
Records from 2019 to 2024. Most recent: inspection, 25 April 2024.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it49997 - Dead Weight, Ton 60014 - Displacement, Ton 30002 - Convention (Subpart B), Gross Ton 13075 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 11
25 April 2024COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7901060
10 July 2022Bulk Liquid Transfer Monitor
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7502550
9 July 2022Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7501583
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 30 May 2019Resolved
12107, 10C
The simultaneous use of the minimum required jets of water shall be possible on deck over the full length of the ship. Fire monitors unable to cover the full length of the deck.
74SOLAS(09) II-2/10.4.1.1.2
FSS Code 14.2.1.3
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 30 May 2019
Resolved 30 May 2019
Resolution: The crew was able to attain adequate pressure at the fire monitors.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.