← All vessels
BLACK DAGGER
Passenger (Inspected) · Passenger Ship class · Built 2010s · USCG Southeast District (CGD-SE) · Other hulls named BLACK DAGGER
BLACK DAGGER is a 2010 passenger vessel (inspected). The Coast Guard has recorded 23 inspections since 2011, most recently in February 2026, along with 27 deficiencies and 1 operational control.
Records from 2011 to 2026. Most recent: inspection, 24 February 2026.
- Built
- 2010
- Last inspected
- 24 February 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 27 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
1227324
WDM7998
1065570
Flag
UNITED STATES
367453540
Maury page id
psix-1065570
Inspections, by type
…with no type recorded1
Years with a record
14 calendar years (2011–2026)
The 23 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)46.0 ft × 16.0 ft × 6.0 ft
Registered tonnagegross 29 / net 29
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderEVANS BOAT REPAIR INC · CRISFIELD, MD, UNITED STATES · built 2010
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portHILTON HEAD ISLAND, SC
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 6 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it29 - Simplified, Gross Ton
29 - Dead Weight, Gross Ton
29 - Simplified, Net Ton
29 - Dead Weight, Gross Ton
29 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDM7998MMSI 367453540 · active · compulsorily equipped · granted 12 February 2022, expires 12 February 2032
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 23
24 February 2026
Annual Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8297537
18 February 2025
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8081019
6 November 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8032108
5 February 2024
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7860530
26 January 2023
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7630486
13 December 2022
Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7607915
28 February 2022
Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7393934
7 December 2020
Construction Oversight · Drydock Exam · Annual Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7110010
7 May 2020
Internal Structural Exam · DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6928404
2 January 2020
Construction Oversight · Administrative Inspection · Damage Survey · Drydock Extension
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6881811
29 April 2019
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6673352
18 October 2018
Plan Review "T" Boat · Construction Oversight
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6564255
21 March 2018
Annual Inspection · DAPI Audit
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6376897
22 February 2018
Deficiency Check · Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6360238
1 March 2017
COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6092495
5 January 2017
Plan Review (Other than "T")
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6068842
13 September 2016
Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5998977
13 January 2016
Administrative Inspection · Deficiency Check · Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5798336
21 September 2015
Annual Inspection · Administrative Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5722691
14 October 2014
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5004663
7 March 2014
Administrative Inspection · Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4811931
5 July 2012
COI Inspection · Administrative Inspection · Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4368595
12 September 2011
Annual Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4142865
Deficiency record · 27
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 February 2026
Resolved
When the flexible section is a nonconductor of electricity, the metallic sections of the fill pipe separated thereby must be joined by a conductor for protection against generation of a static charge when filling with fuel.
Bonding strap was broken on Starboard Fuel Tank.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 24 February 2026
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury.
Starboard Transmission cable badly corroded and could fail at any time.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 13 December 2022
Resolved
A section of delaminated plywood measuring approx. 4' x 8' and a rotted deck support measuring 3' in length was found in the third void in the forward section. Both areas to replaced to original construction.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 December 2022
Resolved
Bilge pump in fourth void space was found not secured to the mount. Mount bilge pump and show proper operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 May 2020
Resolved
Show proper operation of three hand bilge pumps to show compliance with 10 GPM requirement.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 May 2020
Resolved
Remove water from bilges and clean debris from all bilge spaces.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 7 May 2020
Resolved
Place in service two additional USCG approved VDS' to meet carriage requirement.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 May 2020
Resolved
Renew SOLAS A retroflective tape to identified Type I PFDs.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 7 May 2020
Resolved
Provide maintenance to all watertight deck hatches and show proper operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 April 2019
Resolved
Show proof of replacement of overheat sensor.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 April 2019
Resolved
Place in service one 10: B/C portable fire extinguisher.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 29 April 2019
Resolved
Provide maintenance and show operation of all watertight hatches.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 29 April 2019
Resolved
Remove excessive water and debris from bilges.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 April 2019
Resolved
Provide replacement Solas A tape to identified lifejackets.
Construction/Loadline › Structures › Deck Plating
Issued 22 February 2018
Resolved
Provide plans to repair damaged areas on the port side deck beams and plywood.
Documentation › Logs/Records › Drug Test Records
Issued 13 September 2016
Resolved
Vessel did not have proof of enrollement for drug consortium onboard. Provide proof of enrollement by 13OCT2016.
Operations/Management › Drills/Instruction › Safety Orientation
Issued 13 September 2016
Resolved
Vessel did not have a lifejacket donning instructional placard posted or onboard. Post lifejacket donning instructional placard by 13OCT2016.
Communications › Audible Communications › Horn/Whistle
Issued 13 September 2016
Resolved
Vessel's horn did not work. Repair vessel horn by 13OCT2016. (COLREG 33)
Fire Fighting › Remote Fuel Shutoff › General
Issued 21 September 2015
Resolved
Mark emergency fuel shutdown with 1 inch letters "FUEL SHUTOFF" & on/off direction arrows on valve.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 21 September 2015
Resolved
Renew expired Radio Telephony Certificate.
Sail Rigging › Stays/Shrouds › Wires
Issued 10 March 2014
Resolved
Triple wire clamp fore stay and shrouds. 46CFR176.610
Sail Rigging › Deck Hardware › Shackles
Issued 10 March 2014
Resolved
Mouse shackle pins for fore stay and shrouds. 46CFR176.610
Construction/Loadline › Hull › Hull Plating
Issued 10 March 2014
Resolved
Properly seal FRP hull in vicinity of bow thruster.
Sail Rigging › Mast Step › Base
Issued 10 March 2014
Resolved
Provide sufficient size washers on aft portion of mast step. 46CFR176.610
Documentation › Certificates/Documents › Certificate of Inspection
Issued 5 July 2012
Resolved
Vessel must complete a satisfactory hull exam before carrying passengers. 46 CFR 176.600
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 5 July 2012
Resolved
Replace broken masthead light in compliance with the applicable sections of the Inland Navigation Rules as required by 46 CFR 183.420 prior to night operations.
Engineering › Bilge Water Management System › Pump
Issued 12 September 2011
Resolved
Vessel did not have portable hand bilge pump onboard