MAURY USCG vessel records
← All vessels

BLACK DAGGER

BLACK DAGGER is a 2010 passenger vessel (inspected). The Coast Guard has recorded 18 inspections since 2016, most recently in February 2026, along with 18 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 24 February 2026.

Built
2010
Last inspected
24 February 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDM7998
1065570
Flag
UNITED STATES
Maury page id
psix-1065570

Inspections, by type

Years with a record 10 calendar years (2016–2026)
The 18 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Registered dimensions (L × B × D)46.0 ft × 16.0 ft × 6.0 ft
Registered tonnagegross 29 / net 29
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderEVANS BOAT REPAIR INC · CRISFIELD, MD, UNITED STATES · built 2010
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portHILTON HEAD ISLAND, SC
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 6 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it29 - Simplified, Gross Ton
29 - Dead Weight, Gross Ton
29 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 18

24 February 2026 Annual Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8297537
18 February 2025 Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8081019
6 November 2024 Internal Structural Exam · Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8032108
5 February 2024 Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7860530
26 January 2023 Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7630486
13 December 2022 Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7607915
28 February 2022 Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7393934
7 December 2020 Construction Oversight · Drydock Exam · Annual Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7110010
7 May 2020 Internal Structural Exam · DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6928404
2 January 2020 Construction Oversight · Administrative Inspection · Damage Survey · Drydock Extension
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6881811
29 April 2019 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6673352
18 October 2018 Plan Review "T" Boat · Construction Oversight
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6564255
21 March 2018 Annual Inspection · DAPI Audit
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6376897
22 February 2018 Deficiency Check · Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6360238
1 March 2017 COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6092495
5 January 2017 Plan Review (Other than "T")
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6068842
13 September 2016 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5998977
13 January 2016 Administrative Inspection · Deficiency Check · Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5798336

Deficiency record · 18

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 February 2026 Resolved
When the flexible section is a nonconductor of electricity, the metallic sections of the fill pipe separated thereby must be joined by a conductor for protection against generation of a static charge when filling with fuel. Bonding strap was broken on Starboard Fuel Tank.
Condition: Improper/Lack of Maintenance
Action required: 703 - Prior to bunkering operations
Resolved 6 March 2026
Resolution: Bonding strap re-attached to filler neck.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 24 February 2026 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Starboard Transmission cable badly corroded and could fail at any time.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 March 2026
Resolution: Cable was replaced with new one.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 13 December 2022 Resolved
A section of delaminated plywood measuring approx. 4' x 8' and a rotted deck support measuring 3' in length was found in the third void in the forward section. Both areas to replaced to original construction.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 January 2023
Resolution: Repairs were made to the affected areas.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 December 2022 Resolved
Bilge pump in fourth void space was found not secured to the mount. Mount bilge pump and show proper operation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 January 2023
Resolved 10 January 2023
Resolution: Bilge pump was mounted and will be tested at the next annual inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 May 2020 Resolved
Show proper operation of three hand bilge pumps to show compliance with 10 GPM requirement.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 June 2020
Resolution: Observed satisfactory operation of four hand bilge pumps.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 May 2020 Resolved
Remove water from bilges and clean debris from all bilge spaces.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 June 2020
Resolution: Water and debris was removed from the bilges.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 7 May 2020 Resolved
Place in service two additional USCG approved VDS' to meet carriage requirement.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 June 2020
Resolution: Two additional flares were placed in service.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 May 2020 Resolved
Renew SOLAS A retroflective tape to identified Type I PFDs.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 June 2020
Resolution: All lifejackets were replaced or new Solas A tape was placed in service.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 7 May 2020 Resolved
Provide maintenance to all watertight deck hatches and show proper operation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 June 2020
Resolution: Vessel rep showed proper operation of deck hatches.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 April 2019 Resolved
Show proof of replacement of overheat sensor.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2019
Resolved 31 May 2019
Resolution: Engine overheat sensor was replaced by certified technician.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 April 2019 Resolved
Place in service one 10: B/C portable fire extinguisher.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 April 2019
Resolution: A new 10: B/C was placed in service.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 29 April 2019 Resolved
Provide maintenance and show operation of all watertight hatches.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 April 2019
Resolution: All hatches were maintained and operated.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 29 April 2019 Resolved
Remove excessive water and debris from bilges.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 May 2019
Resolution: Debris and water was removed from the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 April 2019 Resolved
Provide replacement Solas A tape to identified lifejackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 May 2019
Resolution: SOLAS tape was applied to identified lifejackets.
Construction/Loadline › Structures › Deck Plating
Issued 22 February 2018 Resolved
Provide plans to repair damaged areas on the port side deck beams and plywood.
Action required: 705 - Other - as specified
Due 1 April 2018
Resolved 5 March 2018
Resolution: Received plan to provide temporary repairs to the deck.
Documentation › Logs/Records › Drug Test Records
Issued 13 September 2016 Resolved
Vessel did not have proof of enrollement for drug consortium onboard. Provide proof of enrollement by 13OCT2016.
Action required: 705 - Other - as specified
Due 13 October 2016
Resolved 27 September 2016
Operations/Management › Drills/Instruction › Safety Orientation
Issued 13 September 2016 Resolved
Vessel did not have a lifejacket donning instructional placard posted or onboard. Post lifejacket donning instructional placard by 13OCT2016.
Action required: 705 - Other - as specified
Due 13 October 2016
Resolved 27 September 2016
Communications › Audible Communications › Horn/Whistle
Issued 13 September 2016 Resolved
Vessel's horn did not work. Repair vessel horn by 13OCT2016. (COLREG 33)
Action required: 705 - Other - as specified
Due 13 October 2016
Resolved 27 September 2016

Ownership record