Records from 1984 to 1994. Most recent: inspection, 8 July 1994.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 23
8 July 1994
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 72810
7 July 1994
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2176
5 July 1994
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1178060
15 June 1994
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 861393
22 February 1994
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1165191
21 June 1993
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1151589
18 May 1993
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1138972
11 December 1992
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1142094
6 April 1992
Re-Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 950878
3 May 1991
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1244878
28 March 1991
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 932260
28 March 1990
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1225979
16 November 1989
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1240712
5 September 1989
Drydock Extension
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1348067
19 April 1989
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1352899
8 April 1988
Re-Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1034141
3 April 1987
Deficiency Check · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1014801
10 November 1986
Hull Examination · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1326860
16 April 1986
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1307178
8 May 1985
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 983484
22 April 1985
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1292220
11 April 1984
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 972951
9 January 1984
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1280499
Electrical
Issued 3 May 1991
Resolved
INSTALL COVERS TO EACH BATTERY BOX INSTALLATION IAW 46 CFR 183.05-20(a)._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 May 1991
Resolved 3 May 1991
Fire Fighting
Issued 3 May 1991
Resolved
INSTALL PROPER FIRE-EXTINGUSHER BRACKET FOR MARINE USE TO FIRE EXTINGUISHERIN FWD COMPARTMENT._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 May 1991
Resolved 3 May 1991
Engineering
Issued 3 May 1991
Resolved
REMOVE EXISTING NON-U.L.-APPROVED FOR MARINE USE FUEL FILTERS AND INSTALL SUITABLE MARINE TYPE STRAINER/FILTER IAW 46 CFR 182.20-40(b)(5)._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 May 1991
Resolved 3 May 1991
Unknown
Issued 8 April 1988
Resolved
PROVIDE DOUBLE HOSE CLAMPS FOR ELECTRIC PUMP LINES(WASHDOWN AND LIVEWELLS).
Condition: Unknown
Due 8 April 1988
Resolved 8 April 1988
Unknown
Issued 8 April 1988
Resolved
PROVIDE GREATER THAN 20 AMP CIRCUIT BREAKER PROTECTION FOR REEL RECEPTA- CLES.
Condition: Unknown
Due 8 April 1988
Resolved 8 April 1988
Unknown
Issued 8 April 1988
Resolved
PROVE PROPER OPS OF BOW LIGHT.
Condition: Unknown
Due 8 April 1988
Resolved 8 April 1988
Unknown
Issued 8 April 1988
Resolved
PROVE PROPER OPS OF CABIN LIGHT.
Condition: Unknown
Due 8 April 1988
Resolved 8 April 1988
Unknown
Issued 8 April 1988
Resolved
PROVE PROPER OPS OF PORTLIGHT DOGS.
Condition: Unknown
Due 8 April 1988
Resolved 8 April 1988
Fire Fighting
Issued 3 April 1987
Resolved
PROVIDE AUTOMATIC ENGINE SHUT-DOWN DEVICE TO 15 LB 1301 HALON BOTTLE IN ENGINE SPACE OR REMOVE SAME AND PROVIDE AN ADDITIONAL B-II TYPE PORTABLE FIRE EXTINGUISHER.
Condition: Unknown
Due 3 April 1987
Resolved 3 April 1987
Engineering
Issued 3 April 1987
Resolved
PROVIDE ACCESS PLATES WITH COVERS ON COCKPIT DECK TO BOTH REMOTE FUEL SHUT OF VALVES.
Condition: Unknown
Due 3 April 1987
Resolved 3 April 1987
Documentation
Issued 3 April 1987
Resolved
PROVIDE VALID FCC SAFETY RADIOTELEPHONY CERTIFICATE.
Condition: Unknown
Due 3 April 1987
Resolved 3 April 1987
Accommodation/Occupational Safety
Issued 22 April 1985
Resolved
INSTALL DECK RAILS IN ACCORDANCE WITH 46CFR 177.35 THIS REQIREMENT MUST BE COMPLETED ON OR BEFORE 1JUN85.
Condition: Unknown
Due 22 April 1985
Resolved 22 April 1985