NO. 17
NO. 17 is a 2010 tank barge. The Coast Guard has recorded 33 inspections since 2010, most recently in December 2025, along with 39 deficiencies and 1 casualty investigation in 2021.
Records from 2010 to 2025. Most recent: inspection, 29 December 2025.
- Built
- 2010
- Last inspected
- 29 December 2025
- Documentation
- Valid · documentation file of 10 August 2026
- Deficiencies
- 39 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2021
Identity
1228239
1066502
Flag
UNITED STATES
Maury page id
psix-1066502
Inspections, by type
…with no type recorded2
Years with a record
16 calendar years (2010–2025)
The 33 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Documentation record
Registered dimensions (L × B × D)132.0 ft × 30.0 ft × 9.0 ft
Registered tonnagegross 299 / net 299
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMETAL TRADES INC · YONGES ISLAND, SC, UNITED STATES · built 2010
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portNORFOLK, VA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 4 August 2025 · expires 30 September 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it299 - Simplified, Gross Ton
299 - Simplified, Net Ton
299 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.
Inspection history · 33
29 December 2025
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8286749
15 September 2025
COI Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8234880
14 January 2025
COI Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8074757
20 March 2024
Deficiency Check · Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7881873
14 February 2023
Annual Inspection · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7636806
2 February 2023
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7630910
6 December 2022
Administrative Inspection · Deadweight Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7604815
29 November 2022
Administrative Inspection · Load Line/Change of Employment
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7601044
13 June 2022
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7476719
19 December 2021
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7370654
18 December 2021
Damage Survey · COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7370154
19 August 2020
COI Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7037246
28 July 2020
Administrative Inspection · Examination of Repairs
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7018551
20 February 2020
Drydock Exam · Administrative Inspection · Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6914615
25 September 2019
MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6820397
26 March 2019
Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6649231
18 March 2019
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6644572
10 January 2019
Periodic Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6609669
13 February 2018
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6354278
20 November 2017
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6309790
24 October 2016
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6046214
17 October 2016
Annual Inspection · MTSA Verification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6023920
30 October 2015
MTSA Verification · COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5754380
20 October 2015
Internal Structural Exam · Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5746667
9 September 2014
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4979635
5 September 2014
MTSA Verification · Periodic Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4967394
8 May 2014
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4853340
23 September 2013
Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4721444
30 November 2012
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4495203
25 August 2012
Administrative Inspection · Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4421661
24 August 2012
Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4504316
7 October 2011
MTSA Verification · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4165296
10 June 2010
Internal Structural Exam · Construction Oversight · Initial Certification · Drydock Exam · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3762662
Deficiency record · 39
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 29 December 2025
Resolved
33 CFR 155.1060(a)(3) : Shore-based spill management team tabletop exercises, which must be conducted annually. In a triennial period, at least one of these exercises must include a worst case discharge scenario. Vsl unable to produce documentation of tabletop exercise.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 29 December 2025
Resolved
33 CFR 155.1060(b): Annually, at least one of the exercises listed in § 155.1060(a) (2) and (4) must be unannounced. An unannounced exercise is one in which the personnel participating in the exercise have not been advised in advance of the exact date, time, and scenario of the exercise. Vsl unable to produce documentation of
unannounced response plan exercise.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 29 December 2025
Resolved
33 CFR 155.1060(a)(4): Oil spill removal organization equipment deployment
exercises, which must be conducted annually. Vsl unable
to produce documentation of equipment deployment
exercises.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 29 December 2025
Resolved
33 CFR 155.1060(a)(1): Qualified individual notification exercises, which must be conducted quarterly. Vsl unable to produce documentation of quarterly QI notifications.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 29 December 2025
Resolved
33 CFR 155.1060(a)(2):Emergency procedures exercises, which must be conducted quarterly. Vsl unable to produce documentation of quarterly emergency procedure exercises.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 29 December 2025
Resolved
33 CFR 155.1055(b): A vessel owner or operator shall ensure the maintenance of records sufficient to document this training and make them available for inspection upon request by the Coast Guard. Records must be maintained for 3 years following completion of training. 3 years of response plan training records not available to USCG upon request.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 December 2025
Resolved
33 CFR 104.230(b)(1): The VSO must ensure that at least one security drill is conducted at least every 3 months. Vsl unable to produce documentation of required security drills from the past 2 years.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 December 2025
Resolved
46 CFR 58.10-5(a) : All installations must be of marine type engines suitable for the intended service, designed and constructed in conformance with the requirements of this subchapter. Exhaust manifold on cargo pump engine was heavily corroded.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 29 December 2025
Resolved
33 CFR 156.170(c)(2): Each transfer system relief valve must open at or below the pressure at which it is set to open. Cargo pump relief valve did not have record of annual testing.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 29 December 2025
Resolved
33 CFR 156.170(c)(3): Each pressure gauge must show pressure within 10 percent of the actual pressure. Transfer system pressure gauge did not have record of annual testing.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 29 December 2025
Resolved
33 CFR 155.400(e): Each hose must be marked with one of the following: The name of each product for which the hose may be used; or “OIL SERVICE”. Cargo transfer hoses were not marked with service type.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 29 December 2025
Resolved
33 CFR 155.400(f): Each hose also must be marked with the following, except that the information required by paragraphs (f)(2) and (3) of this section need not be marked on the hose if it is recorded in the hose records of the vessel or facility, and the hose is marked to identify it with that information: (1) Maximum allowable working pressure; (2) Date of manufacture; and (3) Date of the latest test required by 33 CFR 156.170. Transfer hoses were not marked IAW regulations.
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 29 December 2025
Resolved
33 CFR 104.120(b): Each owner or operator of an unmanned vessel subject to this part must maintain the documentation described in paragraphs (a)(1), (2), or (3) of this section. The letter required by each of those paragraphs must be carried on board the vessel. No VSP approval letter was on board vessel.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 29 December 2025
Resolved
Each transfer pipe system must not leak under static
liquid pressure at least 1 1 2 times the maximum
allowable working pressure. Cargo piping system did not
have record of annual testing at 1.5 x MAWP. 33 CFR 156.170(4)
Prior to cargo operations.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 29 December 2025
Resolved
Not burst, bulge, leak, or abnormally distort under
static liquid pressure at least 11 2 times the maximum
allowable working pressure. Transfer hoses did not have
record of annual testing at 1.5 x MAWP. 33 CFR 156.170(1)(iii)
Prior to cargo operations.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 20 March 2024
Resolved
Vent outlets from all tanks which may emit flammable or combustible vapors, such as bilge slop tanks and contaminated drain tanks, must be fitted with a single screen of corrosion-resistant wire of at least 30 by 30 mesh, or two screens of at least 20 by 20 mesh spaced not less than one-half inch (13mm) nor more than 1 1/2 inches (38mm) apart. The clear area through the mesh must not be less than the internal unobstructed area of the required pipe.
5 out of the 6 cargo tanks goose neck vents had rips/holes in the mesh of the flame screen.
Vessel is require to replace the flame screen mesh to the satisfaction of the attending MI.
46 CFR 56.50-85(a)(8)
16C
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 20 March 2024
Resolved
Valves for drawing fuel or draining water from fuel are not permitted in fuel oil systems except that a single valve may be permitted in the case of diesel driven machinery if suitably located within the machinery space away from any potential source of ignition. Such a valve shall be fitted with a cap or a plug to prevent leakage.
Vessels fuel oil filter on the prime mover had a plastic
collection bowl and plastic valve.
Vessel is required to replace or fit the prime mover with the appropriate items for the fuel filter to the satisfaction of the attending MI.
46 CFR 56.50-60(f)
16C
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 March 2024
Resolved
Each cable installation must meet—
(1) Sections 6, of IEEE 45.8–2016 (incorporated by reference; see § 110.10–1 of this subchapter); or
(2) Cables manufactured to IEC 60092–353:2016 must be installed in accordance with IEC 60092–352:2005 (both incorporated by reference; see § 110.10–1 of this subchapter), including clause 8.
Vessels battery cables on the prime mover were cracking/brittle wiring insulation.
Vessel is required to replace the defective battery cables with approved battery cables to the satisfaction of the attending MI.
46 CFR 111.60-5(a)
16C
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 18 December 2021
Resolved
Your vessel must undergo an annual inspection within 3 months before or after each anniversary date, except as specified in paragraph (b) of this section. Vessel can provide no evidence that it underwent its first annual inspection as required. Vessel is prohibited from operating until Coast Guard Annual Inspection or COI Renewal Inspection is completed.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 18 December 2021
Resolved
Any tank vessel which is equipped with an internal combustion engine driven cargo pump on the weather deck shall be provided with a minimum of one remote manual shutdown station, conspicuously marked, and located at the midpoint of such vessel, or 100 feet from the engine, whichever is the more practical. The remote quick acting manual shutdown shall be installed on the engine so as to provide a quick and effective means of stopping the engine. Neither mechanical nor electric remote stops functioned at time of inspection. Prove proper operation of emergency stops to satisfaction of attending Marine Inspector
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 18 December 2021
Resolved
The cargo handling equipment shall be maintained by the tank vessel's personnel in accordance with the regulations in this subchapter, including the following: (b) Cargo pump relief valves shall be tested at least once each year to determine that they function satisfactorily at the pressure at which they are set to open. (c) Cargo pump pressure gage shall be tested at least once a year for accuracy. (d) The cargo discharge piping of all tank vessels shall be tested at least once each year for tightness, at the maximum working pressure No evidence provided of cargo piping, cargo pump relief valve, or cargo pump gauge being tested annually. Complete cargo equipment testing to the satisfaction of the attending Marine Inspector.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 18 December 2021
Resolved
The operator of a vessel with a capacity of 250 or more barrels of oil, hazardous material, or liquefied gas as regulated in Table 4 of 46 CFR part 154 shall provide transfer procedures that meet the requirements of this part and part 156 of this chapter for transferring - (a) To or from the vessel; and (b) From tank to tank within the vessel. No transfer procedures found on board vessel. Provide satisfactory transfer procedures to attending Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 December 2021
Resolved
All portable and semiportable extinguishers on board tank vessels shall be of an approved type. Both 40:B-C portable extinguishers require annual servicing to be of an approved type and missed annual servicing dates for 2021. Demonstrate portable extinguishers on board are of an approved type to the attending marine inspector.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 18 December 2021
Resolved
A tank vessel with a capacity of 250 or more barrels that is carrying oil or hazardous material as cargo must have -A means of draining or removing discharged oil or hazardous material from each container or enclosed deck area without discharging the oil or hazardous material into the water. Vessel is missing 4 plugs for containment. Prove to attending Marine Inspector that all containment drains have plugs.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 December 2021
Resolved
(a) Electric installations on vessels must ensure: (1) Maintenance of services necessary for safety under normal and emergency conditions. (2) Protection of passengers, crew, other persons, and the vessel from electrical hazards. (3) Maintenance of system integrity through compliance with the applicable system requirements (IEEE, NEC, IEC, etc.) to which plan review has been approved. Marine Inspector deemed wiring at cargo pump to be a significant electrical hazard to vessel personnel. Prove to attending Marine Inspector safe operation of electrical equipment and that system integrity is maintained.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil and oily mixtures from machinery spaces
Issued 18 December 2021
Resolved
A ship, except a ship of less than 26 feet in length, must have a placard of at least 5 by 8 inches, made of durable material fixed in a conspicuous place in each machinery space, or at the bilge and ballast pump control station, stating the oil of discharge is prohibited.
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 19 August 2020
Resolved
A coaming, at least 4 inches high but not more than 8 inches high, enclosing the immediate area of the cargo hatches, loading manifolds, and transfer connections, that has a capacity, in all conditions of vessel list and trim to be encountered during the loading operation, of at least one-half barrel per hatch, manifold, and connection within the enclosed area.
Missing 3 plugs in coaming
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 19 August 2020
Resolved
Any tank vessel which is equipped with an internal combustion engine driven cargo pump on the weather deck shall be provided with a minimum of one remote manual shutdown station, conspicuously marked, and located at the midpoint of such vessel, or 100 feet from the engine, whichever is the more practical. The remote quick acting manual shutdown shall be installed on the engine so as to provide a quick and effective means of stopping the engine.
shut down is not conspicuously marked.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 19 August 2020
Resolved
Shutoff valves. Shutoff valves shall be installed in the fuel supply lines, one as close to each tank as practicable, and one as close to each fuel pump as practicable. Valves shall be accessible at all times.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 19 August 2020
Resolved
Vent outlets from all tanks which may emit flammable or combustible vapors, such as bilge slop tanks and contaminated drain tanks, must be fitted with a single screen of corrosion-resistant wire of at least 30 by 30 mesh, or two screens of at least 20 by 20 mesh spaced not less than one-half inch (13mm) nor more than 11/2 inches (38mm) apart. The clear area through the mesh must not be less than the internal unobstructed area of the required pipe.
Vent flame screen was broken on fuel tank.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 19 August 2020
Resolved
This section of the plan must contain information to assist the master in initiating action by the coastal State, local government, or other involved parties. This information must include guidance to assist the master with organizing a response to the incident, should a response not be organized by the shore authorities. Detailed information for specific areas may be included as appendices to the plan. See 33 CFR 151.26(b)(2) (Preamble) regarding a ship owner's responsibility to comply with individual state requirements for oil spill response.
Per their Plan required notifcation to be located on board and was not present.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 18 March 2019
Resolved
ISE not completed as required (31 Oct 2018). Make barge available for ISE upon arrival to Sector Hampton Roads zone. Cargo operations are not to be conducted until ISE is conducted and approved by Sector Hampton Roads USCG Marine Inspector.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 10 January 2019
Resolved
Any Tank vessel which is equipped with an internal combustion engine driven cargo pump on the weather deck shall be provided with a remote manual fuel shutdown. Manual shutdown failed while testing. repair/replace and prove proper operation.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 18 October 2016
Resolved
Unable to verify if the cargo pump prime mover fuel hoses meet SAE J1942. Provide documentation that the hoses meet the standard or install hoses that meet SAE J1942, not to exceed 30 inches. In addition, hose fittings must comply with SAE J1475 and must be installed following the manufacturer's recommended practice.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Relief Valve
Issued 5 September 2014
Resolved
Cargo pump relief valve had not been annually tested. Demonstrate proper operation of relief valve.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 5 September 2014
Resolved
Cargo system piping pressure gauge had not been tested anually. Demonstrate accuracy of pressure gauge.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 23 September 2013
Resolved
Provide MAWP rating of all cargo pipelines.
Construction/Loadline › Hull › Longitudinal Frame
Issued 23 September 2013
Resolved
Repair damaged longitudinal weld in port side void #2, bay #2, #2 longitudinal from the bottom.
Construction/Loadline › Hull › Weld
Issued 23 September 2013
Resolved
Prior to loading cargo, repair pin hole leak in port side cargo tank #2, void #2, bay #2, to the satisfaction of the attending Marine Inspector.
Casualty record · 1
19 December 2021Routine · role: Involved in a Marine Casualty · activity 7370654
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.