MAURY USCG vessel records
← All vessels

SEAS THE DAY

SEAS THE DAY is a 2010 passenger vessel (inspected). The Coast Guard has recorded 21 inspections since 2016, most recently in January 2026, along with 26 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 30 January 2026.

Built
2010
Last inspected
30 January 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDF4655
1066774
Flag
UNITED STATES
Maury page id
psix-1066774

Inspections, by type

Years with a record 10 calendar years (2016–2026)
The 21 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Registered dimensions (L × B × D)31.0 ft × 10.5 ft × 6.0 ft
Registered tonnagegross 13 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOMMERCIAL WATER SPORTS INC · CLERMONT, NJ, UNITED STATES · built 2010
Hull materialFRP (Fiberglass)
PropulsionInboard/Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portORANGE BEACH, AL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 4 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Simplified, Gross Ton
10 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 21

30 January 2026 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8304112
21 February 2025 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8082486
3 February 2025 Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8074028
11 December 2023 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7837586
25 July 2023 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7752217
13 March 2023 COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7650018
18 January 2023 Deficiency Check · Drydock Exam · Administrative Inspection · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7624189
21 January 2022 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7383575
25 February 2021 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7146476
25 January 2021 Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7130566
24 January 2020 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6895671
7 March 2019 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6637831
18 December 2018 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6599638
23 January 2018 Administrative Inspection · COI Inspection · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6342419
9 May 2017 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6147225
1 May 2017 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6136762
7 February 2017 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6083946
5 July 2016 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5931564
24 May 2016 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5886481
12 April 2016 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5852879
11 February 2016 Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5813943

Deficiency record · 26

11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 21 February 2025 Resolved
(a) Oceans, coastwise, limited coastwise, and Great Lakes routes. A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry— (1) Six hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.121; and (2) Six hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant. 46 CFR 180.68 (a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 February 2025
Resolved 22 May 2025
Resolution: Vessel owner provided proof of flares onboard vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 March 2022 Resolved
The life ring shall be marked with retroreflective tape. Life ring is not marked with retroreflective tape.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2022
Resolved 2 March 2022
Resolution: Retro tape was renewed on the life ring.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 2 March 2022 Resolved
Life ring life float battery was expired. Replace with battery that is within its service life.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2022
Resolved 2 March 2022
Resolution: Life ring battery was replaced.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 2 March 2022 Resolved
Vessel must carry a fully outfitted first aid kit. Kit aspirin was expired, replace with unexpired aspirin.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2022
Resolved 2 March 2022
Resolution: Expired items in the first aid kit were replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 2 March 2022 Resolved
Portable watertight containers for distress flares shall be of a bright color. Flairs were in a dark colored box. Make container bright colored.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2022
Resolved 2 March 2022
Resolution: Flair kit was made bright colored.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 2 March 2022 Resolved
Each vessel that operates over 3 miles from the coastline must have on board an EPIRB that is registered thought NOAA. Vessels registration doesn't match physical EPIRB unit installed on the vessel. Provide proper documentation.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2022
Resolved 2 March 2022
Resolution: Proper documentation was made available.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 March 2022 Resolved
Machinery must be suitably designed as not to cause undue danger to anyone in the vicinity. Machinery was missing the machinery guard. Replace the guard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2022
Resolved 2 March 2022
Resolution: Machinery guard was replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 2 March 2022 Resolved
Placards containing instructions for the donning and use of the life jackets aboard and be conspicuously placed. Vessel was missing the placard for all types of life jackets on board.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2022
Resolved 2 March 2022
Resolution: Life jacket placard was installed on the vessel for the appropriate style jackets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 March 2022 Resolved
Ventilation of spaces containing diesel machinery must have provisions for closing all supply duck cowls or scoops. Engine room does not have operable vent closures.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2022
Resolved 2 March 2022
Resolution: Covers provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 March 2022 Resolved
Portable fire extinguishers shall be the approved type with the correlating bracket. Fire extinguisher did not have a proper bracket.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2022
Resolved 11 May 2022
Resolution: Photo provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 March 2022 Resolved
Vessel must have 3 2.5 gallon fire buckets. Vessel does not have 3 2.5 buckets.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2022
Resolved 2 March 2022
Resolution: Vessel has functioning 3-2.5 gallon fire buckets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 March 2021 Resolved
An exposed hazard, such as gears or rotating machinery must be properly protected by a cover.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 March 2021
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 8 March 2021 Resolved
Each vessel must be equipped with at least two operable portable battery lights. Vessel was equipped with one light and must be provided with an additional light.
Action required: 10 - Deficiency Rectified
Resolved 8 March 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 February 2021 Resolved
Each ring life buoy must be marked with Type II retroflective material approved IAW 46 CFR 164.018. Ring life buoy retroflective tape must be replaced with Type II.
Action required: 10 - Deficiency Rectified
Resolved 8 March 2021
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 7 March 2019 Resolved
Emergency Broadcast Instructions worn and unreadable. Provide new placard.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 March 2019
Resolution: Provided new emergency broadcast instructions
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 7 March 2019 Resolved
DAPI supervisory training certificates not available. Provide proof of training.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 March 2019
Resolution: Provided certificate showing required training
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 7 March 2019 Resolved
Firefighting servicing reports not available. Provide copies when received from servicing company for pre-engineered system.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 March 2019
Resolution: Provided fire extinguishing servicing reports.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 March 2019 Resolved
User fees not paid. Provide proof of payment.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 March 2019
Resolution: Paid user fees in full online in the presence of the CG.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 22 March 2017 Resolved
Anchor light does not work.
Action required: 705 - Other - as specified
Due 7 April 2017
Resolved 1 May 2017
Resolution: Anchor light works.
Communications › Alarms/Indicators › High Water Alarm
Issued 22 March 2017 Resolved
High water light not working in engine room.
Action required: 705 - Other - as specified
Due 7 April 2017
Resolved 1 May 2017
Resolution: High water alarm worked.
Communications › Radio Communications › VHF Radiotelephone
Issued 22 March 2017 Resolved
VHF radio needs DSC with GPS.
Action required: 705 - Other - as specified
Due 7 April 2017
Resolved 9 May 2017
Resolution: DSC is working properly on VHF.
Documentation › Logs/Records › Logbook (official)
Issued 22 March 2017 Resolved
Vessel needs logs for radio checks, drills, and EPIRB.
Action required: 705 - Other - as specified
Due 7 April 2017
Resolved 1 May 2017
Resolution: Logs were provided.
Documentation › Certificates/Documents › FCC SSL
Issued 22 March 2017 Resolved
Master needs radio operators permit.
Action required: 705 - Other - as specified
Due 7 April 2017
Resolved 1 May 2017
Resolution: Operators permit provided.
Engineering › Bilge Water Management System › Interface Detector
Issued 26 April 2016 Resolved
LED light indicating fwd space automoatic bilge pump is running was not working. Replace LED.
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 May 2016
Resolved 24 May 2016
Resolution: Renewed light
Navigation › Piloting/Steering › Coast Guard Light List
Issued 26 April 2016 Resolved
Vessel had outdated charts and publications. Provide updated charts, coast pilot, light list, and current tables for the area the vessel operates.
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 May 2016
Resolved 5 July 2016
Resolution: Charts and publications were updated.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 26 April 2016 Resolved
3 life jackets were missing retro reflective tape. Add tape as per 46 CFR 185.604
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 May 2016
Resolved 26 April 2016
Resolution: Added tape to the 3 life jackets.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.