HAKUNA MATATA is a 2008 freight ship. The Coast Guard has recorded 5 inspections since 2016, most recently in May 2022, along with 4 deficiencies.

Records from 2016 to 2022. Most recent: inspection, 15 May 2022.

Built
2008
Last inspected
15 May 2022
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 15 May 2022
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2016–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9354167
1067405
Flag
PANAMA
Maury page id
psix-1067405

Documentation record

Tonnage as PSIX records it107612 - Displacement, Metric Ton
80282 - Dead Weight, Metric Ton
76789 - Convention (Subpart B), Gross Ton
27684 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 5

15 May 2022 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7445172
18 August 2017 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6244394
19 July 2016 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5945783
7 March 2016 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5828156
4 January 2016 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5790356

Deficiency record · 4

Engineering › Steering Gear System › Ram Seal
Issued 18 August 2017 Resolved
Steering gear leaking hydraulic oil from the ram seals in 4 different locations.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 August 2017
Resolution: RECEIVED CLASS REPORT AFFIRMING NO LEAKS FROM STEERING GEAR.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 18 August 2017 Resolved
A section of guardrail, which in cases the main engine, is missing.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 August 2017
Resolution: RECEIVED CLASS REPORT ATTESTING TO REPAIR OF GURAD RAIL
Engineering › Diesel Engine (propulsion-direct drive) › Injector (fuel injection)
Issued 18 August 2017 Resolved
Identified 05 oil inlet lines, 01 high pressure fuel line, and main engine local control panel structure tethered to reduce vibration.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 August 2017
Resolution: RECEIVED CLASS REPORT ATTESTING TO PROPER CONDITION OF FUEL LINES, CONTROL PANEL AND OIL LINES.
Engineering › Diesel Engine (propulsion-direct drive) › Distributor (fuel injection)
Issued 4 January 2016 Resolved
Fuel leaks on #1 center, #4 aft, #10 aft, #11 center fuel lines from injection pump to injectors. Fuel piping flanges from main fuel piping to injection pump leaks. *See activity narrative for complete description of deficiency*
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 7 March 2016
Resolution: All items were inspected and replaced to the satisfaction of the attending Classification Representative.

Ownership record