MAURY USCG vessel records
← All vessels

CANYON VOYAGER

CANYON VOYAGER is a 2010 passenger vessel (inspected). The Coast Guard has recorded 13 inspections since 2016, most recently in June 2025, along with 22 deficiencies.

Records from 2016 to 2025. Most recent: inspection, 12 June 2025.

Built
2010
Last inspected
12 June 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 12 June 2025
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

1070037
Flag
UNITED STATES
Maury page id
psix-1070037

Documentation record

Registered dimensions (L × B × D)60.0 ft × 18.5 ft × 5.9 ft
Registered tonnagegross 43 / net 35
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBENTZ BOATS LLC · LEWISTON, ID, UNITED STATES · built 2010
Hull materialAluminum
PropulsionDiesel Outdrive
Hull shapeShip
Hull configurationMonohull
Hailing portHELENA, MT
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 5 June 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it35 - Simplified, Net Ton
43 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 13

12 June 2025 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8157857
9 October 2024 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8020799
12 June 2024 Annual Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7937160
15 June 2023 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7711165
21 February 2023 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7639770
6 June 2022 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7478201
26 May 2021 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7212293
20 July 2020 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7001193
9 October 2019 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6832917
12 June 2019 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6714206
10 May 2018 Deficiency Check · Annual Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6414088
12 May 2017 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6145069
14 May 2016 Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5876694

Deficiency record · 22

07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 12 June 2024 Resolved
46 CFR 176.810(b); For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. If any of the equipment or records have not been properly maintained, a qualified servicing facility may be required to perform the required inspections, maintenance procedures, and hydrostatic pressure tests. Vessel had no servicing history on either of the installed pre-engineered systems.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2024
Resolved 1 July 2025
Resolution: Attended vessel for next annual insp. Vessel had servicing completed for all equipment.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 12 June 2024 Resolved
46 CFR 181.420(c); Only one pre-engineered fixed gas fire extinguishing system is allowed to be installed in each space protected by such a system. Vessel had 02 pre-engineered Halon Systems, only one was hooked up to pull station. Need servicing tech to verify system install.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2024
Resolved 1 July 2025
Resolution: Attended vessel for COI insp. Miscomm between previous inspector and rep. Not pre-enginered, 02 bottles by design for space, both rigged for shutdown and actuation in tandem.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 12 June 2024 Resolved
46 CFR 181.420(b)(3) ; A means to reset devices used to automatically shut down ventilation systems and engines as required by paragraph (a)(3) of this section. Vessel could not demonstrate vessel shutdown/override with installed system.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2024
Resolved 1 July 2025
Resolution: Attended for COI insp. Vessel satisfactorily demonstrated shutdowns. Previous year were unfamiliar.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 12 June 2024 Resolved
46 CFR 180.68(b); A vessel on a lakes, bays, and sounds, or rivers route must carry: Three hand red flare distress signals… Three hand orange smoke distress signals. Vessel flares expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2024
Resolved 1 July 2025
Resolution: Attended for COI insp. Flares current.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 12 June 2024 Resolved
46 CFR 178.410; The weather deck on a flush deck vessel must be watertight. Vessel aft deck access to engine room leaking from any water on deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2024
Resolved 1 July 2025
Resolution: Attended COI insp. No leak detected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 June 2024 Resolved
46 CFR 183.430; Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. Both portable lights batteries were completely dead, lights non-functioning for inspection.
Action required: 10 - Deficiency Rectified
Resolved 12 June 2024
Resolution: Vessel replaced batteries after inspection.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 6 June 2022 Resolved
Fuel tank vent pipes shall be installed to gradient upward to prevent fuel from being trapped in the line. Vent hose dipped below the tank top. Reposition vent hose support to have an upward gradient.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2022
Resolved 21 February 2023
Resolution: Photo of vent with upward gradiate provided.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 6 June 2022 Resolved
Through hull fitting and shutoff valves must be metallic. A decommissioned fresh water line had a sea valve installed after the section of flexible hose. Permanently decommission line with hull insert or capped metallic sea valve. Repair prior to 2023 operations.
Action required: 705 - Other - as specified
Due 1 June 2023
Resolved 21 February 2023
Resolution: Photo of through hull threaded and capped off received.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 6 June 2022 Resolved
A hatch cover must have securing devices and be attached to the hatch frame or coming by captive chains, or other devices of substantial strength to prevent its loss. Provide a securing device for bow hatch.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2022
Resolved 21 February 2023
Resolution: Photo of new wire attached received.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 June 2022 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. Some life jacket stowage location labeling had fallen off. Replace as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2022
Resolved 21 February 2023
Resolution: Photo of corrections received.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 June 2022 Resolved
Alcohol testing must be conducted within 2 hours after a SMI. Vessel did not have alcohol testing available. Provide ability to test within 2 hours after a SMI.
Action required: 10 - Deficiency Rectified
Due 6 June 2022
Resolved 6 June 2022
Resolution: Test ordered.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 May 2021 Resolved
Provide four additional CG approved adult life jackets. Vessel limited to 99 passengers until corrected.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2021
Resolved 6 June 2022
Resolution: Lifejackets Provided
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 May 2021 Resolved
Replace no longer serviceable life rings with CG approved replacements. 46 CFR 180.70
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2021
Resolved 6 June 2022
Resolution: lifebuoy replaced
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 May 2021 Resolved
Place and maintain a copy of the signed stability letter on vessel in location readiliy accesssible to crew and passengers. 46 CFR 176.306
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2021
Resolved 6 June 2022
Resolution: letter displauyed
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 May 2021 Resolved
Provide adequate label for fire station location on aft deck. 46 CFR 185.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2021
Resolved 6 June 2022
Resolution: fire station labeled
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 26 May 2021 Resolved
Provide operational portable lights for operating station and entrance to propulsion machinery space. 46 CFR 183.430
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2021
Resolved 6 June 2022
Resolution: lights provided
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 20 July 2020 Resolved
First aid kit contains expired or missing items. Provide adequate and approved first aid kit. 46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2020
Resolved 30 November 2020
Stability › Watertight Integrity › General
Issued 10 May 2018 Resolved
Install plugs in the two through hull fittings from the previous toilet piping arrangement IAW 46 CFR 179.350(c).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2018
Resolved 27 June 2018
Resolution: Plugs installed, all sat.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 10 May 2018 Resolved
An adult life jacket must be provided for each person carried onboard. Missing 04 life jackets IAW 46 CFR 180.71(a).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 June 2018
Resolution: 04 life jackets added, all sat.
Lifesaving › Hand Flares › Quantity
Issued 10 May 2018 Resolved
Procure flares for the vessels route; 03 smoke and 03 hand red flares IAW 46 CFR 180.68(b).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 June 2018
Resolution: New flares purchased, all sat.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 12 May 2017 Resolved
Provide post type battery for floating water light IAW 46CFR185.726(d).
Action required: 705 - Other - as specified
Due 31 May 2017
Resolved 10 May 2018
Resolution: Post type battery installed.
Lifesaving › Lifebuoys › Stowage
Issued 12 May 2017 Resolved
Install a 3'-6" lanyard with a corrosion resistant clip to attach the floating water light to the life ring buoy IAW 46CFR180.70.
Action required: 705 - Other - as specified
Due 31 May 2017
Resolved 10 May 2018
Resolution: Lanyard attached.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.