MAURY USCG vessel records Sign in
← All vessels

PICHINCHA

PICHINCHA is a 2010 tank ship. The Coast Guard has recorded 20 inspections since 2010, most recently in June 2026, along with 8 deficiencies and 3 operational controls.

Records from 2010 to 2026. Most recent: inspection, 8 June 2026.

Built
2010
Last inspected
8 June 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9422407 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1070211
Flag
PANAMA
—
Maury page id
psix-1070211

Inspections, by type

…with no type recorded4
Years with a record 13 calendar years (2010–2026)
The 20 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it123929 - Displacement, Metric Ton
105093 - Dead Weight, Metric Ton
32926 - Convention (Subpart B), Net Ton
57258 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 20

8 June 2026 PSC B · COC-TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8394869
6 December 2022 PSC B · COC-TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7604827
23 November 2021 PSC B · COC-TVE Annual
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7356096
13 July 2021 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7258057
13 April 2021 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7175233
22 November 2020 COC-TVE Renew · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7099874
6 August 2019 ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6773669
24 August 2018 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6521325
21 August 2018 Ballast Water Examination · COC-TVE Annual · ISPS II Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6508356
18 January 2018 ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6339652
6 September 2017 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6261343
10 August 2017 COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6230778
16 January 2016 ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5798675
6 August 2015 COC-TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5207093
8 August 2014 Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4948413
6 June 2012 ISPS III Exam · COC-TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4331251
23 August 2011 COC-TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4124307
28 January 2011 COE-Administrative
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3934894
15 January 2011 COE-Dockside
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3919822
12 December 2010 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3909231

Deficiency record · 8

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 August 2019 Resolved
Maintenance, testing, and inspections shall be carried out based on the guidelines developed by the Organization and in a manner having due regard to ensuring the reliability of the fire-fighting systems and appliances. The last hydrostatic test of the ship's fixed fire-fighting system (167 CO2 total) was on July 2009. The last hydrostatic test of the pilot CO2 cylinders (08 total) were on May 2009. The last hydrostatic test of the portable foam extinguishers (52 total) were on July 2009.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 August 2019
Resolution: Received satisfactory flag state extension, satisfying the requirements of the attending PSCO.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 21 August 2018 Resolved
74SOLAS(14)II-1/33.1; 10(c); EVERY STEAM PIPE AND EVERY FITTING CONNECTED THERETO THROUGH WHICH STEAM MAY PASS SHALL BE SO DESIGNED, CONSTRUCTED AND INSTALLED AS TO WITHSTAND THE MAXIMUM WORKING STRESSES TO WHICH IT MAY BE SUBJECTED. MAIN STEAM SUPPLY VALVE IN ENGINE ROOM FOR CARBO PUMPS WAS IDENTIFIED TO BE EXCESSIVELY LEAKING STEAM.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 24 August 2018
Engineering › Fuel Oil Service System › Piping
Issued 6 August 2015 Resolved
2050; After any survey the ship under regulations 7, 8, 9 or 10 has been completed, no change shall be made in the structural arrangements, machinery equipment and other items covered by the survey, without the sanction of the Administration. Modified Main Engine MGO drain line from M/E to overfill tank without proper documentation from Class, 74 SOLAS(09) 1/11, 17AC.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 August 2015
Resolution: Corrected to the satisfaction of Class.
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 6 August 2015 Resolved
2510; Vessel must maintain a Ballast Water Management Plan that has been developed for the vessel that will allow those responsible to follow it. Vessel currently does not have a Bio-Fouling Plan on board, 33 CFR2050(g), MEPC Resolution 207(62), 10C.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 August 2015
Resolved 6 August 2015
Resolution: Discussed with the Captain, Chief Mate and Chief Engineer and gave them copies of MEPC and LR plan.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 6 August 2015 Resolved
2510; The operator of a vessel with a capacity of 250 or more barrels of oil shall provide transfer procedures that meet the requirement of the vessel. Vessel does not have bunkering procedures as per CFR. 33CFR155.720, 10C.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 August 2015
Resolved 6 August 2015
Resolution: Discussed with the Captain, Chief Mate and Chief Engineer and gave them a sample copy of transfer procedures.
Documentation › Logs/Records › Oil Record Book
Issued 6 August 2015 Resolved
1710; Oil Record Book shall be provided for every ship 400 gross tons and above. Incorrect recording for MARPOL Annex VI operations for Incinerators and disposal of waste oil were found in the Oil Record Book, MARPOL Annex I/17, 10C.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 6 August 2015
Resolution: Discussed with the Captain, Chief Engineer and Second Engineer.
Fire Fighting › Fixed High-Expansion Foam Fire Extinguishing System › Foam Generator
Issued 6 June 2012 Resolved
0725 - MAINTENANCE, TESTING AND INSP SHALL BE CARRIED OUT BASED ON THE GUIDELINES BY THE ORGANIZATION. THE FIRST PERIODICAL CONTROL OF FOAM CONCENTRATES STORED ON BOARD SHOULD BE PERFORMED AFTER A PERIOD OF THREE YEARS AND, AFTER THAT, EVERY YEAR. LAST FOAM ANALYSIS REPORT WAS DATED SEPT 9, 2008. (>3 YRS) 74SOLAS 2009, II-2/14.2.2.1; MSC/CIRC. 582.5 CODE 17C
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 June 2012
Resolution: Received tech report (Wilhelmsen USHOU/2012/113102651) attesting to a satisfactory foam test result.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 6 June 2012 Resolved
1840 - THE INERT GAS SYSTEM SHALL BE DESIGNED, CONSTRUCTED AND TESTED IN ACCORDANCE WITH THE FIRE SAFETY SYSTEMS CODE. INSTRUMENTATION SHALL BE FITTED FOR CONTINUOUSLY INDICATING AND PERMANENTLY RECORDING WHEN INERT GAS IS SUPPLIED +THE OXYGEN CONTENT OF THE INERT GAS IN THE INERT GAS SUPPLY MAINS ON THE DISCHARGE SIDE OF THE GAS BLOWERS. THE OXYGEN ANALYZER IS UNABLE TO INDICATE 0% OXY CODE 17AC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 June 2012
Resolution: Received Class Survey Report (LAN 1200100) attesting to the proper operation of the vessel''s IG System

Ownership record