ZOUZOU N.

ZOUZOU N. is a 2010 tank ship. The Coast Guard has recorded 1 inspection in 2023, along with 5 deficiencies.

Records in 2023. Most recent: inspection, 8 September 2023.

Built
2010
Last inspected
8 September 2023
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 8 September 2023
Operational controls None recorded without a removal date
Years with a record 1 calendar year (2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9410222
1070773
Flag
LIBERIA
Maury page id
psix-1070773

Documentation record

Tonnage as PSIX records it53430 - Convention (Subpart B), Net Ton
47365 - Simplified, Net Ton
85362 - Convention (Subpart B), Gross Ton
85362 - Simplified, Gross Ton
162204 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 1

8 September 2023 COC-TVE Renew · Deficiency Check · PSC B
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7785206

Deficiency record · 5

07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 8 September 2023 Resolved
For tankers, the protection of the cargo tanks shall be achieved by a fixed inert gas system in accordance with the requirements of the fire safety systems code. PSCO observed a crack 50% of the way around the inert gas scrubber inlet flange.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 8 September 2023
Resolved 11 September 2023
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 8 September 2023 Resolved
The inert gas system shall be capable of inerting and maintaining the atmosphere in cargo tanks with an oxygen content of not more than 5% by volume. PSCO observed that the ship was unable to maintain IG below 5% using ships IG 02 analyzer.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 8 September 2023
Resolved 11 September 2023
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 8 September 2023 Resolved
Where the atmosphere in double-hull spaces cannot be reliably measured using flexible gas sampling hoses, such spaces shall be fitted with permanent gas sampling lines. PSCO observed fixed gas detection system not operational. System display panel stated several system failures.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 8 September 2023
Resolved 11 September 2023
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 September 2023 Resolved
In tankers, electrical equipment, cables, and wiring shall not be installed in hazardous locations unless it conforms with standards not inferior to those acceptable to the organization. PSCO observed numerous lights with cracks in housing preventing them from being acceptable in hazardous locations.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 8 September 2023
Resolved 11 September 2023
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 8 September 2023 Resolved
The oily water seperator shall be provided with arrangements to ensure that any discharge of oily mixtures is automatically stopped when the oil content of the effluent exceeds 15 ppm. The OWS bilge holding tank sample line was not providing effluent to the OCM. PSCO was unable to verify overboard discharge under 15 ppm.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 8 September 2023
Resolved 8 September 2023