MAURY USCG vessel records Sign in
← All vessels

BETHPAGER

BETHPAGER is a 1970 passenger vessel (inspected). The Coast Guard has recorded 52 inspections since 1992, most recently in April 2018, along with 69 deficiencies.

Records from 1992 to 2018. Most recent: inspection, 4 April 2018.

Built
1970
Last inspected
4 April 2018
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WBO5188
107118
Flag
UNITED STATES
369132000
Maury page id
psix-107118

Inspections, by type

…with no type recorded2
Years with a record 23 calendar years (1992–2018)
The 52 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it10 - Regulatory (Subpart C or D), Net Ton
12 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WBO5188MMSI 369132000 · active · compulsorily equipped · granted 29 December 2017, expires 17 December 2027
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 52

4 April 2018 Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6381126
8 December 2017 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6320817
9 November 2017 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6301607
30 January 2017 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6079374
18 August 2016 Internal Structural Exam · COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5973022
23 March 2016 Hull Examination · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5834669
18 November 2015 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5760450
18 November 2015 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5773307
8 December 2011 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4204828
8 September 2011 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 4139450
24 August 2011 COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4123600
17 August 2011 Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4120739
13 December 2010 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3909757
15 November 2010 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3889015
3 December 2008 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3374129
17 September 2008 Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3320050
18 October 2007 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3084447
24 September 2007 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3076811
25 April 2007 Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2915447
30 January 2007 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2864049
7 September 2006 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2771679
18 July 2006 COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2717085
19 September 2005 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2491750
23 May 2005 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2374630
23 May 2005 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2375615
30 December 2004 Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2265942
1 December 2004 Administrative Inspection
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2251861
12 January 2004 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1982472
14 October 2003 Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1928110
17 April 2003 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1775394
30 August 2002 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1667533
27 August 2001 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1426652
11 July 2001 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1073050
19 April 2001 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1463661
13 September 2000 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 824819
2 August 2000 Deficiency Check · Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1413785
19 July 1999 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1415233
7 June 1999 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1401016
29 July 1998 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 795256
20 July 1998 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1472804
3 September 1997 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1442618
24 July 1997 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1425939
10 December 1996 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1097650
29 August 1996 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1416349
20 July 1995 COI Inspection · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1430062
9 June 1995 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 216759
9 June 1995 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 223478
21 September 1994 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 869743
21 September 1994 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1359950
6 May 1994 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1473464
5 October 1993 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1452980
18 September 1992 Hull Examination · Initial Certification
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 938511

Deficiency record · 69

Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 9 November 2017 Resolved
Vessel is required to have a valid Certificate of Documentation. Vessel's Certificate of Documentation is expired. 46 CFR 67.7
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 December 2017
Resolved 7 December 2017
Resolution: Vessel rep submitted proof of valid COD.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 9 November 2017 Resolved
Vessel's life float must have a floating waterlight. Vessel's waterlight for life float is inoperative. 46 CFR 180.175
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 December 2017
Resolution: Vessel replaced floating waterlight with a properly operating floating waterlight.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 9 November 2017 Resolved
Tubing connections and fittings must be of non-ferrous drawn/forged metal. Replace hose connections to primary fuel filter. 46 CFR 182.455
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 December 2017
Resolved 7 December 2017
Resolution: Vessel replaced hose connections for the primary fuel filter with a non-ferrous metal.
Lifesaving › Lifefloat › Painter
Issued 9 November 2017 Resolved
Painter attached to the life float is not of sufficient length. Attach a painter of at least 100 feet in length to the life float. 46 CFR 180.175(f)(3)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 December 2017
Resolution: Vessel installed a painter meeting regulatory requirements.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 18 November 2015 Resolved
Owner/Operator cannot provide documentation of crew enrolled in drug consortium. Provide proof of enrollment for all vessel crew members.
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 December 2015
Resolved 19 November 2015
Resolution: O/O Provided proof of enrollment in Drug Consortium.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 18 November 2015 Resolved
Vessel does not have updated Tide Table and Light List. Obtain updated publications.
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 December 2015
Resolved 19 November 2015
Resolution: O/O Provided updated Publications.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 8 September 2011 Resolved
Operating Controls - Improper Installation
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 October 2011
Resolved 2 November 2011
Resolution: Vessel has installed a pre-engineered fire fighting system that shuts down the main engine when the system is activated.
Construction/Loadline › Hull › Longitudinal Frame
Issued 13 December 2010 Resolved
Planks pulling away from frame in stbd side forepeak. Vessel must make repairs as necessary NLT next scheduled out of water inspection (Aug 2011) to the satisfaction of attending CG marine inspector IAW 46 CFR 176.20-5.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 August 2011
Resolution: Pulled a fastner from this location; no concern.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 13 December 2010 Resolved
Vessel must complete operational test before the start of the 2011 season to the satisfaction of attending CG marine inpsector IAW 46 CFR 176.30-1.
Action required: 705 - Other - as specified
Resolved 24 August 2011
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 15 November 2010 Resolved
Deckhand was not enrolled in Drug and Alcohol consortium for the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 December 2010
Resolved 13 December 2010
Resolution: Owner provided documentation of deckhand''s enrollment and testing in Drug and Alcohol Consortium.
Documentation › Certificates/Documents › FCC SSL
Issued 15 November 2010 Resolved
FCC Radio Safety Telephone Certificate was expired. Restricted to 1000' from Shore.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 December 2010
Resolved 13 December 2010
Resolution: Owner provided new FCC Safety Certificate - expires 09 Dec 2015.
Documentation › Markings/Placards › Warning Signs
Issued 15 November 2010 Resolved
Post emergency instruction placard at the operating station.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 December 2010
Resolved 13 December 2010
Resolution: Owner posted emergency instruction placard at operating station.
Documentation › Manuals/Policy Documentation › Maneuvering Information
Issued 15 November 2010 Resolved
Vessel missing tides and currents list.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 December 2010
Resolved 13 December 2010
Resolution: Owner provided tides and currents list.
Documentation › Manuals/Policy Documentation › Maneuvering Information
Issued 15 November 2010 Resolved
Missing Light List for vessels operating area.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 December 2010
Resolved 13 December 2010
Resolution: Owner provided Light List.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 15 November 2010 Resolved
Replace Grabline around lifebouy.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 December 2010
Resolved 13 December 2010
Resolution: Owner installed new grabline around the body of the ringbuoy.
Lifesaving › Lifebuoys › Serviceable
Issued 15 November 2010 Resolved
Replace reflective tape and place on both sides of Lifebouy and replace clip to floatlight.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 December 2010
Resolved 13 December 2010
Resolution: Owner replaced retroreflective tape and float light clip.
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 15 November 2010 Resolved
Provide Emergency Portable fire pump.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 December 2010
Resolved 13 December 2010
Resolution: Owner provided new emergency portable fire/bilge pump.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 15 November 2010 Resolved
Repair leaking water at shaft packing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 December 2010
Resolved 13 December 2010
Resolution: Shaft packing tightened; no excessive leakage.
Engineering › Bilge Water Management System › Not Operational
Issued 15 November 2010 Resolved
Repair submerged bilge pump.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 December 2010
Resolved 13 December 2010
Resolution: Owner proved proper operation of submersible bilge pump.
Operations/Management › Ballast Water Managment › Ballast Water Discharge
Issued 15 November 2010 Resolved
Remove excessive oil from bilge.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 December 2010
Resolved 13 December 2010
Resolution: Bilge clean of oil.
Engineering › Fuel Oil Service System › Valve
Issued 3 December 2008 Resolved
46 CFR 182.455 (b)(4) Install shutoff Valve, at the tank, so it can be manually operated from outside the compartment. Current configuration does not meet this requirement. (Cite Old "T" 46 CFR 182.20-40 (b)(3))
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 December 2008
Resolved 18 December 2008
Resolution: New Emergency fuel shut off valve was installed at the tank and positioned outside the compartment. Access to valve was greatly improved and is in compliance with Applicable CFR.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 3 December 2008 Resolved
46 CFR 180.175 (f)(4) Attach a lanyard resistant to deterioration from ultra violet light and a minimum length of 18 feet. Current lanyard does not meet length requirement.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 December 2008
Resolved 18 December 2008
Resolution: Replaced lanyard with appropriate length.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 24 September 2007 Resolved
Make temporary repairs to the main engine exhaust pipe, remove and present for inspection no later than 17 November 2007.
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 November 2007
Resolved 18 October 2007
Fire Fighting › Fixed Gas Fire Extinguishing System › Control Valve
Issued 24 September 2007 Resolved
Provide a manual pull for the fixed gas fire extinguishing system no later than 12 October 2007. (And provide the owners manual for that system).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 October 2007
Resolved 18 October 2007
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 6 September 2007 Resolved
Provide all navigation pubs IAW 46 CFR 184.420.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 September 2007
Resolved 24 September 2007
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 6 September 2007 Resolved
Renew the life float water light and sea painter prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2007
Resolved 24 September 2007
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 6 September 2007 Resolved
Provide appropriate first aid kit.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2007
Resolved 24 September 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Pump, Positive Displacement
Issued 6 September 2007 Resolved
Make repairs to the main engine R/W pump prior to carrying passengers.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2007
Resolved 24 September 2007
Construction/Loadline › Hull › Keel
Issued 6 September 2007 Resolved
Investigate the leakage IWO the port, garboard seam aft.
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 September 2007
Resolved 24 September 2007
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 6 September 2007 Resolved
Make repairs to the main propeller shaft stuffing box.
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 September 2007
Resolved 24 September 2007
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 6 September 2007 Resolved
Remove oil from bilges.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 September 2007
Resolved 24 September 2007
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 6 September 2007 Resolved
Provide info on annual servicing of the fixed fire extinguishing system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 September 2007
Resolved 24 September 2007
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 18 July 2006 Resolved
Provide proper, CG approved retro tape for all child PFD's.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 September 2006
Resolved 13 September 2006
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 18 July 2006 Resolved
Prove current membership to a maritime consortium. (Master).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 September 2006
Resolved 13 September 2006
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 18 July 2006 Resolved
Provide approved fire extinguisher bracket for both BC II's.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 September 2006
Resolved 13 September 2006
Engineering › Bilge Water Management System › Piping
Issued 18 July 2006 Resolved
Install valves on the bilge pump discharge lines (at the thru hull fittings).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 September 2006
Resolved 13 September 2006
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 18 July 2006 Resolved
Install lagging on main engine exhaust pipe.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 September 2006
Resolved 13 September 2006
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 18 July 2006 Resolved
Provide FCC Radio Safety Certificate.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 September 2006
Resolved 13 September 2006
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 18 July 2006 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 September 2006
Resolved 13 September 2006
Operations/Management › Drills/Instruction › Not Conducted
Issued 18 July 2006 Resolved
Provide proof of valid CPR and first aid training.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 September 2006
Resolved 13 September 2006
Operations/Management › Drills/Instruction › Not Conducted
Issued 30 December 2004 Resolved
Conduct man overboard and fire drills in the presence of the attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2005
Resolution: Vessel operator conduct satisfactory man overboard and fire drill.
Lifesaving › Lifefloat › Painter
Issued 30 December 2004 Resolved
Attach lifefloat painter to vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 September 2005
Resolution: Vessel attached lifefloat painter to vessel with hydrostatic release.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 30 December 2004 Resolved
Provide proof of crew enrollment in USCG approved drug testing program.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 September 2005
Resolution: Vessel representative provided proof of crew enrollement in approved drug testing program.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 December 2004 Resolved
Vessel must undergo annual exam prior to operating with passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 December 2004
Resolution: Conducted annual exam.
Lifesaving › Lifebuoys
Issued 15 October 2003 Resolved
Replace reflective tape on ring bouy.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 January 2004
Resolution: Purchased and applied required retro-reflective tape to ring buoy.
Navigation › Piloting/Steering
Issued 15 October 2003 Resolved
Provide tide and current tables. LEGACY COMPONENT DESC: Tide/Tidal Current Tables
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 January 2004
Resolution: Purchased and stowed onboard required tide and current tables.
Engineering
Issued 27 August 2001 Resolved
SECURE TACHOMETER IN ENGINE COMPARTMENT.
Condition: Unknown
Due 27 August 2001
Resolved 17 September 2001
Documentation
Issued 27 August 2001 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 27 August 2001
Resolved 17 September 2001
Engineering
Issued 27 August 2001 Resolved
PROVE ENGINE TACHOMETER AT OPERATING STATION IS OPERABLE.
Condition: Unknown
Due 27 August 2001
Resolved 17 September 2001
Fire Fighting
Issued 27 August 2001 Resolved
PROVIDE ADEQUATE HOSE FOR PORTABLE BILGE PUMP.
Condition: Unknown
Due 27 August 2001
Resolved 17 September 2001
Electrical
Issued 27 August 2001 Resolved
LABEL ELETRICAL PANEL.
Condition: Unknown
Due 27 August 2001
Resolved 17 September 2001
Lifesaving
Issued 27 August 2001 Resolved
CHANGE PLACARD OR ADD ADDITIONAL CHILD SIZE PFD'S TO REFLECT ACTUAL NUMBER OF PFD'S STOWED._x001C_
Condition: Unknown
Due 27 August 2001
Resolved 17 September 2001
Engineering
Issued 27 August 2001 Resolved
STOP LEAKAGE ON RAW WATER IMPELLER HOUSING.
Condition: Unknown
Due 27 August 2001
Resolved 17 September 2001
Unknown
Issued 27 August 2001 Resolved
PROVE PORT LIGHT IS OPERABLE.
Condition: Unknown
Due 27 August 2001
Resolved 17 September 2001
Unknown
Issued 27 August 2001 Resolved
REPLACE CRACKED PILOTHOUSE WINDOW WITH SAFETY GLASS.
Condition: Unknown
Due 27 August 2001
Resolved 17 September 2001
Documentation
Issued 27 August 2001 Resolved
PROVIDE BRIDGE LOG AND TRAINING RECORD.
Condition: Unknown
Due 27 August 2001
Resolved 17 September 2001
Lifesaving
Issued 27 August 2001 Resolved
PROVIDE 100FT PAINTER FOR LIFEFLOAT.
Condition: Unknown
Due 27 August 2001
Resolved 17 September 2001
Lifesaving
Issued 27 August 2001 Resolved
MARK PADDLES ON LIFEFLOAT WITH VESSEL NAME AND TIE INTO LIFEFLOAT.
Condition: Unknown
Due 27 August 2001
Resolved 17 September 2001
Lifesaving
Issued 27 August 2001 Resolved
MARK LIFEFLOAT WITH VESSELS NAME.
Condition: Unknown
Due 27 August 2001
Resolved 17 September 2001
Lifesaving
Issued 27 August 2001 Resolved
REPLACE LIFEFLOAT WATERLIGHT.
Condition: Unknown
Due 27 August 2001
Resolved 17 September 2001
Lifesaving
Issued 27 August 2001 Resolved
REPLACE ONE ADULT SIZE PFD.
Condition: Unknown
Due 27 August 2001
Resolved 17 September 2001
Lifesaving
Issued 19 April 2001 Resolved
AT VESSEL REP'S REQUEST VESSEL RESTRICTED TO RIVERS ROUTE NO MORE THAN ONE MILE FROM SHORE DURING COLD WATER MONTHS (NOV1 - MAY31) UNTIL ADDITIONAL PRIMARY LIFESAVING EQUIPMENT IS PROVIDE I.A.W. WITH 46 CFR 180.200.
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Lifesaving
Issued 2 August 2000 Resolved
RENEW EXPIRED VISUAL DISTRESS SIGNALS. (46CFR180.68)
Condition: Unknown
Due 5 August 2000
Resolved 11 August 2000
Lifesaving
Issued 2 August 2000 Resolved
RENEW EXPIRED MEDICATIONS IN FIRST AID KIT. (46CFR184.710)
Condition: Unknown
Due 5 August 2000
Resolved 11 August 2000
Fire Fighting
Issued 2 August 2000 Resolved
PROVIDE A FIXED FIRE DETECTION SYSTEM FOR MACHINERY SPACE. (46CFR181.400)
Condition: Unknown
Due 2 August 2000
Resolved 2 August 2000
Lifesaving
Issued 2 August 2000 Resolved
PROVIDE LIFEJACKET DONNING PLACARD. (46CFR185.516)
Condition: Unknown
Due 5 August 2000
Resolved 11 August 2000
Fire Fighting
Issued 2 August 2000 Resolved
PROVIDE (01) ONE ADDITIONAL FIRE BUCKET WITH LANYARD, AND LABELED "FIRE BUCKET". (46CFR181.610)
Condition: Unknown
Due 5 August 2000
Resolved 11 August 2000
Lifesaving
Issued 20 July 1998 Resolved
PROVIDE TYPE II RETRO REFLECTIVE TAPE FOR RING LIFE BUOY. (46 CFR 185.604)
Condition: Unknown
Due 20 July 1998
Resolved 20 July 1998
Navigation
Issued 20 July 1998 Resolved
PROVIDE CURRENT NAVIGATIONAL CHART FOR AREA OF OPRERATION. (46 CFR 184.420)
Condition: Unknown
Due 20 July 1998
Resolved 20 July 1998

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.