MAURY USCG vessel records
← All vessels

SILDA

SILDA is a 2009 public freight. The Coast Guard has recorded 2 inspections in 2017, along with 3 deficiencies.

Records in 2017. Most recent: inspection, 6 September 2017.

Built
2009
Last inspected
6 September 2017
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 6 September 2017
Operational controls None recorded without a removal date
Years with a record 1 calendar year (2017)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9515280
9HA4224
1071640
Flag
MALTA
Maury page id
psix-1071640

Documentation record

Tonnage as PSIX records it16223 - Dead Weight, Ton
21977 - Displacement, Ton
11927 - Convention (Subpart B), Gross Ton
5507 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 2

6 September 2017 Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6261176
30 May 2017 ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6159971

Deficiency record · 3

Fire Fighting › Structural - A Class Divisions › Doors
Issued 30 May 2017 Resolved
Door required to be self closing shall not be fitted with hold back hooks. Galley A class door was found with hold backs. 74SOLAS 09 Con II-2/9.4.2.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 September 2017
Resolution: Hold backs where removed from galley doors.
Engineering › Diesel Engine (auxiliary) › Crankcase
Issued 30 May 2017 Resolved
Machinery must be in working conditions as intended. Diesel generator #1, cylinder 2 and 3 oil pressure relief hose is severly worn and missing clamps. 74SOLAS 09Con. II-2/9.4.2.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 September 2017
Resolution: Repair generator by placing on hise clamps and new rubber hose.
Fire Fighting › Means of Escape › Doorways
Issued 30 May 2017 Resolved
Machinery space provided mean of escape must be a slef closing door. Main machinery deck emergency escape door does not close entirely. 74 SOLAS 09Con. II-2/13.4.2.1.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 September 2017
Resolution: Adjusted hinges so door completely closes.

Ownership record