Records in 2016. Most recent: inspection, 2 March 2016.
Deck/Cargo › Inert Gas System › Gas Regulating Valve
Issued 2 March 2016
Resolved
1850 - FIRE PROTECTION DECK AREA - SUITABLE MEANS SHALL BE PROVIDED FOR THE ZERO AND SPAN CALIBRATION OF FIXED GAS CONCENTRATION MEASUREMENT INSTRUMENTS. MANUFACTURER'S SPECIFIED SET POINT FOR SPAN MEASUREMENT WAS IMPROPERLY PROGRAMMED INTO IGS OXYGEN ANALYZER. 74 SOLAS (2009 CONSOLIDATED) II-2/4.5.5
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2016
Resolved 3 March 2016
Resolution: Documentation was received from Marine Surveyor including statement and IGS manual PDF file. PSCO reviewed information and documentation requested. All sat. Deficiency revised to reflect correct deficiency language.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 2 March 2016
Resolved
1820 - CARGO PUMP ROOM/HANDLING SPACES - NO ELECTRICAL EQUIPMENT SHALL BE INSTALLED IN ANY SPACE WHERE FLAMMABLE MIXTURES ARE LIABLE TO COLLECT UNLESS THE ADMINISTRATION IS SATISFIED THAT SUCH EQUIPMENT IS OF A TYPE WHICH WILL NOT INGNITE THE MIXTURE CONCERNED. CARGO PUMP ROOM CONTAINED 5 LIGHT CASES THAT WERE CRACKED, AND ONE CASE WAS MISSING THE GROUNDING WIRE. 74 SOLAS (2009 CONS.) II-1/45.10.2
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2016
Resolved 3 March 2016
Resolution: 04 light cases were replaced and properly installed to the satisfaction of PSCO. 01 light case cracked from the inside when being installed by a crew member, so the electrical system from that light was isolated until the new case is installed.
Electrical › Electrical Distribution System (emergency) › Ground Detection
Issued 2 March 2016
Resolved
0950 - ELECTRICAL EQUIPMENT IN GENERAL - ELECTRICAL INSTALLATIONS SHALL BE SUCH THAT THE SAFETY OF PASSENGERS, CREW AND SHIP FROM ELECTRICAL HAZARDS WILL BE ENSURED. GROUND FAULT DETECTION SYSTEM ON 440 VOLT EMERGENCY SWITCHBOARD WAS NOT OPERABLE. 74 SOLAS (2009 CONSOLIDATED)II-1/40.1.3
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 3 March 2016
Resolved 3 March 2016
Resolution: Vessel attended by Marine Inspector. All sat.
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 2 March 2016
Resolved
1835 - CARGO VENT SYSTEM - THE VENTING SYSTEM SHALL BE PROVIDED WITH DEVICES TO PREVENT THE PASSAGE OF FLAME INTO THE CARGO TANKS. P/V VALVE FLAME SCREENS WERE HOLED. 74 SOLAS(2009 CONSOLIDATED)II-2/4.5.3.3
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2016
Resolved 3 March 2016
Resolution: All flame screens found on the 14 P/V Valves were replaced. All Sat.
Operations/Management › Pollution › Control of Discharge of Oil
Issued 2 March 2016
Resolved
1740 - OIL DISCHARGE MON/CONTR SYSTEM - INSTRUCTIONS AS TO THE OPERATION OF THE SYSTEM SHALL BE IN ACCORDANCE WITH AN OPERATIONAL MANUAL APPROVED BY THE ADMINISTRATION. CREW COULD NOT DEMONSTRATE PROPER OPERATION OF THE ODME. 73 MARPOL(2011 CONS.)I/31.4
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2016
Resolved 3 March 2016
Resolution: Chief Mate proved proper operation of ODME and testing procedures were properly followed. All Sat.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 2 March 2016
Resolved
1735 - PUMPING DISCHARGE ARRANGEMENTS - THE LAST METER OF EACH END OF A VAPOR PIPING MUST BE PAINTED IN THE SEQUENCE OF RED/YELLOW/RED. PORT SIDE VAPOR PIPING WAS NOT PAINTED IN ACCORDANCE WITH THE REGULATION. 46 CFR 39.2001(h)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2016
Resolved 3 March 2016
Resolution: Vapor Control Line was painted IAW the regulations. All Sat.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 2 March 2016
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 2 April 2016
Resolved 21 April 2016
Resolution: Vessel undertook successful recommended ISM audit. All sat.