ADELE MARINA RIZZO

ADELE MARINA RIZZO is a 2009 tank ship. The Coast Guard has recorded 1 inspection in 2016, along with 7 deficiencies.

Records in 2016. Most recent: inspection, 2 March 2016.

Built
2009
Last inspected
2 March 2016
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 2 March 2016
Operational controls None recorded without a removal date
Years with a record 1 calendar year (2016)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9434890
1072403
Flag
ITALY
Maury page id
psix-1072403

Documentation record

Tonnage as PSIX records it108835 - Dead Weight, Ton
60185 - Convention (Subpart B), Gross Ton
60185 - Simplified, Gross Ton
33762 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 1

2 March 2016 Ballast Water Examination · Administrative Inspection · COC-TVE Renew · Deficiency Check · ISPS II Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5824398

Deficiency record · 7

Deck/Cargo › Inert Gas System › Gas Regulating Valve
Issued 2 March 2016 Resolved
1850 - FIRE PROTECTION DECK AREA - SUITABLE MEANS SHALL BE PROVIDED FOR THE ZERO AND SPAN CALIBRATION OF FIXED GAS CONCENTRATION MEASUREMENT INSTRUMENTS. MANUFACTURER'S SPECIFIED SET POINT FOR SPAN MEASUREMENT WAS IMPROPERLY PROGRAMMED INTO IGS OXYGEN ANALYZER. 74 SOLAS (2009 CONSOLIDATED) II-2/4.5.5
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2016
Resolved 3 March 2016
Resolution: Documentation was received from Marine Surveyor including statement and IGS manual PDF file. PSCO reviewed information and documentation requested. All sat. Deficiency revised to reflect correct deficiency language.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 2 March 2016 Resolved
1820 - CARGO PUMP ROOM/HANDLING SPACES - NO ELECTRICAL EQUIPMENT SHALL BE INSTALLED IN ANY SPACE WHERE FLAMMABLE MIXTURES ARE LIABLE TO COLLECT UNLESS THE ADMINISTRATION IS SATISFIED THAT SUCH EQUIPMENT IS OF A TYPE WHICH WILL NOT INGNITE THE MIXTURE CONCERNED. CARGO PUMP ROOM CONTAINED 5 LIGHT CASES THAT WERE CRACKED, AND ONE CASE WAS MISSING THE GROUNDING WIRE. 74 SOLAS (2009 CONS.) II-1/45.10.2
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2016
Resolved 3 March 2016
Resolution: 04 light cases were replaced and properly installed to the satisfaction of PSCO. 01 light case cracked from the inside when being installed by a crew member, so the electrical system from that light was isolated until the new case is installed.
Electrical › Electrical Distribution System (emergency) › Ground Detection
Issued 2 March 2016 Resolved
0950 - ELECTRICAL EQUIPMENT IN GENERAL - ELECTRICAL INSTALLATIONS SHALL BE SUCH THAT THE SAFETY OF PASSENGERS, CREW AND SHIP FROM ELECTRICAL HAZARDS WILL BE ENSURED. GROUND FAULT DETECTION SYSTEM ON 440 VOLT EMERGENCY SWITCHBOARD WAS NOT OPERABLE. 74 SOLAS (2009 CONSOLIDATED)II-1/40.1.3
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 3 March 2016
Resolved 3 March 2016
Resolution: Vessel attended by Marine Inspector. All sat.
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 2 March 2016 Resolved
1835 - CARGO VENT SYSTEM - THE VENTING SYSTEM SHALL BE PROVIDED WITH DEVICES TO PREVENT THE PASSAGE OF FLAME INTO THE CARGO TANKS. P/V VALVE FLAME SCREENS WERE HOLED. 74 SOLAS(2009 CONSOLIDATED)II-2/4.5.3.3
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2016
Resolved 3 March 2016
Resolution: All flame screens found on the 14 P/V Valves were replaced. All Sat.
Operations/Management › Pollution › Control of Discharge of Oil
Issued 2 March 2016 Resolved
1740 - OIL DISCHARGE MON/CONTR SYSTEM - INSTRUCTIONS AS TO THE OPERATION OF THE SYSTEM SHALL BE IN ACCORDANCE WITH AN OPERATIONAL MANUAL APPROVED BY THE ADMINISTRATION. CREW COULD NOT DEMONSTRATE PROPER OPERATION OF THE ODME. 73 MARPOL(2011 CONS.)I/31.4
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2016
Resolved 3 March 2016
Resolution: Chief Mate proved proper operation of ODME and testing procedures were properly followed. All Sat.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 2 March 2016 Resolved
1735 - PUMPING DISCHARGE ARRANGEMENTS - THE LAST METER OF EACH END OF A VAPOR PIPING MUST BE PAINTED IN THE SEQUENCE OF RED/YELLOW/RED. PORT SIDE VAPOR PIPING WAS NOT PAINTED IN ACCORDANCE WITH THE REGULATION. 46 CFR 39.2001(h)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2016
Resolved 3 March 2016
Resolution: Vapor Control Line was painted IAW the regulations. All Sat.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 2 March 2016 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 2 April 2016
Resolved 21 April 2016
Resolution: Vessel undertook successful recommended ISM audit. All sat.