MAURY USCG vessel records
← All vessels

CONTI COURAGE

CONTI COURAGE is a 2005 freight ship. The Coast Guard has recorded 19 inspections since 2016, most recently in June 2026, along with 6 deficiencies and 1 operational control.

Records from 2016 to 2026. Most recent: inspection, 19 June 2026.

Built
2005
Last inspected
19 June 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 19 June 2026
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9293789
1072677
Flag
LIBERIA
Maury page id
psix-1072677

Documentation record

Tonnage as PSIX records it106936 - Dead Weight, Metric Ton
140936 - Displacement, Metric Ton
90449 - Convention (Subpart B), Gross Ton
59328 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 19

19 June 2026 PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8408176
8 January 2026 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8292322
5 January 2026 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8290366
2 September 2025 PSC B
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8220670
9 April 2025 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8109091
28 March 2025 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8101150
12 March 2024 PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7875925
8 March 2024 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7878028
27 November 2023 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7829716
25 May 2023 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7695720
19 October 2022 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7580256
27 September 2022 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7566874
9 January 2022 PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7370409
23 July 2019 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6758702
16 July 2019 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6751977
29 December 2016 Random ISPS/MTSA-No PSC
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6063396
26 December 2016 ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6062434
18 November 2016 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6043228
14 November 2016 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6040726

Deficiency record · 6

03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 2 September 2025 Resolved
Where coamings are prodivided they shall be of substantial consutrction. PSCO observed cargo hold 05's coamings heavily corroded and preventing weathertightness. 1966 ICLL ANNEX 1/16.1 - ACTION 40BC
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 January 2026
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 16 July 2019 Resolved
THE PURPOSE OF THIS REGULATION IS TO PREVENT THE IGNITION OF COMBUSTIBLE MATERIALS OR FLAMMABLE LIQUIDS. FOR THIS PURPOSE, THE FOLLOWING FUNCTIONAL REQUIREMENTS SHALL BE MET: IGNITION SOURCES SHALL BE RESTRICTED. PSCO OBSERVED OIL SOAKED LAGGING ON FUEL PUMPS #10, 9, 8, 7, 4, & 3.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2019
Resolution: Received satisfactory class report. See document for additional details.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 16 July 2019 Resolved
ELECTRICAL INSTALLATIONS SHALL BE SUCH THAT: ELECTRICAL SERVICES ESSENTIAL FOR SAFETY WILL BE ENSURED UNDER VARIOUS EMERGENCY CONDITIONS. PSCO OBSERVED MULTIPLE LOCATIONS OF EMERGENCY LIGHTING TO BE INOPERABLE WITH MULTIPLE HAVING BROKEN LIGHT FIXTURE CASING.
Action required: 15 - Rectify deficiencies by next port
Resolved 17 July 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 July 2019 Resolved
THE DESIGN SHALL HAVE REGARD TO MATERIALS USED IN CONSTRUCTION, THE PURPOSE FOR WHICH THE EQUIPMENT IS INTENDED, THE WORKING CONDITIONS TO WHICH IT WILL BE SUBJECTED AND THE ENVIRONMENTAL CONDITIONS ONBOARD. PSCO OBSERVED CRACKED SIGHT SAFETY GLASS ON FUEL PUMPS #10, 9, 8, 7, 4, & 3.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 July 2019
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 16 July 2019 Resolved
THE PURPOSE OF THIS REGULATION IS TO PREVENT THE IGNITION OF COMBUSTIBLE MATERIALS OR FLAMMABLE LIQUIDS. FOR THIS PURPOSE THE FOLLOWING FUNCTIONAL REQUIREMENTS SHALL BE MET: MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF LFAMMABLE LIQUIDS. PSCO OBSERVED HYDRAULIC OIL LEAK ON STEERING PUMP #1.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 July 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 16 July 2019 Resolved
THE NUMBER OF OPENINGS IN WATERTIGHT SUBDIVISIONS IS TO BE KEPT TO A MINIMUM COMPATIBLE WITH THE DESIGN AND PROPER WORKING OF THE SHIP. PSCO OBSERVED D.P. TANK COVER UNBOLTED AND COMPLETELY REMOVED.
Action required: 10 - Deficiency Rectified
Resolved 16 July 2019

Ownership record