CMA CGM FIGARO is a 2010 freight ship. The Coast Guard has recorded 29 inspections since 2010, most recently in May 2026, along with 3 deficiencies and 2 operational controls.

Records from 2010 to 2026. Most recent: inspection, 3 May 2026.

Built
2010
Last inspected
3 May 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9450600 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9HA5577
1072852
Flag
MALTA
—
Maury page id
psix-1072852

Inspections, by type

…with no type recorded1
Years with a record 13 calendar years (2010–2026)
The 29 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it108869 - Dead Weight, Metric Ton
140964 - Displacement, Metric Ton
90931 - Convention (Subpart B), Gross Ton
61650 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 29

3 May 2026 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8359169
2 May 2026 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8360539
21 January 2026 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8299665
23 October 2025 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8257493
28 October 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7585578
8 April 2022 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7425705
6 April 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7425725
4 April 2022 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7424253
7 January 2022 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7377074
1 January 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7374439
13 October 2021 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7332010
7 October 2021 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7326932
5 October 2021 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7327112
12 April 2021 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7173799
24 January 2021 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7127586
19 January 2021 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7126564
26 October 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7084121
23 October 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7083058
16 October 2019 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6835989
15 October 2019 ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6834492
5 October 2017 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6282039
24 September 2016 ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6003584
12 September 2015 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5235587
15 July 2015 Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5184978
20 August 2014 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4960323
17 July 2012 ISPS II Exam · PII Safety Exam · Ballast Water Examination · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4381450
2 July 2011 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4059582
4 December 2010 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3904079
11 October 2010 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3867849

Deficiency record · 3

Lifesaving › Line-Throwing Appliances › Projectiles
Issued 17 July 2012 Resolved
0699 - Line throwing appliances shall be capable to throw a line and contain not less than 4 projectiles. Devices contained no projectiles. 74SOLAS09 Ch. III/18, LSA Code Ch. 7.1.1.2
Action required: 705 - Other - as specified
Due 24 July 2012
Resolved 18 July 2012
Resolution: Recieved delivery reciept for 4 projectiles, recieved in Neward, NJ 17JUL2012.
Lifesaving › Launching Appliances › Suspension Chain
Issued 17 July 2012 Resolved
0610 - Each lifeboat shall be stowed in a state of continuous readiness. Port side lifeboat forward fall wire as well as remote control wire are stretched/torn. 74SOLAS09 Ch. III/13.1.3
Action required: 17 - Rectify deficiencies prior to departure
Due 18 July 2012
Resolved 18 July 2012
Resolution: Recieved report from class on behalf of Administration stating that the administration is aware of the problem and arangements have been made to repair the falls in Savannah, GA. Report ammended Safety Equipment Certif.
Personnel › Certificates/Documents/Licenses › STCW Certificate, OIC of Navigational Watch
Issued 17 July 2012 Resolved
0220 - Certificates for officers issued shall be endorsed by the administration of the ship. Deck officer "Mailat Viorel" lack French endorsement. STCW Convention 2010 Article VI(2)
Action required: 17 - Rectify deficiencies prior to departure
Due 18 July 2012
Resolved 18 July 2012
Resolution: Recieved copy of new endorsement from Administration.