Records from 1990 to 2008. Most recent: inspection, 26 September 2008.
Documentation record
Registered dimensions (L × B × D)41.0 ft × 18.3 ft × 4.5 ft
Registered tonnagegross 44 / net 35
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJACKUP BOAT BUILDERS INC · CAERNARVON, LA, UNITED STATES · built 1970
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portERATH, LA
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationExpired · issued 30 June 2004
Service, as the file records itCommercial Fishing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it44 - Regulatory (Subpart C or D), Gross Ton
35 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 26
26 September 2008
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3333272
29 March 2004
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2033545
11 October 2002
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1688492
24 April 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1608974
24 August 2001
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1423637
11 April 2000
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1439012
10 March 2000
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 766822
16 February 2000
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 202067
14 June 1999
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 809467
11 June 1999
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1461175
20 March 1998
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1394918
22 April 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1388331
21 February 1996
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1383193
11 February 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1185845
17 February 1995
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1454151
10 August 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 669637
24 May 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 859458
7 February 1994
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1359720
1 February 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 13318
1 February 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 90430
1 February 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 212715
24 September 1992
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1447195
14 September 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 937833
8 July 1991
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 938430
4 January 1991
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1242949
4 May 1990
Initial Certification · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 920042
Lifesaving
Issued 11 April 2000
Resolved
Demonstrate compliance with the 8th U.S. Coast Guard District Policy Ltr. dated 12NOV98 "Rescue Boat Requirements on Offshore Supply Vessels" to the satisfaction of the attending Marine Inspector.
Condition: Unknown
Due 11 April 2000
Resolved 11 April 2000
Navigation
Issued 11 June 1999
Resolved
PRIOR TO PLACING VSL IN SERVICE, PROVE PROPER OPERATION OR RADAR.
Condition: Unknown
Due 11 June 1999
Resolved 11 June 1999
Fire Fighting
Issued 11 June 1999
Resolved
PRIOR TO PLACING VSL IN SERVICE, PROVE PROPER OPERATION OF FIRE PUMP.
Condition: Unknown
Due 11 June 1999
Resolved 11 June 1999
Lifesaving
Issued 11 June 1999
Resolved
PROVIDE RESCUE BOAT AS PER 8TH DISTRICT'S RESCUE BOAT REQUIREMENT LETTER DATED 12NOV98
Condition: Unknown
Due 11 June 1999
Resolved 11 June 1999
Engineering
Issued 11 June 1999
Resolved
DOUBLE NUT CONTROL LINKAGES ON BOTH MDE CLUTCHES.
Condition: Unknown
Due 11 June 1999
Resolved 11 June 1999
Engineering
Issued 11 June 1999
Resolved
REPAIR LAGGING ON BOTH MDE EXHAUSTS.
Condition: Unknown
Due 11 June 1999
Resolved 11 June 1999
Lifesaving
Issued 11 June 1999
Resolved
ADJUST JACKING MECHANISM TO ENSURE ALL LEGS ELEVATE SMOOTHLY.
Condition: Unknown
Due 11 June 1999
Resolved 11 June 1999
Construction/Loadline
Issued 11 June 1999
Resolved
PROVIDE STRAINER ON PORT SIDE E/R BILGE SUCTION LINE.
Condition: Unknown
Due 11 June 1999
Resolved 11 June 1999
Construction/Loadline
Issued 20 March 1998
Resolved
Clean and make available for inspection area on bottom inboard side of starboard fuel tank and hull plating were red hand (filler) has been applied.
Condition: Unknown
Due 20 March 1998
Resolved 23 March 1998
Lifesaving
Issued 20 March 1998
Resolved
Properly install lifefloat painter weaklink, present arrangement will not allow line to pay out.
Condition: Unknown
Due 20 March 1998
Resolved 23 March 1998
Construction/Loadline
Issued 20 March 1998
Resolved
Submit proposal for repair to wasted deck under aft cabin bulkhead and NDT weld in presence of USCG inspector.
Condition: Unknown
Due 20 March 1998
Resolved 23 March 1998
Documentation
Issued 4 May 1990
Resolved
PROVIDE FOR REVIEW AND APPROVAL BY COMMANDANT (G-MSC) THE FOLLOWING PLANS: GENERAL ARRANGEMENTS, INBOARD AND OUTBOARD PROFILES, LEG STRUCTURES, JACKING TOWER STRUCTURES, HYDRAULIC SYSTEMS, AND STABILITY CALCULATIONS.
Condition: Unknown
Due 4 May 1990
Resolved 4 May 1990
Documentation
Issued 4 May 1990
Resolved
PROVIDE FOR REVIEW AND APPROVAL BY COMMANDANT (G-MSC) AN OPERATING MANUAL. THIS WILL INCLUDE LOCATIONS AND REPAIR PROCEDURES FOR ALL HIGH-TENSILE STEEL USED IN VESSEL'S CONSTRUCTION.
Condition: Unknown
Due 4 May 1990
Resolved 4 May 1990
Engineering
Issued 4 May 1990
Resolved
REPLACE ALL PLASTIC SIGHT-GLASS TUBES ON FUEL TANKS WITH TUBES OF HEAT RESISTANT MATERIALS (I.E. PYREX GLASS) ADEQUATELY PROTECTED FROM MECHANICAL DAMAGE, IN ACCORDANCE WITH 46 CFR 58.50-10 (A)(6).
Condition: Unknown
Due 4 May 1990
Resolved 4 May 1990
Fire Fighting
Issued 4 May 1990
Resolved
INSTALL A PERMANENTLY-PIPED, THROUGH-HULL FIREPUMP SUCTION, AND DEMONSTRATEADEQUATE FIREFIGHTING PRESSURE.
Condition: Unknown
Due 4 May 1990
Resolved 4 May 1990
Construction/Loadline
Issued 4 May 1990
Resolved
PROVIDE "DEAD MAN" FEATURE ON CONTROLS FOR JACKING SYSTEM.
Condition: Unknown
Due 4 May 1990
Resolved 4 May 1990