Records from 2016 to 2024. Most recent: inspection, 13 November 2024.
Inspection history · 51
13 November 2024
In-Service Inspection · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8034019
13 November 2024
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8036963
9 February 2024
PSC B
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7857577
7 April 2023
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7664555
7 April 2023
PSC B · Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7664601
2 April 2023
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7661105
10 March 2022
PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7409451
7 June 2021
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7218430
3 June 2021
MARPOL Annex VI Survey · PSC B · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7213422
30 May 2021
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7210015
24 March 2021
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7162097
22 March 2021
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7160618
19 March 2021
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7159241
19 March 2021
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7159330
18 March 2021
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7158432
13 January 2021
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7124065
11 January 2021
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7122688
15 November 2020
Administrative Inspection · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7095432
2 November 2020
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7088607
1 November 2020
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7088054
29 October 2020
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7086591
27 October 2020
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7085231
8 September 2020
PSC B · MARPOL Annex VI Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7052902
18 August 2020
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7036795
17 August 2020
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7035129
14 August 2020
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7032701
6 June 2020
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6969563
2 June 2020
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6967802
29 May 2020
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6963336
29 May 2020
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6963499
21 March 2020
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6929918
17 March 2020
Type not recorded
No type recorded · Maritime Safety & Security Team New York (91106) · Activity 6928185
17 March 2020
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6928321
14 March 2020
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6926658
12 March 2020
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6925576
26 December 2019
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6879619
21 December 2019
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6877600
27 August 2019
ISPS III Exam · NPV Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6795831
28 February 2019
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6634056
23 February 2019
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6631045
11 December 2018
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6596097
10 December 2018
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6594848
25 September 2018
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6548029
25 September 2018
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6548602
21 September 2018
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6545649
14 July 2018
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6478636
12 July 2018
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6476389
9 July 2018
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6472941
9 July 2018
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6472966
22 March 2017
In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6109040
30 December 2016
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6062117
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 November 2024
No resolution recorded
Means shall be provided whereby normal operations of propulsion machinery can be sustained. Special consideration shall be given to the malfuncting of the sources of lubricating oil pressure. PSCO observed no.1 lube oil purifier inoperable.
74SOLAS(04) CH II-1/26.3.5
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 13 November 2024
No resolution recorded
A ship when in a port of another contracting government is subject to control by officers duly authorized by such government concerning operational requirements in respect of the safety of ships, when there are clear grounds for believing that the master or crew are not familiar with essential shipboard procedures relating to the safety of ships. PSCOs received a report of a Lube Oil Spill. Vessel reported that the PIC of the bunkering operations attached the line to the E-Gen L/O storage tank instead of M/E L/O storage tank.
74 SOLAS (20) XI-1/4.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 November 2024 — due date passed with no resolution recorded
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 10 March 2022
Resolved
THE RINGS, LINES AND LETTER SHALL BE PAINTED IN WHITE OR YELLOW ON A DARK BACKGROUNG OR IN BLACK ON A LIGHT BACKGROUND. THEY SHALL BE PERMANTELY MARKED ON THE SIDES OF THE SHIPS TO THE SATISFACTION OF THE ADMINISTRATION. THE MARKS SHALL BE PLAINLY VISIBLE AND, IF NECESSARY, SPECIAL ARRAIGNMENTS SHALL BE MADE FOR THIS PURPOSE. PSCO OBSERVED PORT SIDE LOAD LINE RUSTED AND MISSING PAINT. ICLL 66I/6
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 April 2023
Resolution: Vessel provided a Load Line Certificate assisting to the new Load Lines on the vessel.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 September 2020
Resolved
While conducting test of emergency steering, hydraulic oil was significantly leaking from #3 pump, and constant leaks from #1 and #2 pumps.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 September 2020
Resolved 9 September 2020
Resolution: Vesel replaced seals and conducted repairs to the approval of class.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 8 September 2020
Resolved
Quick closing valve in purifier room was found wedged open with wooded blocks.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 8 September 2020
Resolved 8 September 2020
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 25 September 2018
Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT ANGER TO THE SHIP OR PERSONS ON BOARD. OIL LEAK FROM SCAVENGER AIR DRAIN TANK.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 27 September 2018
Resolved 27 September 2018
Resolution: TIGHTENED NUT THAT WAS LOOSE ON SCAVENGER AIR DRAIN TANK.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 September 2018
Resolved
ELECTRICAL INSTALLATIONS SHALL BE SUCH THAT THE SAFETY OF CREW AND SHIP FROM ELECTRICAL HAZARDS WILL BE ENSURED. LIGHT STRUCTURE ON DECK STBD SIDE AND UP FORWARD, CORRODED AND ONLY HANGING ON BY ONE BOLT.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 October 2018
Resolved 28 September 2018
Resolution: Class sent photos of rectification.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 30 December 2016
Resolved
PSCO did not witness an operational test of the OWS. See narrative for more information.
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 December 2016
Resolved 20 March 2017
Resolution: Documentation submitted to rectify deficiency/uninspected item.