MAURY USCG vessel records Sign in
← All vessels

BAY BRIDGE

BAY BRIDGE is a freight ship. The Coast Guard has recorded 13 inspections since 2011, most recently in July 2026, along with 2 deficiencies and 1 operational control.

Records from 2011 to 2026. Most recent: inspection, 13 July 2026.

Built
Not recorded
Last inspected
13 July 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9463267 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1074480
Flag
PANAMA
—
Maury page id
psix-1074480

Inspections, by type

…with no type recorded2
Years with a record 8 calendar years (2011–2026)
The 13 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it70779 - Displacement, Metric Ton
52118 - Dead Weight, Metric Ton
44234 - Convention (Subpart B), Gross Ton
24146 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 13

13 July 2026 PSC A
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8436957
6 May 2019 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6671816
18 March 2019 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6643164
11 February 2019 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6622717
24 January 2018 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6342562
24 January 2018 Ballast Water Examination · In-Service Inspection · NPV Safety Exam · ISPS III Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6342811
23 January 2018 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6348600
19 May 2017 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6149746
6 May 2016 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5870476
9 October 2014 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5002557
15 March 2014 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4812306
2 February 2012 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4233057
25 January 2011 Random ISPS/MTSA/PSC
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3932208

Deficiency record · 2

Engineering › Diesel Engine (propulsion-direct drive) › Piping (air intake)
Issued 25 January 2011 Resolved
Number 2 Start Air line was found with multiple patches creating a possible loss of propulsion.
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 26 January 2011
Resolved 28 February 2011
Resolution: Received class report from NKK with pictures showing a renewal of the start air line.
Engineering › Steering Gear System › Rudder
Issued 25 January 2011 Resolved
The steering gear system is not functioning properly when using the number 2 pump. The rudder is hunting at amidships and is having hydraulic pressure issue at hard port.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 26 January 2011
Resolved 28 February 2011
Resolution: Received class report from NKK attesting to the steering gear pumps functioning properly after an electrical issue was addressed.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.