MAURY USCG vessel records
← All vessels

ATLAS T

ATLAS T is a 2010 tank ship. The Coast Guard has recorded 17 inspections since 2016, most recently in March 2026, along with 5 deficiencies and 3 operational controls.

Records from 2016 to 2026. Most recent: inspection, 13 March 2026.

Built
2010
Last inspected
13 March 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9441855
V7A4682
1074730
Flag
MARSHALL ISLANDS
Maury page id
psix-1074730

Inspections, by type

…with no type recorded5
Years with a record 8 calendar years (2016–2026)
The 17 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it47987 - Dead Weight, Metric Ton
58000 - Displacement, Metric Ton
28844 - Regulatory (Subpart C or D), Gross Ton
12582 - Regulatory (Subpart C or D), Net Ton
28844 - Convention (Subpart B), Gross Ton
12582 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 17

13 March 2026 COC-TVE Annual · PSC B
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8317402
8 December 2025 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8278224
10 March 2025 COC-TVE Renew
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8090660
8 March 2025 COE-Administrative
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8091136
4 March 2025 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8088069
28 February 2025 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8086095
11 August 2023 COC-TVE Annual · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7765559
10 August 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7764870
8 August 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7763162
1 May 2023 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7678487
1 May 2023 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7683502
18 January 2023 COE-Administrative
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7623430
7 July 2022 COC-TVE Renew · PSC A
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7496953
9 July 2019 ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6743809
29 October 2018 Ballast Water Examination · COC-TVE Annual · ISPS II Exam
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 6567346
7 September 2017 COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 6260368
2 September 2016 COC-TVE Annual · Ballast Water Examination · ISPS III Exam
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 5975570

Deficiency record · 5

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 March 2026 Resolved
The purpose of this regulation is to maintain and monitor the effectiveness of the fire safety measures the ship is provided with. For this purpose, the following functional requirements shall be met; fire protection systems and appliances shall be maintained ready for use. In steering gear room, PSCO observed fire hose not servicable. 74 SOLAS (20) II-2/14.1.1
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 13 March 2026
Resolution: Crew replaced the not servicable hose with an extra new hose.
07 - Fire Safety › N/A - No Subsystem › International shore-connection
Issued 13 March 2026 Resolved
International shore connections... shall be kept aboard the ship together with a gasket of any material suitable for 1 N/mm2 services, together with four bolts of 16mm diameter and 50mm in length, four 16mm nuts and eight washers. PSCO observed four washers oboard. 74 SOLAS (20) II-2/10.2.1.7; FSS Code CH 2/2.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 13 March 2026
Resolution: Crew added four additional washers to the international shore connection for eight total.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 7 July 2022 Resolved
Tankers shall be equiped with atleast one portable instrument for measuring flammable vapor concentration, together with a sufficient set of spares. Suitable means shall be provided for the calibration of scuh instrument. Span Gas expired SEP 2021 (74) SOLAS (09) II-2/4.5.7.1
Action required: 15 - Rectify deficiencies by next port
Resolved 10 July 2022
Resolution: Vessel recieved new span gas w/ expiration date of 07/08/2024. see attachment in documents for further information.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 29 October 2018 Resolved
Doors fitted in boundary bulkheads of machinery spaces of category A chall be reasonably gastight and self-closing. PSCOs foung the door leading into the machinery room to be warped, missing a lock, and would not self close. Cite SOLAS 2014 Ch. II-2 Reg 9.4.2.1 Action 40C
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 31 October 2018
Resolved 10 July 2019
Resolution: Class cleared the DEF.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 October 2018 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. A few inches of water was discovered in the emergency fire pump space. PSCOs ran the pump and the water did not appear to accumulate but was unable to drain due to spring loaded plug failure. Cite: SOLAS 2014 CH1 Reg 11 (a) Action: 40a
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 31 October 2018
Resolved 10 July 2019
Resolution: Class cleared the DEF.

Ownership record