MAURY USCG vessel records Sign in
← All vessels

PINE EXPRESS

PINE EXPRESS is a 2010 tank ship. The Coast Guard has recorded 8 inspections since 2014, most recently in November 2023, along with 3 deficiencies and 1 operational control.

Records from 2014 to 2023. Most recent: inspection, 22 November 2023.

Built
2010
Last inspected
22 November 2023
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9405928 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1075984
Flag
HONG KONG
—
Maury page id
psix-1075984

Inspections, by type

Years with a record 6 calendar years (2014–2023)
The 8 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it56880 - Displacement, Metric Ton
46710 - Dead Weight, Metric Ton
28985 - Convention (Subpart B), Gross Ton
12241 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 8

22 November 2023 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7828742
31 October 2023 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7815613
27 October 2022 PSC B · COC-CHEM & TVE Annual
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7585018
10 October 2021 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7328698
30 September 2019 ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6818231
17 August 2015 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5218568
15 August 2014 In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4955492
13 May 2014 ISPS II Exam · Ballast Water Examination · COC-CHEM Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4856736

Deficiency record · 3

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 31 October 2023 Resolved
The purpose if this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met: means shall be provided to control leaks of flammable liquids. PSCO observed fuel leaks on #1, #2 and #3 fuel strainers on Ships Service Diesel Generators. 74 SOLAS 2020 II-2/4.1.1 60ac
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 31 October 2023
Resolved 31 October 2023
Resolution: O-rings were replaced to stop the fuel leaks on the strainers. All three (3) generators were operationally tested to the satisfaction of the attending surveyor.
Engineering › Steering Gear System › Motor
Issued 15 August 2014 Resolved
74SOLAS(2009) CH II-1/Reg 29.16.2 The main steering gear shall comprise either two independent and separate power actuating systems or at least two identical power actuating systems. The Vessel's number 1 steering motor has burnt out. Vessel only has 1 working steering system. To be rectified prior to departure from port and to the satisfaction of class.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 August 2014
Resolution: Vessel replaced #1 steering motor and system tested by class. Motor operates properly and vessel now has 2 working steering systems.
Fire Fighting › Fixed Fire Detection System › Manually Operated Call Points
Issued 13 May 2014 Resolved
Vessel has installed fixed gas detection system in voids & ballast tanks. Ship unable to demonstrate proper operation of either low flow or H2S & LEL with span gas.
Condition: Placed in Improper Service
Action required: 15 - Rectify deficiencies by next port
Resolved 7 June 2014
Resolution: Vessel submitted documentation attesting proper operation.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.