MAURY USCG vessel records
← All vessels

KARVUNA

KARVUNA is a 2010 freight ship. The Coast Guard has recorded 9 inspections since 2018, most recently in November 2023, along with 2 deficiencies and 3 operational controls.

Records from 2018 to 2023. Most recent: inspection, 7 November 2023.

Built
2010
Last inspected
7 November 2023
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 7 November 2023
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2018–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9468619
9HA2055
1076300
Flag
MALTA
Maury page id
psix-1076300

Documentation record

Tonnage as PSIX records it27989 - Displacement, Ton
21179 - Dead Weight, Ton
13965 - Convention (Subpart B), Gross Ton
7244 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 9

7 November 2023 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7815972
24 February 2023 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7641596
4 May 2022 Deficiency Check · PSC B · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7440826
30 May 2021 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7207119
2 November 2020 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7088297
1 November 2020 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7087778
24 October 2018 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6567110
21 October 2018 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6565526
16 October 2018 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6562607

Deficiency record · 2

02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 7 November 2023 Resolved
The utilization of other flammable oils employed under pressure in power transmission systems shall be as such as to ensure the safety of the ship and persons on board. PSCO observed leak on #2 steering gear pump. On announcement to crew it was repaired and brought back into proper operational condition. 74 SOLAS (2020) II-2/4.2.4 10 c
Action required: 10 - Deficiency Rectified
Due 7 November 2023
Resolved 7 November 2023
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 4 May 2022 Resolved
07124-Maintenance of fire protection systems-Maintenance, testing and inspections shall be carried out based on the guidelines developed by the organization and in a manner having due regard to ensuring the reliability of fire fighting systems and appliances. PSCO observed vessel did not have proper testing equipment for the flame detector and heat detector as per manufacturer -74SOLAS(04) II-2/14.2.2.1 -40AC.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 4 May 2022
Resolved 11 May 2022
Resolution: Received evidence from company DPA allowing the use of cigarette lighters and heat guns for onboard testing of fire detecting systems.

Ownership record