MAURY USCG vessel records
← All vessels

SYROS TRADER

SYROS TRADER is a 2008 freight ship. The Coast Guard has recorded 4 inspections since 2018, most recently in March 2025, along with 2 deficiencies.

Records from 2018 to 2025. Most recent: inspection, 13 March 2025.

Built
2008
Last inspected
13 March 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9395214
1077091
Flag
LIBERIA
Maury page id
psix-1077091

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspections, by type

Years with a record 3 calendar years (2018–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it36353 - Convention (Subpart B), Gross Ton
63708 - Displacement, Ton
53408 - Dead Weight, Ton
21607 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 4

13 March 2025 PSC B · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8093039
3 October 2023 Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7802398
25 September 2023 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7797719
22 May 2018 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6410431

Deficiency record · 2

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 13 March 2025 Resolved
THE FOLLOWING FUNCTIONAL REQUIREMENTS SHALL BE MET: FIRE PROTECTION SYSTEMS AND FIREFIGHTING SYSTEM AND APPLIANCES SHALL BE MAINTAINED, READY FOR USE. PSCO OBSERVED DETERIORATION OF CO2 LINES LEADING TO CARGO HOLDS. 74SOLAS(20)II-2/14.1.1 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 March 2025
Resolved 17 March 2025
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 13 March 2025 Resolved
SETTLING OR DAILY SERVICE TANK HAVING A CAPACITY OF 500L AND ABOVE SHALL BE FITTED WITH A COCK OR VALVE DIRECTLY ON THE TANK CAPABLE OF BEING CLOSED FROM A SAFE POSITION OUTSIDE THE SPACE. PSCO OBSERVED TEMPORARY REPAIR ON REMOTE FUEL SHUT OFF CABLE FOR EMERGENCY GENERATOR FUEL TANK. 74SOLAS(20)II-2/4.2.2.2.3.4 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 March 2025
Resolved 17 March 2025

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.