MAURY USCG vessel records Sign in
← All vessels

SYROS TRADER

SYROS TRADER is a 2008 freight ship. The Coast Guard has recorded 5 inspections since 2014, most recently in March 2025, along with 3 deficiencies.

Records from 2014 to 2025. Most recent: inspection, 13 March 2025.

Built
2008
Last inspected
13 March 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9395214 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1077091
Flag
LIBERIA
—
Maury page id
psix-1077091

Inspections, by type

Years with a record 4 calendar years (2014–2025)
The 5 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it36353 - Convention (Subpart B), Gross Ton
63708 - Displacement, Ton
53408 - Dead Weight, Ton
21607 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 5

13 March 2025 PSC B · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8093039
3 October 2023 Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7802398
25 September 2023 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7797719
22 May 2018 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6410431
18 June 2014 NPV Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4888023

Deficiency record · 3

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 13 March 2025 Resolved
THE FOLLOWING FUNCTIONAL REQUIREMENTS SHALL BE MET: FIRE PROTECTION SYSTEMS AND FIREFIGHTING SYSTEM AND APPLIANCES SHALL BE MAINTAINED, READY FOR USE. PSCO OBSERVED DETERIORATION OF CO2 LINES LEADING TO CARGO HOLDS. 74SOLAS(20)II-2/14.1.1 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 March 2025
Resolved 17 March 2025
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 13 March 2025 Resolved
SETTLING OR DAILY SERVICE TANK HAVING A CAPACITY OF 500L AND ABOVE SHALL BE FITTED WITH A COCK OR VALVE DIRECTLY ON THE TANK CAPABLE OF BEING CLOSED FROM A SAFE POSITION OUTSIDE THE SPACE. PSCO OBSERVED TEMPORARY REPAIR ON REMOTE FUEL SHUT OFF CABLE FOR EMERGENCY GENERATOR FUEL TANK. 74SOLAS(20)II-2/4.2.2.2.3.4 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 March 2025
Resolved 17 March 2025
Operations/Management › Drills/Instruction › Not Conducted
Issued 18 June 2014 Resolved
9900-Other-The response plan must address the exercise program to evaluate the ability of the vessel to perform the identified functions in the plan. Crew did not conduct the QI notification exercise upon entry to US waters as required by their VRP plan. Provide corrective action plan from the company. 33 CFR 155 50c
Action required: 705 - Other - as specified
Due 17 July 2014
Resolved 16 July 2014
Resolution: PSC NOLA received corrective action plan from company satisfying the requirement.

Ownership record