Records from 2011 to 2022. Most recent: inspection, 15 September 2022.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
11 - Life Saving Appliances › N/A - No Subsystem › Means of recovery of life saving appliances
Issued 15 September 2022
Resolved
Recovery time of rescue boat shall be not more than 5 minutes in moderate sea conditions when loaded with its full complement of persons and equipment.
Limit switch failed, causing starboard rescue boat to be recoverable using only the hand crank and greater than 5 minutes.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 September 2022
Resolution: Rectified prior to completion of exam. Code 10c issued.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 15 September 2022
Resolved
The side ropes of the embarkation ladder shall consist of two uncovered manila ropes not less than 65mm in circumference on each side.
Side ropes of forward embarkation ladder are wasted and parting.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 September 2022
Resolution: NKK class society approved actions of vessel. Vessel is set to recieve new ladder at next port at Vancouver B.C. See attached document for further details.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 15 September 2022
Resolved
74SOLAS(20) II-2/9.2.3.4.1
Stairways which penetrate only a single deck shall be protected by a self-closing door.
"B" deck stairwell self-closing door did not close.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 15 September 2022
Resolution: Crew performed maintenance on self-closing device, door was deemed to be fully operational prior to completion of exam.
Lifesaving › Launching Appliances › Davit
Issued 7 October 2015
Resolved
0610 The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Before the ship leaves port and at all times during the voyage, all life saving appliances shall be in working order; See Narrative.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 October 2015
Resolved 9 October 2015
Resolution: Corrected and tested to the satisfaction of Class.
Operations/Management › Drills/Instruction › Fire
Issued 7 October 2015
Resolved
0925 Every crew member with assigned duties shall be familiar with these duties before the voyage begins. Crew failed 2 consecutive fire drills. During the first fire drill, crew did not properly don PPE and did not set fire boundaries. During the second drill, members entered the area of fire without PPE and fire fighters donned equipment improperly. 74 SOLAS (14)I/19 74 SOLAS (14)III/19.2.1.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 October 2015
Resolved 12 October 2015
Resolution: [name withheld] witnessed a suscessful Fire Drill.
Engineering › Sea-water System (primary cooling) › Piping
Issued 7 October 2015
Resolved
After any survey of the ship has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey, without the sanction of the Administration. The following items were found in the Engine Room. 1, F/W generator pipe patched in four places. 2, M/E Cooling S/W pump supply line patched. 3, Bilge eductor patched; See Narrative.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 October 2015
Resolved 9 October 2015
Resolution: Corrected to the satisfaction of Class.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 7 October 2015
Resolved
1730; After any survey of the ship has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey, without the sanction of the Administration. The Oily Water Separator was patched by the crew on or about 25 September 2015. None of the crewmembers have welding certificates, 74 SOLAS (14) Cons. Ch. I/11 (b).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 October 2015
Resolved 9 October 2015
Resolution: Corrected and tested to the satisfaction of Class.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 7 October 2015
Resolved
0735; In close proximity to the helideck in addition to the requirements of Reg., 10.10 two sets of fire-fighting outfits shall be provided and stored near the means of access to that helideck. Vessel does not have additional two fire-fighting outfits. Note; Hatch #5 has a symbol for a helideck, but it is not listed on the fire plan and the crew practice drills on a regular basis, See Narrative.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 October 2015
Resolved 9 October 2015
Resolution: Corrected to the satisfaction of Class.
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 6 October 2015
Resolved
2510; Vessel must maintain a Ballast Water and Bio-Fouling Management plans specifically for the vessel that will allow those responsible for the plan to understand and follow it. Vessel currently has an incomplete Ballast Water Management Plan, which the crew has not followed and there is no Bio-Fouling Plan for this vessel, 33CFR151.2050(g, MEPC 207(62).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 October 2015
Resolved 9 October 2015
Resolution: Addressed and corrected to the satisfaction of Class.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 6 October 2015
Resolved
0750; The minimum fire integrity of bulkheads shall be as prescribed in tables 44.1 and 44.2. Natural Air Vents (13) around the main accommodation house were found non-operational, 74 SOLAS (01) Cons. II-2/44.1.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 October 2015
Resolved 7 October 2015
Resolution: All air vents were repaired by the ship's crew prior to leaving the vessel.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 21 July 2011
Resolved
Contracting Government shall ensure that, from a point of view of life at sea, all ships shall be sufficiently and effectively manned. The endorsements of the chief engineer and second engineer do not correspond with their certificate of competency . The Vessel shall provide documentation attesting to the full compliance with the safe manning certificate prior to departure from Port Arthur 17bc
Action required: 705 - Other - as specified
Due 21 July 2011
Resolved 22 July 2011
Resolution: Vessel received documentation from Panama attesting to the validity of the Chief and Second engineers endorsements and the deficiency was removed. the vessels form B hold was removed and the vessel is cleared with no restrictions.